Resumen del contenido incluido en la página 1
Owner’s Manual
MG2000 J1939
Tachometer
IS0224
rev. A ecr#6115 04/2006
Resumen del contenido incluido en la página 2
Index Description Normal Mode page 4 Contrast and Lighting page 4 Troll Control page 5 Displayed Functions page 5 Default screen 1 page 5 Default screen 2 page 5 Default screen 3 page 5 Default screen 4 page 6 Default screen 5 page 6 Default screen 6 page 6 Default screen 7 (Alarms) page 6 Figure 2 - Select Mode page 7 Figure 3 - LCD Display Screens page 8 Edit Mode page 9 Functions that are adjusted in Edit Mode. page 9 Instructions Select Default Screen page 10 Reset
Resumen del contenido incluido en la página 3
Engine Emergency Stop page 22 Low Oil Pressure page 23 High System Voltage page 23 Low Oil Pressure page 23 Low System Voltage page 23 Low Coolant Level page 23 Water in Fuel page 23 High Boost Pressure page 24 Rev Limit Exceeded page 24 Engine Emergency Stop page 24 High Engine Temp page 24 Table - J1939 MG2000 Tachometer PGN’s Supported page 26 Harness HN0587 - Tachometer/Speedometer Cable page 27 Harness HN0401 - NMEA 0183 Cable page 29 Harness - Wate
Resumen del contenido incluido en la página 4
This page left blank intentionally.
Resumen del contenido incluido en la página 5
® turned off. The unit will power up first Faria MG2000 J1939 showing the Self Test screen and then Tachometer Manual the default screen set at the factory or The Faria MG2000 Tachometer the screen selected by the user in the combines the features of an ECU serial Default Screen Edit selection prior to bus gateway and several instruments shut off. into one unit: Normal Mode default screens for • The tachometer is analog in MG2000 J1939 tachometer appearance but is driven by a ste
Resumen del contenido incluido en la página 6
3650 RPM Oil Pressure Trim Sync 20.1 PSI The instrument has three push buttons; Fuel Left “M” (MODE), “Down”, and “Up”; that 3650 RPM On Off control the functions available. The “M” 50.0 GAL (MODE) button is used to change the Oil Pressure Fuel Used Trim Sync function of the LCD display and to access 20.1 PSI 17.5 GAL 41˚21N 072˚06W submenus and adjustable settings. The Fuel Inst “Down” and “Up” buttons are used to modify the settings. 5.5 GPH P S Trans Gear 3650 RPM
Resumen del contenido incluido en la página 7
appear. The information below applies to the MG2000 as received with no user changes to the screen selections. Contrast and Lighting In the “Normal” operating mode When the “Edit” menus have been the instrument display contrast and selected, press the “Mode” button to display mode can be adjusted by return to “Normal” mode. pressing the “Down” and “Up” buttons. Press the “Down” or “Up” buttons to cycle With the display in “positive” mode, black between the available “Edit” function
Resumen del contenido incluido en la página 8
Displayed Functions Fuel Level Tachometer Displays the current amount of fuel The tachometer is a digital instrument remaining in the tank as received by the with the appearance of an analog tachometer fuel sender input. 3650 RPM instrument. The tachometer receives 3650 RPM data directly from the ECU so no settings Water Press Oil Pressure Trim Sync are normally required. The setting for Analog input. Displays engine water Oil Pressure Trim Sync 20.1 PSI the tachometer dial range is set at
Resumen del contenido incluido en la página 9
3650 RPM Oil Pressure Trim Sync 20.1 PSI 3650 RPM Oil Pressure Trim Sync 20.1 PSI Engine Load Trans Gear Displays the current percent load on On Off the engine as received from the engine 2 Forward ECU. Trans Temp 41˚21N 072˚06W VOLTS 330˚ F On Off Trans Press 13.8 Volts 200 PSI Water Press P S 41˚21N 072˚06W 20 PSI Coolant Tmp Screen “4” Trans Gear 215 ˚F P S Displays the current gear as received Screen “6” from the transmission ECU. Example Volts Displ
Resumen del contenido incluido en la página 10
information to be displayed about the LCD Display Screens: alarm, also if more than one alarm is Below is flow diagram of how to maneuver occurring scrolling is possible in the between screens and modes. In the “VIEW” mode by using the “Up” or “Normal” mode, press “Mode” once to “Down” buttons. enter screen “Select” mode, press “Up” or “Down” to move between screens. Internal alarm values can be set for “Low Screen “1” Fuel”. Default Screen “2” Screen “3” Screen “4” Screen “5” Screen
Resumen del contenido incluido en la página 11
1. Select Default Screen 2. Reset Fuel Used 3. Set Fuel Tank Full 4. Set Amount of Full 5. Organize User Screens 6. Select Gauge Range 7. Select Fuel Sender 8. Select Display Units 9. Select Fuel Tank Size 10. Fuel Tank Calibrate 11. Low Fuel Alarm 12. Select Self Test 13. Software ID & Revision Page 8
