Resumen del contenido incluido en la página 1
FrameSaver DSL 9783
USER’S GUIDE
Document No. 9783-A2-GB20-00
July 2000
Resumen del contenido incluido en la página 2
Copyright 2000 Paradyne Corporation All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave. N.
Resumen del contenido incluido en la página 3
Contents About This Guide Purpose and Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Document Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Product-Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix Conventions Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x 1 About the FrameSaver DSL Unit
Resumen del contenido incluido en la página 4
Contents 4 Configuration Options Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Using the Easy Install Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Setting Up So the Router Can Receive RIP . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 Entering System Information and Setting the System Clock . . . . . . . . . . . 4-6 Configuration Option Tables . . . . . . . . . .
Resumen del contenido incluido en la página 5
Contents 6 Operation and Maintenance Displaying System Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 Viewing LEDs and Control Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 LED Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 Control Lead Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6 Device Messages . . . . . . . . . .
Resumen del contenido incluido en la página 6
Contents 8 Troubleshooting Problem Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 Resetting the Unit and Restoring Communication . . . . . . . . . . . . . . . . . . . 8-3 Resetting the Unit from the Control Menu . . . . . . . . . . . . . . . . . . . . . . . 8-3 Resetting the Unit By Cycling the Power . . . . . . . . . . . . . . . . . . . . . . . . 8-3 Restoring Communication with an Improperly Configured Unit . . . . . 8-4 Tr
Resumen del contenido incluido en la página 7
Contents 10 Setting Up Network Health for FrameSaver Devices Installation and Setup of Network Health . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2 Discovering FrameSaver Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3 Configuring the Discovered Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-4 Grouping Elements for Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-5 Generating Reports
Resumen del contenido incluido en la página 8
Contents C Connectors, Cables, and Pin Assignments Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1 DSL Network Interface Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2 COM Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3 Standard EIA-232-D Crossover Cable . . . . . . . . . . . . . . . . . . . . . . . . . . C-4 Data Por
Resumen del contenido incluido en la página 9
About This Guide Purpose and Intended Audience This document contains information that applies to the FrameSaver DSL 9783. It is intended for system designers, engineers, administrators, and operators who are familiar with the functional operation of digital data communications equipment and frame relay networks. Document Organization Section Description Chapter 1 About the FrameSaver DSL Unit. Identifies how the FrameSaver DSL 9783 fits into Paradyne’s Service Level Management (SLM) solution, a
Resumen del contenido incluido en la página 10
About This Guide Section Description Chapter 8 Troubleshooting. Provides device problem resolution, alarm, and other information, as well as troubleshooting and test procedures. Chapter 9 Setting Up OpenLane for FrameSaver Devices. Identifies where installation and setup information is located and how FrameSaver units are supported. Chapter 10 Setting Up Network Health for FrameSaver Devices. Describes setup of Concord’s Network Health application so reports can be created for FrameSaver units,
Resumen del contenido incluido en la página 11
About This Guide Product-Related Documents Document Number Document Title Paradyne FrameSaver Documentation: 9000-A2-GB20 Configuring Frame Relay Service Over DSL 9783-A2-GN10 FrameSaver DSL 9783 Installation Instructions 9783-A2-GL10 FrameSaver DSL 9783 Quick Reference Paradyne Hotwire Documentation: 8335-A2-GB20 Hotwire ATM Line Cards, Models 8335 and 8365, User’s Guide 8820-A2-GN20 Hotwire 8820 GranDSLAM Installation Guide Paradyne OpenLane NMS Documentation: 7800-A2-GZ41 OpenLane 5.x Service
Resumen del contenido incluido en la página 12
