_BLE OF (IION]_ENT$ ' .... wm-I IB_]:ELLIC ,.Os_E I .....
BI_:0o0o0 ,.o1_:t0 BOLy..,.o°0.s, SEI/_:::_
Safety Information ...................... 2
Important Installation Instructions ...... 2
For 7' 6" Doors, Extension Kit is available for 8' Doors
Safety Features ......................... 2
included Wall Control MUST be installed prior to Operation
Pre-installation Checklist ................ 3
of this Garage Door Operator,
Garage Door Opener Assembly ......... 9
Safe-T-Beam ® Safety R
Resumen del contenido incluido en la página 2
Garage Doors are heavy objects thatmove withthehelp ofsprings Ifyouhave garage door related questions ordonotunderstand the under high tension andelectric opening equipment. Since moving information presented, callyour nearest Genie Factory Authorized objects, springs under tension, and electric opening equipment Dealer listed atwww.geniecompany.com, orcustomer Service at 1-800-35-GENIE.. may cause injuries, your safety andthesafety ofothers depend on youreading and understanding theinformation
Resumen del contenido incluido en la página 3
WARNING: This Opener includes parts and supplies needed to install in most garages and If your door sticks,binds,or is out of connect to most garage doors. There are many variations of garages and garage balance,haveit adjusted by a GenieFactory doors. A few additional parts and supplies may be needed to install Opener into Authorized Dealer. Door springs,cables, your garage and connect to your garage door. While checking items listed pulleys,bracketsand associatedhardware below, note any additi
Resumen del contenido incluido en la página 4
Rail Extension for 8' door Measure garage door height (7'-6", 8'-0", or taller) with tape measure. A If door height is 7'-6" or less,continue with Check Step 4. B If your door height is above 7'-6%make sure your rail is long enough to open the garage door. If there is any question contact your Customer Service Representative at 1-800-3S-GENIE. Figure 3 Rail Extension Kit CH CKDOOR t_ AD R SECTIONAL DOOR NOTE The header is a heavily reinforced section of the wall just above the top of the garage
Resumen del contenido incluido en la página 5
120 Volt grounded outlet 4_ or wiring box within 3 feet of °"f_ Power Head. Check ceiling or space above where Opener Power Head will be mounted (Figure S): A Measure from garage door center line mark toward rear of garage: • Approximately 10' back if garage has a 7' 6" door. • Approximately 11' back if garage has an 8' 0" door. • Approximately 13' back if garage hasan 10'0"door. • Approximately 14' back if garage hasan 12'0"door. I IIIi "1 II NOTE Mounting Straps are included to attach the Open
Resumen del contenido incluido en la página 6
MOUF_ FIF_G _}RACiKE I" LOC£T OIU Check for wood garage frame, jamb, or masonry at mounting location (6" above floor) with attachment tabs facing away from garage door (Figure 7). A If you cannot mount Safe-T-Beam ®Mounting Bracket to wood frame: _3 Sensor • Concrete screws and concrete anchors (not included) must be used to mount Brackets on masonry with attachment tabs facing away from garage door. • Safe-T-Beam ®Mounting Bracket Extensions may be used (not included - available from a Genie Fa
Resumen del contenido incluido en la página 7
L st item Part Name Quantity Required 1-Pc Rail 13-Pc Rail 1 Power Head Assembly (main carton) 1 1 2 1/4"-20 x 13/16" HexHead Shoulder Bolt (blue bag) 2 2 (yellow bolt) 3 RailAssembly (1 piece#packaged separately) 1 4 RailAssembly (3 piece)(main carton) 1 4A First RailSection 1 4B Middle RailSection 1 4C End RailSection 1 8 1/4"-20 Hex Serrated FlangeNut (blue bag) 4 4 9 RailClamps(blue bag) 4 10 5/16"-18 x 11/16" Hex HeadShoulder Bolt (blue bag) 8 11 5/16"-18 Hex Serrated Flange Nut (blue & ora
Resumen del contenido incluido en la página 8
NOTE Opener will not function unless Safe-T-Beam® System is installed and ForceControls are properly set. One-Piece Rail Assembly {Genie Pro only) for 10' or 12' door includes: • Special "Close" Limit Switch with longer Wires. • 96" Emergency Release Cord (yellow). • Rail Support Kit. Rail Assembly (1 piece) H Hol (Packaged separately) /_/ \ _ \ i ®
Resumen del contenido incluido en la página 9
RailStrap S/16"-18HexHeadShoulderBolts COIl CT RAIL TO I ©WEF_ @ 5/16"-18HexSerratedFlangeNuts @ A Turn Power Head upside down and place on a flat level surface. 1/4"-20 Hex 1/4"-20HexHead 1/4"-20Hex B Install Bumper (Figure 9). ShoulderBolts HeadBolts RailClamps SerratedFlangeNuts C Install Coupler on Motor Shaft (Figure 9). (yellow) % CAUTION @ @ @ @ Coupler Bumper Collars+ spare Retaining Clips + spare The Drive Screw and Rail Liner can slide out of Rail Sections. Keep Rail Sections level unt
Resumen del contenido incluido en la página 10
Magnetic Carriage Release Assembly _ Position kCC/ A Place Magnetic Carriage Assembly Lever in "release" position. Engaged Position (i_.... -__/_/ B Slide Magnetic Carriage Assembly into slot on End Rail To.o= Section with arrow pointing away from the Power Head (Figure 12). .................................. _ andheader Toward Power Head End Rail Section Figure 12 Slide Magnetic Carriage onto Rail A]_]'ACH RAIL STRAR TO DU© Rail Strap _@ RAIL :_E_._ [l,N A Attach Rail Strap to End Rail Section
Resumen del contenido incluido en la página 11
