Resumen del contenido incluido en la página 1
1
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
THIS FIREPLACE HAS BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CAN/ULC S610, UL 127, FOR ZERO CLEARANCE FIREPLACES, AND TO ULC
S639 FOR STEEL LINER ASSEMBLIES FOR SOLID FUEL BURNING MASONRY FIREPLACES. CERTIFIED UNDER USA ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND
THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q
Resumen del contenido incluido en la página 2
2 INTRODUCTION WARNINGS AND SAFETY PRECAUTIONS ! W415-0676 / 03.14.08 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454
Resumen del contenido incluido en la página 3
3 TABLE of CONTENTS PG 2-6 INTRODUCTION 16 OPTIONAL BLOWER Warnings and Safety Precautions 16 FEATURES Specifi cations Controlling Combustion Air Warranty Achieving Proper Draft Installation Overview General Instructions 17-18 OPERATING INSTRUCTIONS General Information Fuel Loading and Burn Cycle Care of Glass and Plated Parts Ash Removal Procedures 7 HI-EFFICIENCY HEATING 18 MAINTENANCE Five Options Gasket / Baffl e Replacement Door Glass Replacement
Resumen del contenido incluido en la página 4
4 NAPOLEON® products are manufactured under the strict Standard of the World Recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON®. NAPOLEON® WOOD FIREPLACE PRESIDENT'S L
Resumen del contenido incluido en la página 5
5 INSTALLATION OVERVIEW FIGURE 2 ! WARNING This fi replace and its components are designed to be installed and operated as a system. Any alteration to or substitution for items in this system, unless allowed by these installation instructions, will void the Warnock Hersey, listing and may void the product war- ranty. It may also create a hazardous installation. Read through these instructions thoroughly before starting your installation and follow them carefully throughout your project. W415
Resumen del contenido incluido en la página 6
6 Your fi replace must be installed in accordance with all national and local GENERAL INSTRUCTIONS building code standards and the standard of Chimney and Fireplaces, Vents and Solid Fuel Burning Appliances NFPA #211. Consult the This is the most effi cient, authority having jurisdiction (such as municipal building department, simple and trouble free fi re department, fi re prevention bureau, etc.) to determine the need woodburning system to obtain a permit. If you are in doubt about the pro
Resumen del contenido incluido en la página 7
7 HI-EFFICIENCY HEATING FIVE OPTIONS ATTIC To operate this hi-effi ciency fi replace as a basic system, the blower is not required, however, to enhance its effi ciency a blower is rec- ommended. OPTION FOR A BLOWER KIT (NZ62) This blower is installed in the bottom of the unit BLOWER TYING LOCATION INTO and used to direct the heat into the room where the fi replace is lo- OPTIONS EXISTING DUCT cated. The blower is controlled, by a variable speed switch, located WORK inside the fi replace. A THE
Resumen del contenido incluido en la página 8
8 INSTALLATION / FRAMING ! WARNING Before starting, do the following: 1. For protection wear gloves and safety glasses. 2. Keep hand tools in good condition, sharpen cutting edges and make sure tool handles are secure. 3. Always maintain the minimum air space required to the enclosure to prevent fi res. MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: ! WARNING Fireplace framing: Top Stand-Off 0" Carefully follow the instructions for assembly of the chimney and ot
Resumen del contenido incluido en la página 9
9 The fi replace should be framed using 2x4 lumber. For the header and cripple studs above the fi replace it is recommended to use steel. The fi replace must be secured to the fl oor in all cases. Use the pallet packing brackets to secure to the fl oor. If ducting is to be installed, the minimum enclosure ceiling height is 84". Without ducting, the ceiling height may be brought down to a minimum of 72". However a fi replace enclosure with a height less than 84" must be provided with suffi cient air
Resumen del contenido incluido en la página 10
10 W415-0676 / 03.14.08 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454 ENCLOSURE FINISHING ENCLOSURE ALTERNATE FINISHING FIGURE 8b FIGURE 8a 12” MAXIMUM 1” OPEN 72” MINIMUM ENCLOSURE HEIGHT 72” MINIMUM VENTILATION ENCLOSURE HEIGHT REQUIRED IN ENCLOSURES BETWEEN 72” VENTILATION REQUIRED IN AND 84” ENCLOSURES BETWEEN 72” AND 84” 12” MAXIMUM Minimum 40 square inches of ventilation opening required, bothat the top and bottom of the
Resumen del contenido incluido en la página 11
