Resumen del contenido incluido en la página 1
ADDENDUM
Addendum No. C3409M
Date December 22, 2005
Manuals Affected C2462M-B, C2403M-C, C2410M-H,
C2491M-B, C2496M
Manual Update Switch Settings for Varifocal Lens
Manual Update The high resolution camera with vari-
focal lens and auto iris is configured at
the factory for automatic exposure.
SWITCH SETTINGS FOR VARIFOCAL LENS
The high resolution camera with varifocal lens and auto iris is configured at the factory for
automatic exposure.
1 AWB Automatic white balance
FACTORY SETTINGS
2 GA
Resumen del contenido incluido en la página 2
INST ALLA TION ® 310 Series Camclosure Integrated Camera System C2496M (10/05)
Resumen del contenido incluido en la página 3
Resumen del contenido incluido en la página 4
Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 5
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 7. Only use attachments/accessories specified by the manufacturer. 8. Use only with the cart, stand, tripod, bra
Resumen del contenido incluido en la página 6
REGULATORY NOTICES This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC, Class A (black-white, EIA and CCIR cameras – except auto iris models) RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class
Resumen del contenido incluido en la página 7
Description ® The 310 Series Camclosure integrated camera system is a track-light design that mounts to a wall or ceiling. The system incorporates a camera and lens package into a small, unobstructive, medium- security enclosure designed for areas subject to vandalism. The system is quick and easy to install in a variety of indoor or outdoor applications. It is ideal for residential, office, mall, hospital, school, parking garage, correction and detention, and other medium-securi
Resumen del contenido incluido en la página 8
WALL OR CEILING • Mounting to ICS310-COND conduit adapter (not supplied) CONDUIT ADAPTER TWO-GANG ELECTRICAL BOX WALL OR CEILING • Mounting to a two-gang electrical box ICS310-AP ADAPTER PLATE (NOT SUPPLIED) 6-32 X 0.50 SECURITY SCREW (SUPPLIED WITH ADAPTER PLATE) C2496M (10/05) 7
Resumen del contenido incluido en la página 9
CONNECT VIDEO AND POWER 1. Some indoor installations do not require a heater. If the installation does not require a heater, disconnect the heater wiring. a. Remove the cover with the supplied 1/8-inch hollow screwdriver bit. b. Remove the camera from the mounting bracket, and unplug the four-pin heater connector in the base. The connector has orange, red, and black wires. c. Reinstall the camera. If the camera has a varifocal lens, leave the cover off; it will be reinstalled later. O
Resumen del contenido incluido en la página 10
ATTACH BASE Release the base locking ring for access to the mounting holes. To attach the base to an adapter plate or conduit adapter, two 6-32 x 1.25-inch tamper-resistant screws are supplied with the adapters. Use the 1/8-inch hollow screwdriver bit supplied with the Camclosure. Mounting hardware for all other applications is not supplied. ADJUST ENCLOSURE Turn on power to the camera and monitor. Release one or both locking rings, swivel the enclosure until the angle of the camera is
Resumen del contenido incluido en la página 11
Adjustments (Color Camera Only) If you have a color camera, it is set up at the factory and normally requires no adjustments. Sometimes, however, adjustments may be necessary. 1. Remove the cover using the supplied 1/8-inch hollow screwdriver bit. 2. Adjust the vertical phase, iris level, focus, or switch settings (refer to procedures below). 3. Reseat the O-ring on the cover and reinstall the cover. VERTICAL PHASE (24 VAC OPERATION ONLY) Adjustment is required if there is vertical roll
Resumen del contenido incluido en la página 12
SWITCH SETTINGS FOR VARIFOCAL LENS The high resolution camera with varifocal lens and auto iris is configured at the factory for optimal performance in lighting conditions where auto iris is required. It is also configured with the shutter speed set at 1/60 (NTSC) or 1/50 (PAL) and manual gain set at 6 dB. 1AWB Automatic white balance 2 GAM Gamma function FACTORY SETTINGS 3 AGC Automatic gain control 12345678 4 ESC Electronic shutter control UP DOWN 5 BLC Backlight compensat
Resumen del contenido incluido en la página 13
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fi xed lighting conditions where there are no bright spots that darken other picture details. Manual backlight compensation is used in fixed lighting conditions to optimize the picture detail when there are bright spots. FACTORY SETTINGS ALC/
Resumen del contenido incluido en la página 14
FOCUS ADJUSTMENT FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS WARNING: Heater elements could be hot! When camera power is on, use caution when adjusting the camera. To adjust the focus, it may be necessary to remove the heater board in order to loosen the locking screw on the bottom of the lens. To remove the heater board: HEATER BOARD 1. Disconnect the four-pin heater wiring. 2. Wait for the heater elements to cool if they are hot. 3. Press on an end of the board. To adjust the focus
Resumen del contenido incluido en la página 15
Specifications General Pan/Tilt Adjustment Manual; 180° pan; 180° tilt Construction Aluminum base and cover, steel camera mounting bracket Finish Gray polyester powder coat Environment Low temperature, indoor/outdoor Operating Temperature -50° to 122°F (-46° to 50°C); de-ices to -10°F (-23°C) Heater Turns on at 50°F (10°C) and off at 80°F (27°C) Unit Weight 1.45 lb (6 kg) Electrical Input Voltage 12 VDC or 24 VAC, ±10% Power Consumption 13 watts or less Video Connector BNC 7.14 (18.14
Resumen del contenido incluido en la página 16
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. ® • Three years on Genex Series products (multiplexers, server, and keyboard). ® • Three years on Camclosure and fixed camera models, except the CC3701H-2,
Resumen del contenido incluido en la página 17
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO9001 United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East | | | | | | | |