NOTE Antenna o Loosen (Do Not Remove) Terminal Block Screws_ o Limit Switch adjustments and securing the Wires will be done later. F Lay Wires in channel on top of Rail and secure with Wire Clips (Figure 14). G Coil and bundle excess Limit Switch Wires on top of Power Head with Twist Ties. Leave just enough Wire to reach Terminals on back of Power Head (Figure 14). H Turn Opener upside down, and connect Limit Switch Wires to Power Head Terminal Block (Figure lS): Terminal White Limit Brown Limit
Resumen del contenido incluido en la página 12
Use of Header Bracket Mount directly into header support board Center Line of door NOTE I _--____ .___ ', For lightweight garage doors, make sure you have installed 7::?: : ..... the proper reinforcement (SeeCheck Door Condition and Thickness on page 3). Bottom of bracket flange Alternative Header Bracket orientations CAUTION o The Header Bracket must be fastened to the garage framing. Do Not fasten the Header Bracket to drywall, particle board, plaster, or other such material. \ • It may be nec
Resumen del contenido incluido en la página 13
I® CAUTION Doors made of masonite, lightweight wood, fiberglass, metal, or other lightweight materials must be properly braced SECTIONAL DOORS ONE-PIECE DOORS before mounting door Opener. Center Line of door Center Line of door _o_ _'e<:tier_al doo_'_x i I A Place Door Bracket on door center line, no lower than top roller, and mark holes (Figure 19). B Attach Door Bracket: • For metal doors, use 3 (1/4" -20 x 3/4") Self-Drilling Screws (provided). Optional Door Operator Bracket (not included) •
Resumen del contenido incluido en la página 14
SECTIONAL DOORS Rail Should be level or dip down slightly. A Raise andsupport Opener Power Head (along doorcenter Check for clearance. line)higher thanhighest pointofdoortravel (using step ladder, etc.) (Figure 21). B Measure distance from Opener to garage ceiling. CAUTION H Mounting Brackets must be fastened to garage framing. Do Not fasten to drywall, particle board, plaster, or other such materials. NOTE ONE-PIECE DOORS • Make sure the rail of your supported Power Head is Set clearance at 1"-
Resumen del contenido incluido en la página 15
Clevis Pins Cotter Pins I:o_ _'sectio_al doo_'s: A Attach Curved Door Arm to Door Bracket with Clevis Pin and Safe-T-Beam ® (STB) Brackets Cotter Pin (Figure 23). B Attach Straight Door Arm to Magnetic Carriage Assembly. 3/8" x 7/8" C Attach both Arms together with 2 (3/8" x 7/8") Hex Head Hex Head Bolts Bolts and 2 (3/8") Serrated Flange Hex Serial Number Nuts so overall length is as short as pos- sible. Securely tighten fasteners. #10-16 x 11/4'. D Adjust height of Emergency Release Cord Knob
Resumen del contenido incluido en la página 16
Safe-T-Beam ® Sensor (Green LED) ELECTRICALWARNING Ensure there is No power to the Opener before installing Safe-T-Beam® System Wires. If Opener is plugged into outlet, Safe-T-Beam ® Source Unplug it now. (Red LED) NOTE Slide onto tongue of Bracket until._. J i:_1 it clicks into 4_// of Top The Opener will not close the door automatically unless the place !/i}i _. Bracket 6" Safe-T-Beam® System is installed. I above [floor A Install Safe-T-Beam ® Source and Sensor (Figure 25): • Mark both sides
Resumen del contenido incluido en la página 17
CAUTION ;taples which are too tight may cut or pinch Wires. Cut or )inched Wires can cause the Safe-T-Beam® System to stop working. When installing the Insulated Staples, make sure _oufasten them only as tightly as needed to hold the ® © Wire securely. #6-11/4" Insulated Staples Pan Head Screws (approximately 30 parts) Hardware (red bag) C Install Safe-T-Beam ®Wiring (Figure 28): • Route Wire and Insulated Staples (Figure 29 and Figure 30). - Securely fasten Wires with Insulated Staples as you g
Resumen del contenido incluido en la página 18
WF_LL C©BSS©L Security Vacation Lock Switch 1 WARNING Verify there is no power to the Opener before installing Wall [ I Independent Garage Door Console Wires. Light Control J Control NOTE More than one lighted Wall Control per Opener will cause © a malfunction. Wall Console A Wall Console (Figure 31): @ • Has a Security Vacation Lock Switch which disables all controls. Figure 31 Wall Console • LED Indicator shows whether system is powered, locked, or unlocked. Makes Console easy to find in dark.
Resumen del contenido incluido en la página 19
Co_s_scs__sG_ovv_ ELECTRICALWARNING e To reduce the risk of electrical shock, this equipment has a grounding type Plug that has a third (grounding) Pin. This Plug will only fit into a grounding type outlet. If the Plug does not fit into the outlet, contact a qualified electrician to install the proper outlet. Do Not change the Plug in any way.The door Opener must be properly grounded to prevent personal injury and damage to the components. The electrical power to the door Opener Must Be removed
Resumen del contenido incluido en la página 20
NOTE o Little effort is required to turn the Force 5elX@_{_ of Limt 5w t@_®s Adjusting Knobs. A Setting Close Limit Switch (Figure 34): • If the door stops moving while opening or closing, adjust the Open Force or Close Force • Check that Magnetic Carriage Assembly is disengaged. Controls slightly clockwise (to slightly • With garage door fully closed, slide Close Limit Switch increase the force) and retry the step. until it is aligned with Carriage Assembly Magnet. • The Open Force and Close Fo