SYSTEM OVERVIEW ...............................................................................................................................3 Features ..................................................................................................................................................3 General Operation ..................................................................................................................................5 Quick View of System
Resumen del contenido incluido en la página 3
Features General Information This system offers you three forms of protection: burglary, fire, and emergency, depending on the configuration of your system. The system consists of a master keypad for controlling system operation, various wireless sensors that provide perimeter and interior burglary protection, and optional smoke or combustion detectors to provide early fire warning. In addition, optional wireless keypads may have been installed to allow you to control the
Resumen del contenido incluido en la página 4
Features • Two-way voice: Allows the central station to listen, talk to or conduct two-way conversations with individuals on the premises Refer to the TWO-WAY VOICE section for detailed information. • Phone Control: Provides a remote interactive phone capability that permits access to the security system from any off-site touch-tone telephone. • Speaker Phone Operation: The system is capable of operating as a speaker phone allowing hands free telephone conversation. • Se
Resumen del contenido incluido en la página 5
General Operation Zones Your system's sensing devices have been assigned to various "zones." For example, the sensing device on your entry/exit door may have been assigned to zone 01, sensing devices on windows in the master bedroom to zone 02, and so on. These numbers appear on the display when an alarm or trouble condition occurs. ReadyGuard-REN is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC) is insta
Resumen del contenido incluido en la página 6
General Operation announcements of the zones in alarm begins. When these zones have been announced, the siren sounds again and the cycle repeats itself, until the system is disarmed (code + OFF) or until alarm bell timeout occurs. If your system is connected to a central monitoring station, an alarm message will be sent. To stop the alarm sounding, simply disarm the system. The zone(s) causing the alarm remain displayed indicating memory of alarm. Refer to the DISARMING T
Resumen del contenido incluido en la página 7
NOTE: = Boxes represent the entering of your 4-digit user code. SECURITY FUNCTIONS Checking system status: ---------------------- STATUS * To arm in STAY mode: --------------------- + STAY To restart exit delay: ------------------------- STAY (only if programmed and system armed in Stay mode) * To arm in AWAY mode: -------------------- + AWAY * To arm with NO DELAY: ------------------
Resumen del contenido incluido en la página 8
REMOTE PHONE CONTROL OPERATION To remotely disarm: -------------------------- + [1] To remotely arm in AWAY mode: [2] --------- + To remotely arm in STAY mode: ---------- + [3] To remotely arm in AWAY or STAY mode with NO DELAY: + [2] or [3] + [0] To remotely activate X-10 devices 1-6: --- [#] + [4] + device no. To remotely activate X-10 devices 7 & 8:
Resumen del contenido incluido en la página 9
About the Master Keypad General IMPORTANT: If the keypad beeps rapidly upon entering the premises, an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location. The keypad allows you to control all system functions. In the speaker phone mode the keypad becomes a full-function telephone keypad The keypad features telephone-style keys and a Liquid Crystal Display (LCD), wh
Resumen del contenido incluido en la página 10
Master Keypad Definitions 21 1 2 3 20 4 19 5 ARMED READY 6 OFF 12 3 RECORD VOLUME PLAY 18 7 AWA Y 45 6 LIGHTS ON TEST BYPASS STAY 78 9 LIGHTS OFF CODE CHIME 8 17 AUX 0 # * STATUS NO DELAY FUNCTION 9 16 11 14 12 10 15 13 01100-007-V0 IMPORTANT!: When you use the keypad to enter codes and commands, press the keys within 2 seconds of one another. If 2 seconds elapse without a key depression, the entry is aborted and must be repeated from its beginning. NOTE:
Resumen del contenido incluido en la página 11
Master Keypad Definitions NOTE: The system functions described below are for reference only, and require additional key entries to activate. 1. DISPLAY WINDOW: Liquid Crystal Display 13. LIGHTS ON / LIGHTS OFF KEYS: Turns lights or (LCD). Displays protection point identification and other devices on or off, if programmed by the installer. system status, messages, and user instructions. 14. AUX KEY: Can be programmed to either perform a 2. ARMED INDICATOR: (RED) L
Resumen del contenido incluido en la página 12
About the Display and Indicators LOW BAT AC AWAY INSTANT CHIME TEST REC MESSAGE STAY (for other displays, see Trouble Messages) ALARM FIRE BYPASS FAULT Display Definitions ALARM: Appears when the system is armed and an intrusion has been detected (also appears during a fire alarm or audible emergency alarm). Accompanied by the protection zone that is in alarm. AWAY: All burglary zones, interior and perimeter, are armed. INSTANT: Entry delay is turned off. P
Resumen del contenido incluido en la página 13
Checking System Status General Information Before arming your system, all protected doors, windows, and other protection zones must be closed or bypassed (see the BYPASSING PROTECTION section). Pressing the STATUS key will announce all zones that are faulted, as well as any other abnormal system condition, making it easier for you to secure any open zones. READY LIGHT: The green READY indicator on the keypad will be lit if the system is ready to be armed. If bli
Resumen del contenido incluido en la página 14
Arming the System Arming in Stay Mode Use this mode when you are staying home, but expect someone to use the entrance door later. Close all protected perimeter windows and doors before arming. The green READY indicator on the keypad should be lit if the system is ready to be armed. ** or press and hold To arm in STAY mode: + STAY STAY Your User code** ** See Quick Arming paragraph. The keypad beeps three times and displays the armed S
Resumen del contenido incluido en la página 15
Arming the System Arming the System With No Delay Use NO DELAY with STAY mode when you are staying home and do not expect anyone to use the entrance door. Use NO DELAY with AWAY mode when the premises will be vacant for extended periods of time such as vacations, etc. When armed with NO DELAY, the system will sound an alarm if a protected door or window is opened, including the entrance door. You may leave through the entrance door during the exit delay peri
Resumen del contenido incluido en la página 16
Entry/Exit Delays Exit Delay Exit delay begins immediately after arming the system, and gives you time to leave through the designated exit door without setting off an alarm. A slow beeping will sound throughout the exit delay period, if programmed. Exit Alarms Exit Alarm Active To minimize false alarms sent to the alarm monitoring company, your system may have been programmed for this feature. Ask your installer if Exit Alarm is active for your system.
Resumen del contenido incluido en la página 17
Disarming the System Use the OFF key to disarm the system and to silence alarm and trouble sounds. See the SUMMARY OF AUDIBLE NOTIFICATION section for information, which will help you to distinguish between fire and burglary alarm sounds. IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the k
Resumen del contenido incluido en la página 18
Bypassing Protection Zones Bypassing Individual Zones Use the BYPASS key when you want to arm your system with one or more zones intentionally unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. Bypasses are also removed if the arming procedure that follows the bypass command is not successful. The system will not allow f
Resumen del contenido incluido en la página 19
Panic Keys / Chime Mode Panic Keys Your system may have been programmed to use special keys to manually activate panic functions. The functions that might be programmed are listed below. See your installer for the function(s) that may have been programmed for your system. Active Panic Functions Your installer should Keys Zone Function note the functions that 1 and ✴ 95 are active in your 3 and # 96 system. ✴ and # 99 To use a paired key panic function, simp
Resumen del contenido incluido en la página 20
Paging Feature Automatic Paging If the Paging feature has been programmed for your system, your pager will respond to certain conditions as they occur in your system by displaying a message that indicates the type of condition that has occurred. The message appears in a 7-digit format explained below. The system can also be programmed to send up to 16 additional digits that will appear in front of the 7-digit message. These 16 digits may consist of a PIN number or special d