Inhaltszusammenfassung zur Seite Nr. 1
INSTRUCTIONS AND
RECOMMENDATIONS FOR THE USE,
INSTALLATION AND MAINTENANCE OF
BUILT-IN GAS CERAMIC HOBS
Dear customer,
thank you for buying one of our products.
We are sure that this new, modern, functional and practical appliance, made using the finest quality
materials, will fully satisfy your requirements. This new appliance is very easy to use, but in order to
obtain the best results, we strongly recommend that you read this booklet carefully before use.
These instructions are valid exclusiv
Inhaltszusammenfassung zur Seite Nr. 2
DESCRIPTION OF HOBS MODEL: GKS 11742.0-35 F-UL 1 Ultra rapid gas burner of 10300 Btu/h 3 Semirapid gas burner central front of 4350 Btu/h 6 Enamelled steel pan support for ultra rapid burner 7 Enamelled steel pan support 2F 8 Enamelled steel pan support wok (only on ultra rapid gas burner) 10 Burner n° 1 control knob 12 Burner n° 3 control knob Attention: this appliance has been manufactured for domestic use only and it employment by private person. 2
Inhaltszusammenfassung zur Seite Nr. 3
SAFE GUARD INSTRUCTIONS 1) SAFE GUARD INSTRUCTIONS For all appliances: - the product shall be installed according with the a statement that the installation must conform with local codes or, in absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. - The product must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. - The appliance and its individual shutoff valve must be disconnected
Inhaltszusammenfassung zur Seite Nr. 4
USE 2) BURNERS Burners Power ratings Pan Ø in cm A diagram is screen-printed above each knob on the front panel. This diagram indicates to which Ultra rapid 10300 Btu/h 24 ÷ 26 burner the knob in question corresponds. After Semirapid 4350 Btu/h 16 ÷ 18 having opened the gas mains or gas bottle tap, light the burners as described below: - manual ignition WARNINGS: Push and turn the knob corresponding to the - burners with flame failure device may only be required burner in an anticlockwise direct
Inhaltszusammenfassung zur Seite Nr. 5
USE Notes: use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The room must therefore be well ventilated. Intensive and lengthy use of the appliance may require additional ventilation. This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed. WARNING! NEVER use this appliance as a space heater to heat or warm the room. Doing so may result in carbon monoxide poisoning and overheating ot the ov
Inhaltszusammenfassung zur Seite Nr. 6
CLEANING CAUTION: - Traces of liquid spilled from pans can be before cleaning the appliance, disconnect it eliminated with vinegar or lemon juice. from the gas and electricity supplies. - Never allow sugar or sugary foods to fall on the hob while cooking. Should this occur, switch off the hob and clean it immediately with hot water, 3) WORKTOP using a scraper on hot spills. If you wish to maintain the shine of the ceramic - As time goes by metallic reflections, colouring or surface, treat the gl
Inhaltszusammenfassung zur Seite Nr. 7
CLEANING The enamelled grids, enamelled covers “A”, “B” and - If the opening and closing of any valve is awkward, do not force it but request urgent “C”, and burner heads “M” (see fig. 4 and 4/A) must intervention by the technical assistance also be washed and the ignition elements “AC” and service. safety cut-off sensors “TC” (see fig. 5) must be - Do not use jets of steam to clean the cleaned. Do not wash them in the dishwasher. appliance. Cleaning operations must be carried out when the - T
Inhaltszusammenfassung zur Seite Nr. 8
INSTALLATION TECHNICAL INFORMATION 5) FIXING THE HOT PLATE The hot plate has a special seal which prevents FOR THE INSTALLER liquid from getting into the cabinet. Strictly comply Installation, adjustments of controls and with the following instructions in order to correctly maintenance must only be carried out by a apply this seal: qualified engineer. - detach the seals from their backing, checking Incorrect installation may cause damage to that the transparent protection still adheres to the pe
Inhaltszusammenfassung zur Seite Nr. 9
