Inhaltszusammenfassung zur Seite Nr. 1
F116 (Series 16000) Self-Contained
Ductable Commercial Air Cleaner
PRODUCT DATA
FEATURES
• Variety of filter configurations available to customize the
air cleaner for any application.
• Three-speed direct drive forward curve blower/motor
3
circulates up to 2500 cfm (72 m /min) for large areas.
• Negative and positive pressure rooms can be created with
the air cleaner.
• Charcoal, permanganate and zeolite (CPZ™) disposable
modules can be used for odor control.
• Two stage and three stage air cl
Inhaltszusammenfassung zur Seite Nr. 2
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER SPECIFICATIONS Blower/Motor: IMPORTANT • three speed direct drive forward curve The specifications given in this publication do not • 1070 RPM nominal speed include normal manufacturing tolerances. Therefore, • thermal circuit breaker this unit may not exactly match the listed specifications. This product is tested and calibrated NOTE: Oil annually. under closely controlled conditions, and some minor differences in performance ca
Inhaltszusammenfassung zur Seite Nr. 3
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER Table 2. F116 (Series 16000) Maximum Starting Loads. Power: Hardwire Fe an SettingVs oltag Ampere HV IGH 1A 20 23 Approvals: UL and cUL pending. MV EDIUM 1A 20 15 Dimensions: LV OW 1A 20 15 See Fig. 1 and 2 for dimensions. Replacement Parts and Accessories: See Parts List on page 14. Air Volume, Internal Static Pressure and Installation Weight: Air volume, internal static pressure and installation weight are based on the air clea
Inhaltszusammenfassung zur Seite Nr. 4
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER Table 4. F116 (Series 16000) Filter Description. Dimensions in Filter Es fficiency Comment inches (mm) 24 x 24 x 4 Disposable pleated synthetic Prefilter 30% to 40% (610 x 610 x 102) fiber in beverage board frame. 24 x 24 x 12 99.97% at 0.3 micron at In metal frame with aluminum HEPA 3 (610 x 610 x 305) 1600 cfm (49 m /min) pleat separators in the media. 24 x 24 x 12 95% at 0.3 micron at 1800 D.O.P. 3 (610 x 610 x 305) cfm (52 m
Inhaltszusammenfassung zur Seite Nr. 5
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER FRONT VIEW 7/8 (22) FLANGE TOP 13-1/2 (343) 16 TYP (406) 24-1/4 (616) 48 10 (1219) (254) 5 TYP 22-1/4 (127) (565) 7 12-1/8 (308) (178) 3/8 THREADED INSERT HOLE FOR HANGING INSTALLATION 26 (660) 26 (660) SORBENT MODULES HEPA, D.O.P. OR ASHRAE FILTER PREFILTER ELECTROSTATIC PRECIPITATOR M10810 COLLECTING CELLS Fig. 1. Approximate dimensions of two stage filtering model in in. (mm). Please Note : Electrostatic P
Inhaltszusammenfassung zur Seite Nr. 6
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER FRONT VIEW 7/8 (22) FLANGE TOP 13-1/2 (343) 16 TYP (406) 24-1/4 (616) 64 (1626) 10 5 TYP (254) 17 (127) (432) 7 12-1/8 (308) 21-1/4 (178) (540) 3/8 THREADED INSERT 26 HOLE FOR A HANGING INSTALLATION (660) 26 (660) SORBENT MODULES CAN BE POSITIONED IN EITHER SPACE OR IN BOTH SPACES FOR DOUBLE PASS PREFILTER D.O.P. OR ASHRAE FILTER CAN BE POSITIONED IN EITHER SPACE OR IN BOTH SPACES FOR DOUBLE PASS ELECTROSTATIC PREC
Inhaltszusammenfassung zur Seite Nr. 7
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER FAN PERFORMANCE Static Pressure DIRECT DRIVE BLOWER (12-5/8 x 9-1/2 WHEEL) TESTED WITH 3 FT (0.9M) OUTLET DUCT The F116 (series 16000) uses a forward curve blower/ 2.200 motor. The electrical current draw is determined by 2.000 combining the air volume to be moved with the filter and ducting static pressure. 1.900 1.800 IMPORTANT 1.700 Motor overload will occur if the combined filter and ducting static pressure is less than 1.2"
Inhaltszusammenfassung zur Seite Nr. 8
Non- Smoking F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER M7783 Fig. 4. Positioning air cleaners at the far end of the restaurant smoking section to draw the smoke away from the nonsmoking section. M7782 Fig. 5. Positioning air cleaners to create a negative pressure in polluted spaces and creating a positive pressure in nonpolluted areas. Use this positioning in in-plant offices and hospitals. 68-0200-2 Revised 10-07 8 Smoking Section
