Resumen del contenido incluido en la página 1
MODEL CMA-180
Installation & Operation
Rev 2.03
CMA DISHMACHINES
12700 KNOTT AVENUE
GARDEN GROVE, CALIFORNIA 92841
800-854-6417
FAX 714-895-2141
www.cmadishmachines.com
Resumen del contenido incluido en la página 2
Table of Contents CMA-180 1. SPECIFICATIONS................................................................................................. 2 1.1 CMA-180/CMA-180T.................................................................................................................... 2 1.1. CMA-180/CMA-180T.................................................................................................................... 3 2. GETTING STARTED...................................................
Resumen del contenido incluido en la página 3
1. Specifications Metric Equivalent 1.1 CMA-180/CMA-180T WATER CONSUMPTION PER RACK .96 GAL. (3.6 L) PER HOUR 52 GAL. (197 L) OPERATING CYCLE WASH TIME-SEC 49 49 RINSE TIME-SEC 12 12 TOTAL CYCLE 61 MIN. 61 MIN. OPERATING CAPACITY RACKS PER HOUR (NSF rated) 60 60 WASH TANK CAPACITY 8 GAL. (30.3 L) PUMP CAPACITY 68 GPM (257 LPM) WATER REQUIREMENTS WITHOUT BOOSTER HEATER 180°F (82°C) WITH BOOSTER HEATER 140°F (60°C) WATER INLET ¾”
Resumen del contenido incluido en la página 4
1.1. CMA-180/CMA-180T VOLTS PHASE AMPS ELECTRICAL RATING WITHOUT BOOSTER 208 1 28/35 240 1 30/38 208 3 20/24 240 3 21/26 ELECTRICAL RATING 208 1 71/78 240 1 80/88 WITH BOOSTER 208 3 45/49 240 3 50/55 SHIPPING WEIGHT 332# WITHOUT BOOSTER 375# WITH BOOSTER MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page 3
Resumen del contenido incluido en la página 5
2. Getting Started 2.1. Introduction to CMA-180 The CMA-180 is a hot water sanitizing, single rack, door-type dishmachine. It is a stand-alone machine featuring a self-contained booster heater (optional). The only external connections necessary are power supply, water supply, drainpipe, and chemical dispensers. The machine utilizes recirculated wash water and fresh water final rinse. The CMA-180 can be converted both as a straight through and corner with a door handle kit. Oper
Resumen del contenido incluido en la página 6
2.2. Receiving and Installation Step 1: Remove packaging material. Step 2: Remove service manual and machine legs from inside the wash tank. Step 3: Install legs into dishmachine leg lockets and adjust the feet. Set the machine in place. Level the machine side – to – side and front – to – back. Step 4: It is recommended that a distance of at least eight inches (8”) be between the table scrap sink and the dishmachine. * 2.2.1. Electrical
Resumen del contenido incluido en la página 7
flexibility to permit the machine to be moved for cleaning without having to disconnect any wiring. ii. Run your dispenser wires through the conduit to the control box. iii. Run your probe wires to the control box. iv. With the machine’s power “OFF”, connect your detergent and rinse dispenser wires to the red and blue terminals of the power block supplied inside the control box. The table that follows lists the function of each conductor of the multi- conductor electrical cable. Wir
Resumen del contenido incluido en la página 8
2. Remove the plug from the mixing chamber located by the vacuum breaker on the back of machine; and install the rinse injection fitting (supplied with your dispenser). 3. A 7/8” detergent injection hole is provided in the back of the wash tank. Remove the S.S. plug and install the detergent fitting (supplied with your dispenser). 4. A 7/8” chemical probe hole is provided in the front of the wash tank heater just below hi limit switch. Insert the probe into the hole from inside th
Resumen del contenido incluido en la página 9
2.2.4. Exhaust Fan Control MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page 8
Resumen del contenido incluido en la página 10
2.2.5. Water Tempering Kit MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page 9
Resumen del contenido incluido en la página 11
