Resumen del contenido incluido en la página 1
AL WA Y S AT YOUR COMMAND
® ™
CHAINLIFT /BELTLIFT
Models 1022/1024/1042
GARAGE DOOR OPENERS
®
Includes INTELLICODE Remote Control
Installer:
®
Safe-T-Beam System must be installed to close door.
Leave this manual
with homeowner.
For use only with sectional doors. Your Residential
Opener comes with a Rail Assembly which is standard
for up to a 7 foot high door.
® ®
Homelink and Car2U compatible
For Answers and Assistance:
®
Homelink is a registered trademark of
Johnson Con
Resumen del contenido incluido en la página 2
SAFETY INFORMATION OVERVIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMATION Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on the owner or user of this system to read, understand and implement the information in this manual. If you have questions or do NOT ® understand the information presented, conta
Resumen del contenido incluido en la página 3
TABLE OF CONTENTS OPENER FEATURES ® SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGE INTELLICODE Rolling Code Security System. An electronic rolling code system that enhances the security of SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 the door opener by continuously changing the access code each time the remote control is used. The door opener OPENER FEATURES. . . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 4
FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM PRE-INSTALLATION CHECK LIST Things to consider if you are planning to "Do-it-yourself." This opener is designed for use with SECTIONAL doors only. In many cases you will be replacing an existing door opener with a new one, however, if this will be the first opener installed there are some pre-installation issues which need to be addressed. They are as follows: The Genie Company recommends that you read and fully understand all information and in
Resumen del contenido incluido en la página 5
TYPICAL SECTIONAL DOOR INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM Pg. 19 Pg. 13 5 1 Pg. 12-13 2 TYPICAL SUPPORT ADDED BRACKET HEADER BRACKET (NOT PROVIDED) MOUNTING BOARD BRACES POWER CORD (APPROX. 45 IN.) TO 120V GROUNDED OUTLET EXTENSION SPRING OR TORSION SPRING Pg. 14 4 NOTE: This opener is designed for Pg. 17-18 use with SECTIONAL doors only. Pg. 17-18 6 3 3 Pg. 11 ® SAFE-T-BEAM SENSORS MAX. 6" MIN. 5" 7 Pg. 12 SECTIONAL DOOR WARNING To reduce the risk of injury to persons
Resumen del contenido incluido en la página 6
©Overhead Door Corporation 06/2007 RECOMMENDED TOOLS FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM Pencil 3/16" Drill Bit Carpenter’s level Drill Wire strippers Adjustable wrench Ratchet Tape measure Safety Glasses Step ladder Hammer 1/4", 7/16", 3/8" and Phillips screwdriver 1/2" Sockets PARTS IDENTIFICATION - Not Shown Full Size . ARRANGING BOX CONTENTS FOR ASSEMBLY ORGANISATION DU CONTENU DE LA BOÎTE POUR LE MONTAGE DISPOSICIÓN DEL CONTENIDO DE LA BOLSA PARA EL MONTAJE Remove internal boxe
Resumen del contenido incluido en la página 7
Shown Full size ( FASTENERS - See Parts List below for full description.) BAG NO. DESCRIPTION QUANTITY 0 RAIL SECTION CLAMP 2 RAIL CLAMP BOLT – 5/16''-18 x 5/8'' 8 HEX FLANGE NUT – 5/16''-18 8 1 BOLT – 5/16''-18 x 1/2'' 3 Rail Clamp Bolt - 5/16"-18 x 5/8" 2 CLEVIS PIN, LONG – 5/16" x 3" 1 COTTER PIN 1 HEADER BRACKET 1 LAG SCREW – 5/16'' x 2'' 2 3 HEX BOLT – 5/16''-18 x 3/4'' 5 #10-16 x 1-1/4" Phillips Hex Screw HEX FLANGE NUT – 5/16''-18 5 LAG SCREW – 5/16'' x 2'' 2 4 SELF DRILLING SCREW – 1/4''
Resumen del contenido incluido en la página 8
FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 1-PIECE RAIL HARDWARE ASSEMBLED VIEW Power Cord Rail with chain Power Head Trolley Slide CHAIN Release Knob Tensioner Chain Clevis Pin, Long BELT Header & Cotter Pin Bracket 3-PIECE RAIL HARDWARE ASSEMBLED VIEW Power Cord Rail with chain Rail Clamps Power Head Trolley Slide Rail Clamp Bolts Release CHAIN Knob Rail with belt End Rail Rail Clamp Nuts Center Rail Tensioner Chain Release Knob End Rail Clevis Pin, Long BELT Header & Cotter Pin Cen
Resumen del contenido incluido en la página 9
IMPORTANT INSTALLATION INSTRUCTIONS WARNING: To reduce the risk of severe injury or death: 1. READ AND FOLLOW ALL SAFETY, INSTALL ATION 5. Do NOT connect the opener to source of power AND OPERATION INSTRUCTIONS. (If you have until instructed to do so. questions or do not understand an instruction, call The 6. Locate the control button: ® Genie Company or an authorized Genie Dealer.) • Within sight of door, 2. Install only on a properly balanced sectional garage door. • At minimum height of 5
Resumen del contenido incluido en la página 10
Rail Assembly for CHAIN DRIVE OPENER CHAIN DRIVE RAILS NOTE: For split rail clamps, nuts, and bolts locate Bag 0 from Box 1. Chain Rail Center Rail A 3. Remove the two rail sections that are not connected to the chain and place them on floor (Fig. 1-2, A). End Rail 4. Carefully remove the third rail section with chain and plastic sleeve. Place rail section on floor and extend chain straight out Wire Tie(s) B (Fig. 1-2, B). Chain and rail should extend approximately 7 feet. 5. Remove wire ties
Resumen del contenido incluido en la página 11
POWER HEAD & RAIL ASSEMBLY Use 5/16"-18 x 1/2" Assembly for CHAIN DRIVE OPENER Bolts NOTE: Handle carefully! Drive chain can slide out of rail. NOTE: For power head and rail assembly locate Bag 1 from Box 1. 1. Attach rail assembly to power head by aligning the sprocket onto the motor shaft. Use (3) FIG. 1-5 Rail - Power head assembly. bolts, 5/16"-18 x 1/2" (Fig. 1-5). 2. Tighten the chain by turning the adjustment Chain Pulley Bracket (at wall end of rail) nut clockwise. The chain adjustment
Resumen del contenido incluido en la página 12
final height mark door at highest point final height mark 2-1/2" door at highest point INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 2 b) - extend HEADER AND DOOR vertical line MOUNTING BRACKETS: 2-1/2" WARNING Header bracket must be fastened to garage d) - final c) - door at framing. Do NOT fasten to drywall, particle height mark board, plaster or other such materials. highest point 1. Finding header bracket mounting location. • Close garage door. – Use a pencil and level.