11 OUTSIDE COMBUSTION AIR MANTEL CLEARANCES Model NZ-26 has the option of taking outside air directly into the Mantel clearance can fi replace through the opening on the left hand side or taking inside vary according to the air through the lower front louvres or a combination of both. mantel depth. If the optional fresh air kit (available through your authorized dealer) is installed, it must not draw air from the attic or garage. It may only come from outside the house. The maximum length of
Resumen del contenido incluido en la página 12
12 FIGURE 11 - STRAIGHT UP FIGURE 12 - 2 ELBOWS FIGURE 13 - 4 ELBOWS No Off-Set. Minimum overall chimney height Single off-set with two 15°, 30° or 45° Double off-set with four 15°, 30° or 45° elbows. Minimum overall chimney height elbows. Minimum overall chimney height is 11 feet. is 11 feet. is 11 feet. * The fi rst fl ue offset closest to the top of the unit must be a NOTE: 30° or 45° offsets may be installed back to back. minimum distance of 12" from the top of the fi replace. ADDING CHIMNEY
Resumen del contenido incluido en la página 13
13 IF THE CHIMNEY IS UNLINED: FIGURE 17 A stainless steel liner listed to either Standard ULC- S640M, ULC-S639 in Canada or UL-1777 in the USA: Liners for New Masonry Chimneys, may be used to connect the fireplace to the chimney. The liner INSTALLING FLASHING AND must be continuous from the fireplace STORM COLLAR to the chimney cap Remove the nails from the shingles above and to the sides of the and be installed only chimney. Place the fl ashing over the chimney pipe and slide un
Resumen del contenido incluido en la página 14
14 FINAL ASSEMBLY ATTACHING THE HANDLE Attach the handle as shown so that when the door is closed, the handle will be centred in the slot located on the fi replace front. To achieve this you may T TOP OP FLAME SPREADER FLAME SPREADER have to experiment (on the upper and lower screws) with one of the variations shown. Tighten securely. BOTT BOTTOM FLAME SPREADER OM FLAME SPREADER FIBRE BAFFLE (1 OF 2 SHOWN) FIBRE BAFFLE (1 OF 2 SHOWN) T TOP OP FIREBRICK (1 OF 2 SHOWN) FIREBRICK (1 OF 2 SHOWN
Resumen del contenido incluido en la página 15
15 If you need to remove the bricks (to lighten the fi replace for ease of installation, replacement, etc), follow this sequence: For Firebrick Removal: Remove the ashwell grate. This allows 4 the four bottom bricks to be removed fi rst. Slide out the baffl e support bracket from above the front tube. Reaching above the top fi rebricks and baffl es, lift and tape the bot- tom fl ame spreader to the top spreader to ease top brick and baffl e removal and to avoid damaging the fi bre baffl e. Remove th
Resumen del contenido incluido en la página 16
16 OPTIONAL BLOWER INSTALLATION ! WARNING INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States. 1. Turn off any electrical power to the fi replace (if applicable). Open the lower louvred control door. 2. Locate the vibration reducing pad over the two threaded stud
Resumen del contenido incluido en la página 17
17 OPERATING INSTRUCTIONS Remove all source of gasoline or other fl ammable vapours and FUEL LOADING AND BURN CYCLE liquids in the vicinity of this or other appliances prior to light- ing. Ensure that the top fi rebricks and fi bre baffl es are in place For maximum effi ciency, when the fi replace is thoroughly hot, load and not lifted up. it fully to the top of the door opening and burn at a medium low set- ting. The bricks will be nearly all white and the glass mostly clear. When fi rst installed
Resumen del contenido incluido en la página 18
18 ASH REMOVAL PROCEDURES A bed of ashes approximately 1" deep should be left on the fi rebox Never operate your fi replace with the ash well in an open posi- bottom to help maintain a hot charcoal bed. When the fi re has burned tion! down and cooled, remove any excess ashes. To use your ash pan, pull This creates a fi re hazard that may result in a house/chimney fi re, the ash dump handle forward to an open position. Rake the excess internal damage to the stove or discoloration to the gold plat
Resumen del contenido incluido en la página 19
19 REPLACEMENTS Contact your dealer for questions concerning prices and avail- ability of replacement parts. Normally all parts can be ordered ! WARNING through your Authorized dealer or distributor. Failure to position the parts in accordance with these diagrams or When ordering replacement parts always give the following failure to use only parts specified approved with this appliance may information: result in property damage or personal injury. 1. MODEL & SERIAL NUMBER OF FIREPLACE 2.
Resumen del contenido incluido en la página 20
20 W415-0676 / 03.14.08 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454