Resumen del contenido incluido en la página 1
PRINTERS INSTRUCTIONS:
INSTR,INSTL,AK-11,ACCESS - LINEAR P/N: 227975 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH
AK-11
Digital Keyless Entry System
Installation and Programming Instructions
(760) 438-7000
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
Resumen del contenido incluido en la página 2
CONTENTS SPECIFICATIONS MECHANICAL INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Case dimensions: 4.00" W x 5.50" H x 3.00" D FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ELECTRICAL COMPONENT LOCATIONS . . . . . . . . . . . . . . . . . . . . . . 3 Voltage: 12-24 Volts AC or DC WIR
Resumen del contenido incluido en la página 3
COMPONENT LOCATIONS RED/GREEN YELLOW POWER/ACCESS "LOCKOUT" INDICATOR INDICATOR JUMPER JP2 RESETS MASTER CODE TERMINAL NIGHT BLOCK J3 LIGHT OUTPUTS JUMPER JP1 REMOVE TO TACTILE REDUCE TERMINAL BLOCK J4 KEYPAD BEEPER SOUND POWER AND INPUTS KEYLOCK Figure 1. Component Locations WIRING DIAGRAM TYPICAL GATE INSTALLATION WIRING TYPICAL DOOR INSTALLATION WIRING AK-11 AK-11 J3 J3 N.O. 1 N.O. 1 COMMON COMMON RELAY #1 2 RELAY #1 2 TO ALARM N.C. 3 N.C. 3 SYSTEM J4 J4 OUTPUT #3 OUTPUT #3 4 4 1 1 OUTPUT #4
Resumen del contenido incluido en la página 4
INSTALLATION To avoid damage to the unit from static discharges, connect the EARTH GROUND terminal to a good earth grounding point. Suggested wiring size is 18 AWG for earth ground and power (up to 500 feet of 18 AWG wire can be run for power, use larger wire for longer runs). Use 22 AWG or larger (depending on the load) PEDESTAL for all other connections. CAUTION: If the unit is AC powered, and one side of the power transformer secondary is connected to earth ground, connect the grounded sid
Resumen del contenido incluido en la página 5
Gate Control Door Control Route four wires between the gate and the keypad (two for Install a low voltage electric door strike for unlocking the power, two for control). door. Connect the gate operator’s auxiliary or radio power output Choose a location for the power supply or transformer. terminals to the keypads POWER input terminals (observe Route two wires between the power supply and the wiring polarity). keypad. Connect the power supply’s output terminals to Connect the gate operator’s OPE
Resumen del contenido incluido en la página 6
Setting Entry Code Length Default: 4 digits FACTORY DEFAULTS MASTER PROGRAMMING CODE . . . . . . . . . . . . . . . . . . . . 123456 Press: 0 3 Length # # ENTRY CODE LENGTH . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DIGITS Length = 1 - 6 for entry code length REQUEST-TO-ENTER OUTPUT . . . . . . . . . . . . . . . . . . RELAY #1 NOTE: If the Entry Code Length is going to be changed from ALARM SHUNT OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . DISABLED the factory default of
Resumen del contenido incluido en la página 7
Select Alarm Shunt Output Default: No Output PROGRAMMING OPTIONS Sets which output activates during the time access is granted. (Use this output to shunt alarm contacts attached to the access door.) This output may be timed or latched. Select Door Sense or Inhibit Input Default: Door Sense Press: 1 5 Output # # The input on terminal block J4, terminal #3 can be programmed Output = Output to Activate (0-4) for DOOR SENSE or INHIBIT. 1 = Relay #1 2 = Relay #2 3 = Output #3, 4 = Output #4
Resumen del contenido incluido en la página 8
Beep Sounds on Keystrokes Default: Yes Master Reset Selects whether or not the keypad beeps as each key is pressed. CAUTION: Performing a master reset will clear the entire memory of the AK-11 and return all programmable options to the factory default values. ALL ENTRY CODES WILL BE Press: 4 0 Sound # # ERASED. Sound = 1 for Yes = 0 for No STEP 1 Disconnect power from the keypad. STEP 2 Press and hold down the and keys. # Beep Sounds During Relay #1 Default: No * STEP 3 Apply power to th
Resumen del contenido incluido en la página 9
Solid State Outputs Locking Keypad The two solid state outputs (Output #3 & Output #4) can be After the installation is complete. Lock the keypad using the programmed to activate during various conditions. These keylock (see Figure 9). outputs can be used to activate indicators or sounders. See Figure 7 for wiring examples using the solid state outputs. DC POWER SOURCE ELECTRONIC BEEPER 1K Ω @ 12 volts 2K Ω @ 24 volts LED LED EACH OUTPUT #3 OUTPUT OUTPUT #4 100 mA MAXIMUM EXAMPLE 1: OUTPUT #3 L
Resumen del contenido incluido en la página 10
AK-11 OPERATION Users of the AK-11 have up to 40 seconds to key in their entry code. Up to eight seconds are allowed between each keystroke. All digits of the entry code must be entered. Example: If the code is 0042, the user must enter “0 0 4 2”. If the wrong key is pressed, pressing the key will * reset the keypad. The correct code can then be re-entered. After a correct code is entered, the red LED will turn green and the programmed relay will activate for the programmed time. I
Resumen del contenido incluido en la página 11
MANAGER’S ENTRY CODE LOG NAME ADDRESS OR APARTMENT NUMBER ENTRY CODE RELAY NUMBER ◊ 1 Timed ◊ 2 Timed ◊ 1 Toggled ◊ 2 Toggled ◊ 1 Timed ◊ 2 Timed ◊ 1 Toggled ◊ 2 Toggled ◊ 1 Timed ◊ 2 Timed ◊ 1 Toggled ◊ 2 Toggled ◊ 1 Timed ◊ 2 Timed ◊ 1 Toggled ◊ 2 Toggled ◊ 1 Timed ◊ 2 Timed ◊ 1 Toggled ◊ 2 Toggled ◊ 1 Timed ◊ 2 Timed ◊ 1 Toggled ◊ 2 Toggled ◊ 1 Timed ◊ 2 Timed ◊ 1 Toggled ◊ 2 Toggled ◊ 1 Timed ◊ 2 Timed ◊ 1 Toggled ◊ 2 Toggled ◊ 1 Timed ◊ 2 Timed ◊ 1 Toggled ◊ 2 Togg
Resumen del contenido incluido en la página 12
LINEAR LIMITED WARRANTY FCC NOTICE This Linear product is warranted against defects in material and Changes or modifications not expressly described in this manual workmanship for twenty-four (24) months. The Warranty or approved by the manufacturer could void the user’s authority Expiration Date is labeled on the product. This warranty to operate the equipment. extends only to wholesale customers who buy direct from This equipment has been tested and found to comply with the Linear or through L