Inhaltszusammenfassung zur Seite Nr. 9
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER TOP VIEW AIR CLEANER CURTAIN AIR INPUT CONVEYOR DRYER HOOD CLEANER SIDEVIEW AIR CLEANER CURTAIN OUTPUT DRYER INPUT M10797 M10795 Fig. 6. Positioning air cleaner for printing shop, brazing, Fig. 8. Positioning air cleaner to remove pollutants from a soldering or gluing vapor control. conveyor feed process such as screen printing. POSITIVE PRESSURE ROOMS SUCH AS IN PLANT SATELLITE OFFICES AIR AIR CLEANER CLEANER AIR AIR CLEAN
Inhaltszusammenfassung zur Seite Nr. 10
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER AIR CLEANER AIR CLEANER STATIONARY FLEXIBLE M10799 Fig. 10. Positioning air cleaner for suspended side draft applications. DO NOT INSTALL WHERE THERE IS HEAVY OIL SMOKE, COOKING, HEAVY WELDING OR HEAVY CUTTING. AIR CLEANER AIR CLEANER DO NOT INSTALL WHERE THERE IS HEAVY OIL SMOKE, COOKING, HEAVY WELDING OR HEAVY CUTTING. M10801 M10800 Fig. 11. Connecting air cleaner directly to a canopy hood Fig. 12. Positioning air cl
Inhaltszusammenfassung zur Seite Nr. 11
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER FASTEN SECURELY TO STRUCTURAL SUPPORT SYSTEM Use a square-to-round or square-to-square connection I.E. BAR JOIST, CONCRETE SLAB, TIMBER FRAMING, ETC. when attaching the air cleaner outlet to the blower discharge flange. See Fig. 16. The outlet connection can ALL EXTERNAL HARDWARE be used with a Y-branch, distribution box or manifold as CHAIN FURNISHED BY OWNER. THREADED HEX BOLT AIR CLEANER ROD LOCK WASHER JAM NUT Y-BRANCH
Inhaltszusammenfassung zur Seite Nr. 12
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER Maintenance SERVICE 1. Remove the air cleaner cover and set it aside. 2. Remove the prefilter and primary filters. IMPORTANT 3. Locate the blower/motor and apply 3 to 4 drops of light Air cleaners and components are susceptible to weight oil to the shaft bearings. damage. Take care when working with them to avoid equipment damage. NOTE: Shaft bearings need oil once a year or every 3 or 4 months when the air cleaner operates 24 Th
Inhaltszusammenfassung zur Seite Nr. 13
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER TROUBLESHOOTING WARNING Electrical Shock Hazard Can cause personal injury or equipment damage. The following procedures expose hazardous live parts. Disconnect power supply between checks and proceed carefully. CAUTION The following instructions are for use by only qualified personnel. See Table 5 for troubleshooting procedures. Table 5. Troubleshooting the F116 (Series 16000) Air Cleaner. So ymptom What to d * Check wiring for l
Inhaltszusammenfassung zur Seite Nr. 14
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER PARTS LIST Refer to Table 6 and Fig. 18 for the parts list and exploded view. Table 6. F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner Parts List. Order Reference Fn ig. Reference No.Dy escriptio Pack Qt Number No. 1 P6 refilter 10 Box of39 200020 86003 2 Primary Filters: H1 EPA filter (99.97%) 33 2000198 86002 D1 .O.P. filter (95%) 34 2000195 86002 A1 SHRAE dust spot filter (95%) 35 2000196 86002 A1 SHRAE dus
Inhaltszusammenfassung zur Seite Nr. 15
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER 1 2 (SORBENT MODULES) 1 (PREFILTER) 2 (HEPA, D.O.P. OR ASHRAE FILTERS) 2 (ELECTROSTATIC PRECIPITATOR 1 COLLECTING CELL) TWO STAGE MODELS WILL HAVE ONLY ONE PRIMARY FILTER AREA. M10812 Fig. 18. Exploded view of F116 (series 16000) self-contained ductable commercial air cleaner components. Please Note : Electrostatic Precipitator Collecting Cells are no longer available. 15 68-0200-2
Inhaltszusammenfassung zur Seite Nr. 16
F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER LIMITED TWO-YEAR WARRANTY Air-Pure Systems warrants its air cleaner products to be free from defects in workmanship or materials under normal use and service, for a period of two (2) years from the date of purchase by the originial end-user. If at anytime during the warranty period the product is defective or malfunctions, Air-Pure Systems, through the distributor or dealer, from which the product was purchased, or through an aut