SEALEDGAS COOKTOPS
Models: MGC6430 & MGC6536
IMPORTANT: Dimensions Shown in Both Inches and Centimeters.
IMPORTANT: Be sure the appliance being installed is equipped for the gas to be supplied. Refer to serial plate on
underside of burner box for this information. Do not attempt to convert this appliance for use with a gas other than the type
specified.
DIMENSIONS
inches cm
A 28 1/2 + 1/16 72.4 + 0.2
B 19 15/16 + 1/16 50.6 + 0.2
C 21/8 + 1/16 5.4 + 0.2
D 51/4 + 1/16 13.3 + 0.2
E 30 + 1/16 76.2 +
Inhaltszusammenfassung zur Seite Nr. 2
Location Of Your Maytag Important Preparation Appliance Suggestions Locate this appliance away from combustible materials 1. Chamfer all exposed edges of decorative laminate to such as window curtains and combustible wall prevent damage from chipping. decorations. 2. Radius corners of cutout and file to insure smooth edges and prevent corner cracking. Recommend Minimum horizontal clearance between the edge of the 1/4" or 3/8" diameter drill in each corner. appliance and combustible construction
Inhaltszusammenfassung zur Seite Nr. 3
Checkthecooktop serialplatetoseeif thecooktop is All supply piping, except as noted, should use common approved forinstallation inmobile homes and/or National Pipe Thread (N.P.T.). For all pipe connections recreational parktrailers.Serialplateislocated onthe use an approved pipe joint compound resistant to the bottom of theunit. action of LP gas. Ifapproved, thefollowing itemsareapplicable: CAUTION: Warranty is void on Maytag equipment installed other than as recommended by manufacturer. Mobile
Inhaltszusammenfassung zur Seite Nr. 4
Connecting Appliance To Gas Supply Apply a non-corrosive leak detection fluid to all joints and A QUALIFIED SERVICE TECHNICIAN OR GAS fittings in the gas connection between the supply line APPLIANCE INSTALLER MUST MAKE THE GAS shut-off valve and the cooktop. Include gas fittings and joints in the cooktop if connections were disturbed SUPPLY CONNECTION. Leak testing of the appliance shall be conducted by the installer during installation. Check for leaks! Bubbles appearing around fittings and con
Inhaltszusammenfassung zur Seite Nr. 5
2. IF THIS UNIT WILL HAVE A MAYTAG MODEL ILLUSTRATIVE GAS SUPPLY PIPING MEW6500 or MEW5500 SERIES ELECTRIC WALL (WALL OVEN INSTALLED BELOW 30" COOKTOP) OVEN INSTALLED BELOW THIS COOKTOP. NOTE 1: This appliance and its gas and electrical supply •,,_,_,===__._ / /..r sources must be installed before the wall oven is installed. _1 / BURNER BOX See illustration (Electrical Wiring Information - page 7; _tiigl ./ _ (REAR OF APPLIANCE) figure 6) for recommended electrical supply source locations. :::.:
Inhaltszusammenfassung zur Seite Nr. 6
Alternative Piping Methods To Pressure Testing The appliance must be isolated from the gas supply Connect Appliance To Gas Supply piping system by closing its individual manual shut-off A TRAINED SERVICE TECHNICIAN OR GAS valve during any pressure testing of the gas supply piping APPLIANCE INSTALLER MUST MAKE THE GAS system at test pressures equal to or less than 1/2 pounds SUPPLY CONNECTION. Leak testing of the per square inch (3.5 kPa). appliance shall be conducted by the installer This applia
Inhaltszusammenfassung zur Seite Nr. 7
Electrical Wiring Information can be located as is convenient in this left wall or in the This appliance is equipped with a grounded type power cord. A grounded outlet must be provided. It is corresponding right wall. recommended, for convenience, the outlet be located In planning any installation, note that the free length of (with reference to figure 6) as in A or B, below: this appliance's power cord, extending beyond a point 3-3/4" (9.53 cm) left of the nominal center of the rear wall A. If
Inhaltszusammenfassung zur Seite Nr. 8
Installation Of LP Orifice Spud Converting Appliance For Use With LP Gas 0' 91CZJ_ 1 WARNING Propane conversion is to be performed by a MAYTAG AUTHORIZED SERVICER (or other qualified agency) in accordance with the manufacturer's instructions and all © codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in © serious injury or property damage. The qualified agency i"% II performing this work assumes responsibility for this conversion. ARTIt 9215
Inhaltszusammenfassung zur Seite Nr. 9
B. INVERT CAP IN APPLIANCE PRESSURE REGULATOR (See figure 11) With the appliance installed, the appliance regulator After adjusting the screw the burner should produce a should be located as shown in figure 3, 4 or 5. stable, steady blue flame of minimum size. The setting should be checked by turning knob from high to low CONVERSION OF APPLIANCE several times without extinguishing the flame. APPLY DOWNWARD FINGER PRESSURE PRESSURE REGULATOR ATDISC EDGES TO This operation will automatically provi
Inhaltszusammenfassung zur Seite Nr. 10
4 BURNER MODEL (30" WIDE) To Convert Appliance For Use With Natural Gas Electrical power and gas must be turned WARNING off prior to conversion. If this appliance has been converted for use with LP gas, each of the following modifications must be performed to convert the unit back to natural gas. A. REPLACE ALL ORIFICE SPUDS. 1. Perform Steps 1 and 2 on page 8. 2. Perform Step 3 on page 8. 3. For Step 4: Locate the brass natural gas orifice spuds that were originally installed in this appliance
Inhaltszusammenfassung zur Seite Nr. 11
Burner Performance shutters. When operating properly, burners should CAUTION: Never cover control knobs or surrounding produce clearly defined, even blue flames. If the flames control surface with utensils, towels, or other objects. have yellow tips or are hazy and otherwise appear to Never obstruct free air passage past the control knobs. have insufficient air, obtain the services of a qualified The knob openings have been sized to properly control air service technician. Some yellow tipping on