Resumen del contenido incluido en la página 1
®
GE Monogram
Installation
Instructions
Professional
Vent Hoods
48" Models
ZV881WSS, ZV891YSS
ZV880WSS, ZV890YSS
36" Models
ZV671WSS, ZV681YSS
ZV670WSS, ZV680YSS
30" Models
ZV370YSS,
ZV371YSS
Resumen del contenido incluido en la página 2
Before you begin—Read these instructions completely and carefully. IMPORTANT: Save these instructions for local inspector’s use. IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INSTALLER: Be sure to leave these instructions with the Consumer. NOTE TO CONSUMER: Keep these instructions with your Use and Care Book for future reference. This appliance must be properly grounded. See “Electrical Supply”, page 5. WARNING CAUTION If you have questions concerning the installa- TO REDUCE TH
Resumen del contenido incluido en la página 3
Design Information Professional Vent Hoods These hoods can be installed into a soffit, or 48" Wide Models: Models when there is no soffit, they can be installed ZV881WSS, ZV880WSS – with tapered sides Available directly onto a wall. ZV891YSS, ZV890YSS – with straight sides 36" Wide Models: 48" and 36" wide models are available with ZV671WSS, ZV670WSS – with tapered sides different appearances. Model numbers with ZV681YSS, ZV680YSS – with straight sides “YSS” have straight sides. Model numbers en
Resumen del contenido incluido en la página 4
Design Information Professional Vent Hoods These vent hoods must be installed 30" Min. The rating plate is located behind filter Product and 36" Max. above the cooking surface. cutouts. To verify your model number, remove Dimensions Installation will be easier if the vent hood filters. is installed before the range or cooktop & Clearances installation. 12" 12" 35" 47-7/8" 18" 18" 25" 47-7/8" ZV881WSS, ZV880WSS 25" 47-7/8" ZV891YSS, ZV890YSS 12" 12" 35-7/8" 23" 18" 18" 35-7/8" 25" 35-7/8" 25" ZV6
Resumen del contenido incluido en la página 5
Design Information Professional Vent Hoods Installation Framing for adequate support Ductwork planning Advance These vent hoods are heavy. Adequate struc- • Determine the exact location of the vent hood. Planning tural support must be provided. Hoods must be • Plan the route for venting exhaust to the secured to vertical studs or to studs in the outdoors. soffit. • Use the shortest and straightest duct route • Additional studs may be required for a soffit possible. For satisfactory performance
Resumen del contenido incluido en la página 6
Installation Preparation Professional Vent Hoods Use this chart to Total Duct compute maximum Equivalent Quantity Equivalent fittings permissable lengths Duct Piece Dimensions Length* Used Length for duct runs to Round, 1 ft. outdoors. straight (per foot length) Note: Do not exceed maximum 3-1⁄4" x 12" or 1 ft. permissable equivalent lengths! 3-1/4" x 24" (per foot straight length) Maximum duct length: 100 foot for range hoods. 90° elbow 15 ft. Flexible ducting: If flexible metal 45° elbow 9 ft.
Resumen del contenido incluido en la página 7
Installation Professional Vent Hoods Wall Mount Installation: • Tape measure Tools & • Six, 5/16" lag screws, 2" long with washers, • Spirit level Materials all models (provided). • Wire Cutter • Wire stripper Required Soffit Installation: • Electric drill (not supplied) • Six, 5/16" lag screws, 2" long with washers, and appropriate bits all models (provided). • Torx screwdriver Optional for wall mount installations: (See page 9) • 120V 60Hz 15 or 20 Amp, 2 wire with • 48" x 18" plywood for 48"
Resumen del contenido incluido en la página 8
“A” “A” Hood Width Installation Professional Vent Hoods Locate the hardware accessory box packed with range hood and check contents. Step 2 Check Filter(s) Installation Grease Heat Lamp(s) Halogen Hardware Tray(s) (on some models) Bulbs We recommend that the vent hood and/or duct cover be on site before Step final framing and wall finishing to 3 more accurately locate the ductwork and electrical service. Construct NOTE: If the top of the installation Soffit location does not meet the soffit,
Resumen del contenido incluido en la página 9
Installation Professional Vent Hoods 7" Min. (30" and 36" Models) 10" Min. (48" Models) NOTE: A decorative duct cover is available for wall mount installations. The duct cover Step conceals the duct run from the top of the 3A hood to the ceiling. Choose the 6" or 12" cover based upon installation height of the Construct vent hood. Hood Wall Mount Width We recommend that the vent hood and Framing decorative duct cover be on site before final WALL MOUNT framing and wall finishing in order to acc
Resumen del contenido incluido en la página 10
Installation Professional Vent Hoods • Drill 3/16" pilot holes through the shims and Step into the soffit studs. • Hold the hood against the soffit and secure SOFFIT INSTALLATION 4 with 6 lag screws with washers. Install Hood • For additional support and to minimize vibration during operation, we recommend Below Soffit that the hood be secured to the back wall. • Drive lag screws through the rear panel of INSTALLATION the hood and into the wall studs. UNDER A SOFFIT (SKIP THIS STEP IF SOFFIT IS
Resumen del contenido incluido en la página 11
Installation Professional Vent Hoods WALL MOUNT INSTALLATION • Drill 3/16" pilot holes, approximately 1-1/2" Step deep, in all mounting screw locations. Ceiling • Hold the hood in position and drive lag 4A screws in top left and right mounting holes. Install Hood NOTE: 5/16" hanger bolts can be used in the Onto Wall two top locations. Place the hood onto the hanger bolts and secure with nuts and washers. WALL MOUNT INSTALLATION • Install lag screws with washers in remaining (SKIP THESE mounting
Resumen del contenido incluido en la página 12
Installation Professional Vent Hoods • Connect white lead to branch circuit white Verify that power is turned off at the source. lead. CAUTION WARNING Step • Connect black lead to branch circuit black If house wiring is not 2-wire with a 5 lead. ground wire, a ground must be • Connect green lead to branch circuit green Connect provided by the installer. or bare ground lead. When house wiring is aluminum, Electrical • Secure all connections with wire nuts on be sure to use U.L. approved anti- eac
Resumen del contenido incluido en la página 13
Installation Professional Vent Hoods “WSS” Duct Covers • Fasten the duct cover to the top of the hood Step with 2 screws. 8 Install Duct Cover Secure with Screws “YSS” Duct Covers • Install one side piece to the top of the hood with 2 screws. Install opposite side piece. • Secure front panel to the side panels with 2 torx screws on each side (provided). • Place the filter drip trays into the bottom of the opening. Step 9 Install Filters • Grasp the filter by handles, tip the top portion into the
Resumen del contenido incluido en la página 14
Notes Professional Vent Hoods 14
Resumen del contenido incluido en la página 15
Notes Professional Vent Hoods 15
Resumen del contenido incluido en la página 16
Note: While performing installations described in this book, safety glasses or goggles should be worn. To obtain specific information concerning any ® Monogram product or service, call GE Answer Center consumer information service at 800.626.2000—any time, day or night. For Monogram local service in your area, call 1-800-444-1845. Pub. No. 49-8816-1 NOTE: Product improvement is a continuing endeavor at General Dwg. No. 164D3333P060 ® Electric. Therefore, materials, appearance and specifications