About This Guide Conventions Used Convention Used When Used Italic To indicate variable information (e.g., DLCI nnnn). Menu selection sequence To provide an abbreviated method for indicating the selections to be made from a menu or selections from within a menu before performing a procedural step. For example, Main Menu →Status →System and Test Status indicates that you should select Status from the Main Menu, then select System and Test Status from the Status menu). (Path:) To provide a check
Resumen del contenido incluido en la página 13
About the FrameSaver DSL Unit 1 This chapter includes the following: System Overview FrameSaver DSL Features and Benefits FrameSaver DSL Feature Sets — Basic Features — Advanced SLV Features OpenLane SLM System System Overview Our system solution consists of: FrameSaver DSL (Digital Subscriber Line) unit Hotwire ATM Line Card in the Hotwire 8820 GranDSLAM OpenLane SLM (Service Level Management) system This solution provides increased manageability, monitoring, and diagnostics so
Resumen del contenido incluido en la página 14
About the FrameSaver DSL Unit FrameSaver DSL Features and Benefits Large-scale deployment of frame relay services over DSL-based access networks is possible with the innovative FrameSaver DSL, which provides important advantages for frame relay service providers. Remote diagnostic and service level management (SLM) functionality allows service providers to install the unit and verify operation quickly and reliably. Superior fault isolation and test capabilities allow both the Competitive Loc
Resumen del contenido incluido en la página 15
About the FrameSaver DSL Unit Advanced SLM and reporting feature set includes all of the diagnostic feature set, plus: — CIR relationship statistics — FDR/DDR (Trueput) reporting — Continuous real-time latency report — RMON2 alarms and proactive thresholds — FTP user history poller for graphical and historical reporting Performs FRF.8 (transparent mode) for frame to ATM conversion ATM OA&M loopbacks LMI Trace & Display Routing Table Display Router independent operation Ethernet por
Resumen del contenido incluido en la página 16
About the FrameSaver DSL Unit An advanced SLM and reporting feature set can be activated on command with the SLV key. In the base configuration, comprehensive Layer 1 and 2 instrumentation allows service providers to isolate, diagnose, and correct problems remotely from their NOC. FR NSPs can expect fewer truck rolls and faster service turn-up times. FrameSaver DSL carries forward the end-to-end, nondisruptive loopback capabilities found in all FrameSaver products, allowing quick verification of
Resumen del contenido incluido en la página 17
POWER ALARMS C LOCK S ER I A L AC LA N/WA N S LOT A MCC A LARM 2 4 6 8 A 10 12 14 16 18 B SER IAL A LAR M 1 3 5 7 9 B 11 13 15 17 CLOCK SMC M A B Fan Majo r Minor WARIN NG! WARIN NG P OW ER ENTR T UIN T: L Y MO I DA ULE POWER ENTRY MODU LE RI LEF GHT UNIT L I NE NE B RIG LEFT HT UNI UNI TT: L LI INE N A EB ! : : I I I PO OV W ER MU ST BE D SC IN ONN EC T ED EN AT THE SO UR CE POWER MU ST B E DISCO NNECT ED A T TH E SO RC U E BEFORE R E M N G ORINST ALL G THIS P WR T RY MO DUL E BEFORE REMO
Resumen del contenido incluido en la página 18
About the FrameSaver DSL Unit FrameSaver DSL Feature Sets Depending upon the model ordered, the FrameSaver DSL unit has the basic FrameSaver frame relay and diagnostic capability, or it is enhanced with additional SLV (Service Level Verification) reporting capability. These are referred to as feature sets, which provide different levels of intelligence for monitoring, managing, and reporting performance of the unit. The two feature sets include: Basic Feature Set. Models with this feature set
Resumen del contenido incluido en la página 19
About the FrameSaver DSL Unit To obtain an activation certificate, provide the model number (9783), your OpenLane system license key number, and the number of FrameSaver units whose SLV capability is to be activated. When you receive your certificate, it will include an Activation Certificate number, the Feature Group Number for the additional SLV features (Feature Group 2), your OpenLane license key number, and the number of device activations (license keys) ordered. When ready to activate SLV
Resumen del contenido incluido en la página 20
About the FrameSaver DSL Unit Basic Features The FrameSaver DSL unit provides the following features: Easy Installation. When AutoBaud is used, no configuration is required. SNMP options may be modified if desired to provide security and enable traps. Frame Relay Aware Management. Supports diagnostic and network management features over the frame relay network. The unit’s frame relay capability also supports: — Inband management channels over the frame relay network using dedicated PVCs. — U