Resumen del contenido incluido en la página 12
“Edit” Mode Screens for Edit Mode MG2000 J1939 Tachometer The “Edit” mode is used to adjust or set the values of numerous functions and Enter the “Edit” mode from “Normal” options in the MG2000. The procedure mode by pressing and holding the “Mode” below specifies the steps to be taken in button and the “Up” button for approx. the “Edit” mode to adjust / set each option. 2 seconds The first editable screen To enter “Edit” mode, press the “Mode” will appear. By repeatedly pushing and a
Resumen del contenido incluido en la página 13
Instructions – Function Line Display 1 Select Select Default Screen 2 Default Screen 3 Press and hold the “Up” and “Down” buttons for 2 seconds to enter the “Select Default Screen” function. Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. 1 Default 2 Display (Display Screen 1 is the “Default” at first turn on) 3 Screen: 1 4 Press and hold the “Up” and “Down” buttons for 2 seconds to select screen 1 as the “Default Screen” and exit back to “Edit” mode. Pre
Resumen del contenido incluido en la página 14
1 Set Set Fuel Tank Full 2 Fuel Tank Full 3 NOTE: In order to use the “Fuel Left” function, the owner must set this function when the fuel tank is filled or use the set amount of fuel below. In addition, if the “Set Fuel Tank Full” function is used, the “Fuel Tank Size” must be set correctly to the size of the fuel tank in this application. The computer will monitor fuel usage and calculate the fuel left in the tank. This function does not replace the fuel level function provided by the
Resumen del contenido incluido en la página 15
Press and hold the “Up” and “Down” buttons for 2 seconds to enter the “Organize User Screens” function. Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. Organize screen 1 1 Set up 2 Screen Refer to the list of available functions later in this 1 3 manual. Press and hold the “Up” and “Down” buttons for 2 seconds to select “Set up Screen 1”. Press “Up” or “Down” to select another screen to organize or “Mode” to return to “Edit” mode. 1 Screen 1 Press “Up”
Resumen del contenido incluido en la página 16
1 Set up 2 Screen 1 3 Repeat for remaining screens (2, 3, 4, 5, & 6 ). Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. 1 Select Select Gauge Range 2 Gauge Range 3 Press and hold the “Up” and “Down” buttons for 2 seconds to enter the “Select Gauge Range” function. Press “Up” or “Down” to select another function. 1 Select Select Oil Pressure Dial 2 Oil Pressure Dial 3 Press and hold the “Up” and “Down” buttons for 2 seconds to select the “Oil Pressure Dial
Resumen del contenido incluido en la página 17
1 Select Press “Up” or “Down” to scroll through the selections. 2 Coolant Temp 3 Dial When the correct choice is next to the selection arrow, 4 60-220 F Press and hold the “Up” and “Down” buttons for 2 seconds 5 > 100-250 F to save the selection and return to select another Dial. 145-240 F 6 1 Select Select Voltmeter Dial 2 Voltmeter Dial 3 Press and hold the “Up” and “Down” buttons for 2 seconds to select the “Voltmeter Dial”. Press “Up” or “Down” to select another Dial
Resumen del contenido incluido en la página 18
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Boost Pressure Dial”. Press “Up” or “Down” to select another Dial. Press “Mode” to return to “Edit” mode. 1 Select Press “Up” or “Down” to scroll through the selections. 2 Boost Press 3 Dial When the correct choice is next to the selection arrow, 4 0-70 PSI Press and hold the “Up” and “Down” buttons for 2 seconds > 0-30 PSI 5 to save the selection and return to select another Dial. 0-50 PSI 6 1 Select Sel
Resumen del contenido incluido en la página 19
Press and hold the “Up” and “Down” buttons for 2 seconds to select the “Pressure Units”. Press “Up” or “Down” to select another choice of “Units” 1 Press “Up” or “Down” to scroll through the selections. Select 2 Pressure When the correct choice is next to the selection arrow, 3 Units Press and hold the “Up” and “Down” buttons for 2 seconds 4 BAR to save the selection and return to select another choice of 5 “Units”. > PSI 1 Select Select Volume Units 2 Volume Units 3 Press and hold
Resumen del contenido incluido en la página 20
Press and hold the “Up” and “Down” buttons for 2 seconds to enter the “Select Fuel Tank Size” function. Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. 1 Select 2 Standard Press and hold the “Up” and “Down” buttons for 2 seconds to select “Standard Fuel Tank Size”. Fuel Tank 3 Size 4 Review the list of standard fuel tank sizes for a size that 1 Select matches the fuel tank in the application. 2 Fuel Tank Press “Up” or “Down” to scroll through the selectio