Resumen del contenido incluido en la página 13
NO HEADER BRACKET MOUNTING THE OPENER: 1. Getting started. • Position assembled rail on wall next to header bracket (Fig. 2-4). – Place material on floor under power head to protect from scratching. (A box, stool, or VIEW similar device may be needed to clear a FROM ABOVE (not to scale) torsion spring.) NOTE: For header bracket pins locate Bag 2 from Box 1. 2. Mounting the assembly. YES / SÍ / OUI • Attach rail to header bracket using clevis pin and cotter pin. FIG. 2-4 Position assembly
Resumen del contenido incluido en la página 14
DOOR BRACKET: CAUTION Doors made of masonite, lightweight wood, centerline fiberglass, and sheet metal must be properly braced before mounting door opener. Contact door manufacturer or distributor for a bracing kit. centerline The Genie Company is not responsible for even with or damage caused due to improperly braced door. above top roller NOTE: For door bracket and bolts locate Bag 4 FIG. 2-7 Mounting door Bracket. from Box 2. 1. Finding door bracket mounting location. • Door bracket is mo
Resumen del contenido incluido en la página 15
B W WALL BUTTON INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 3 Wire from WARNING power head to wall control. Verify there is NO power to the opener before installing Wall Button wires and Wall Button. CAUTION Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the Wall button to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly. Wall control WARNING "Entrapment" Use of any
Resumen del contenido incluido en la página 16
Locking 3.Securely fasten wires. Clips Terminal • Securely fasten wires to ceiling and Holes wall using insulated staples provided. – Use insulated staples. 6 5 4 3 2 1 – Staples should be snug only. Insulated Staple • If rear cover is attached to power head, remove it. • On power head: – Route Wall Button wires through wire guide. 6 5 4 3 2 1 – Split and strip ends of wire (Fig. 3-2 on +– previous page). PB – Insert wire into terminal holes and lightly press in Infared Sensor the orange l
Resumen del contenido incluido en la página 17
® SAFE-T-BEAM SYSTEM INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 4 WARNING There should be no electrical power to the opener ® while installing Safe-T-Beam wires. If you have plugged in the power cord—UNPLUG IT NOW! NOTE: The opener will not close the door ® automatically unless the Safe-T-Beam System is installed. mark NOTE: For Sensors, screws, wire, and insulated staples locate items and Bag 8 from Box 3. FIG. 4-1 Mark door frame. 1. Mounting brackets. • Mark both sides o
Resumen del contenido incluido en la página 18
3b. Wiring (pre-wired). ® • Route wire from wall to Safe-T-Beam sensors Wall Wall (Fig. 4-5b). Red Green • Splice pre-wiring to shortened sensor wire, Source Sensor match wire pairs dash-to-dash and plain-to-plain. - Trim sensor wire to approximately one foot (1 ft) from sensor. - Split and strip ends of sensor wires and Ceiling 6 5 4 3 2 1 or 6 5 4 3 2 1 pre-wired wires (Fig. 4-7). - Splice wires together with (provided) Power Dashed Line = striped wire Head Solid
Resumen del contenido incluido en la página 19
CONNECTING TO POWER FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 5 WARNING • To reduce the risk of electrical shock, this equipment FIG. 5-1 Connect to power. has a grounded type plug that includes a third (grounding) pin. This plug will only fit a grounded type outlet. If you do not have a grounded outlet, contact Motor Cover Screws a qualified licensed electrician to install one. DO NOT alter the plug in any way. The door opener must be properly grounded in order to prevent personal inju
Resumen del contenido incluido en la página 20
Move in this direction Move in this direction DOOR LIMITS FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 6 WARNING • Severe injury or death can result if the door Limit Controls location closing force is set too high. on power head. • Never increase the door closing force above the minimum required to move the door. • Never adjust force to compensate for a sticking or binding door. • Perform monthly CONTACT REVERSE TEST as described on page 22 and in Section 10. Open LED Open Indicator