2.2.6. Installation Checklist Dishmachine checked for concealed damage. Hot water supply is 140° (60°C) Incoming water supply line is ¾”. Incoming water supply is 6 gpm minimum capable at 20 psi flow pressure. Machine circuit breaker is properly sized. Service voltage and phase type are correct to machine data plate. High leg of voltage is connected to L2 (three-phase). Dishmachine is properly ventilated. Floor drain plumbing is installed with air gap. Dishmac
Resumen del contenido incluido en la página 12
2.2.7. Machine Start-Up Procedures 1. Open doors and install the overflow & scrap trap on the right side of the machine. 2. Place the scrap baskets over the wash tanks. 3. Secure the wash & rinse arms and check the free-spin. 4. Open the control cover and select ‘normal” toggle switch position. 5. Adjust the rinse pressure to 20 psi flow pressure using the regulator and the gauge. a. Turn the power switch to the “Off” position. b. Close doors and open the hand-operated fill valve un
Resumen del contenido incluido en la página 13
2.2.8. Electrical Requirements The CMA-180 comes standard factory, wired for 3-phase operation. Check the electrical data plate to confirm this. If the account requires 1 phase, refer to “Electrical Requirements”, Section 1-A, for proper wiring instruction for conversion. Also check the wiring diagram to properly wire the terminal power block, tank heater, and booster heater for 1 phase (or 1B diagram below). SINGLE PHASE POWER NOTE: 80 amp service is required when CMA-180 is w
Resumen del contenido incluido en la página 14
3. Wiring Options 3-Phase and 1 Phase Wiring Options Single-Source Single-Source Single-Source Two-Source Single-Source 220V 3-Phase 220V 3-Phase 220V 1-Phase 220V 1-Phase 220V 1-Phase (20 amp/12 g*) (50 amp/8 g*) (80 amp/4 g*) (50 amp/8 g*) (30 amp/10 G*) (30 amp/10 g*) (without Booster) (without booster) *g=gauge DISPENSER HOOK-UP 1. The power signal is 208/230 volts. The power block is labeled inside the control box. Conduit
Resumen del contenido incluido en la página 15
4. Quick service guide MODEL: CMA 180 HIGH TEMP TECHNICAL ISSUE CAUSE SOLUTION Door magnetic reed switch problem Faulty magnetic reed switch Check wire connections inside control box Contact factory for new retrofit, corner P/N 00566.10 straight P/N 00566.20 Door mechanical switch problem Switch alignment issue Align switch Switch button broke Replace switch, P/N00562.00 Delimer switch is in OFF position Flip to NORMAL position Loose wire connections Check and crimp co
Resumen del contenido incluido en la página 16
5. INITIAL PARTS KIT P/N 1100.17 P/N DESCRIPTION NO. REQ’D 00121.18 CMA-180 Drain Stopper O Ring 1 00200.10 Pump Assy 110/220V 60 Hz (Open) 1 00206.00 Pump Seal Kit 1 00302.19 CMA-180 Buna Gasket (#302.17) 1 00304.17 CMA-180 Wash Spray Arm 1 00304.19 CMA-180 Rinse Arm W/Bearing 1 00308.17 CMA-180 Rinse Arm SS End Plug 1 00308.50 Spray Arm End Plug SS 1 00363.00 Spray Base Lock Pin 1 00404.85 Contactor 208.240V 20AMP 1 00405.00
Resumen del contenido incluido en la página 17
6. Auto-Fill Solid State Timer Pre-selected delay period can be adjusted by turning securely small flat screwdriver. Since the range of this solid state timer is from 6 seconds to 240 seconds, you should adjust delay by small increment. Removal of input power will reset the control. AUTO-FILL SWITCH 6 L2 T2 WATER L1 T1 SOLENOID VALVE 23 1 MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page 16 WASH PUMP CONTACTOR
Resumen del contenido incluido en la página 18
7. Wire Diagram MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page 17
Resumen del contenido incluido en la página 19
8. Wire Diagram for CMA-180 Booster Only L2 T2 GROUND RINSE SIGNAL { DETERGENT { L1 T1 L3 T3 GND L3 L2 T2 L2 L1 T1 L1 L3 T3 L2 T2 T1 L1 HI LIMIT SWITCH 5kW WASH TANK ADJ. 12kW PUMP THERMOSTAT HEATER MOTOR BOOSTER HEATER MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 Page 18 BOOSTER HEATER WASH PUMP HEATER CONTACTOR CONTACTOR CONTACTOR