INSTALLATION The transition piece on the supply side of the 6) ROOM VENTILATION regulator must be provided by the installer. To ensure correct operation of the appliance, it is important to ensure that the room where the hot Unions compatible with the hose fittings must be plate is installed has sufficient ventilation. used and connections tested for gas leaks. Ensure the supply connection point is accessible 7) GAS CONNECTION with the appliance installed. Natural Gas and Propane Gas Warning: en
Inhaltszusammenfassung zur Seite Nr. 10
INSTALLATION When the appliance is connected straight to the 8) ELECTRICAL CONNECTION electricity main: The electrical connections of the appliance - install an omnipolar circuit-breaker between the must be carried out in compliance with the appliance and the electricity main. This circuit- provisions and standards in force. breaker should be sized, in compliance with Before connecting the appliance, check that: current installation regulations. - the electrical capacity of the mains supply and
Inhaltszusammenfassung zur Seite Nr. 11
INSTALLATION - Fix the hob with the proper brackets “S” and turn 9) FIXING THE HOT PLATE the screw “F” until the bracket “S” stick on the top The hot plate has a special seal which prevents (fig. 10). liquid from infiltrating into the cabinet. Strictly - The prospective walls (left or right) that exceed the comply with the following instructions in order to working table in height must be at a minimum correctly apply this seal: distance from the cutting as mentionned both in - detach the seals f
Inhaltszusammenfassung zur Seite Nr. 12
ADJUSTMENTS Always disconnect the appliance from the - Insert a small screwdriver “D” into hole “C” (fig. 11) electricity main before making any adjustments. and turn the throttle screw to the right or left until All seals must be replaced by the technician at the burner flame has been adequately regulated to the end of any adjustments or regulations. the “Reduced rate” position. Our burners do not require primary air Check that the flame does not go out when the adjustment. knob is sharply swi
Inhaltszusammenfassung zur Seite Nr. 13
CONVERSIONS paragraphs 10. The technician must reset any 11) REPLACING THE INJECTORS seals on the regulating or pre-regulating devices. The burners can be adapted to different types of The envelope with the injectors and the labels can gas by mounting injectors suited to the type of gas be included in the kit, or at disposal to the in question. To do this, first remove the burner tops authorized customer Service Centre. using a wrench “B”. Now unscrew injector “A” (see For the sake of convenienc
Inhaltszusammenfassung zur Seite Nr. 14
SERVICING Always disconnect the appliance from the Greasing the taps (see fig. 17) electricity and gas mains before proceeding If a tap becomes stiff to operate, it must be with any servicing operation. immediately greased in compliance with the following instructions: 12) REPLACING COMPONENTS - remove the tap. Replacement of the components housed inside - Clean the cone and its housing using a cloth the appliance: remove the trivets and the burners soaked in diluent. from the upper part of the
Inhaltszusammenfassung zur Seite Nr. 15
TECHNICAL DATA ON THE DATA LABEL 4 BURNERS (110) PROPANE HD - 5 = 11 inches water column NATURAL GAS = 7 inches water column Σ Qn Natural Gas = 29300 Btu/h Σ Qn Propane HD - 5 = 29300 Btu/h Voltage = 120 V AC Frequency = 60 Hz 15
Inhaltszusammenfassung zur Seite Nr. 16
TECHNICAL ASSISTANCE AND SPARES Before leaving the factory, this appliance was tested and regulated by specially qualified experts in order to guarantee the best operating results. The original spare parts can be found only in our Technical Assistance Centres and authorised shops. Every repair or regulation operation which should become subsequently necessary must be carried out with the utmost care and attention by qualified personnel. This is why we recommend that you always contact the Deal
Inhaltszusammenfassung zur Seite Nr. 17
Kuppersbusch USA 1883 Massaro Blvd. Tampa, FL 33619 Toll: (800) 459-0844 P: 813-288-8890 F: 813-288-8604