Safety Instructions Improper handling can cause serious damage to the appliance and/or to the user. This portable air conditioner is not intended for use by children. Children should be supervised to ensure that they do not play with this product. Electrical Safety General Safety 1. This unit is designed for indoor use only. 1. This portable air conditioner is not 2. Do not use the unit in extremely humid or intended to be used by children. wet environments. 2. Do not allow c
Inhaltszusammenfassung zur Seite Nr. 3
Table of Contents Safety Instructions.............................................. 2 Introduction............................................................................................ .............................. 5 Parts Identification.................................................................................................................. 6 Installation Carbon Filter Installation....................................................................................... 7 Exh
Inhaltszusammenfassung zur Seite Nr. 4
4
Inhaltszusammenfassung zur Seite Nr. 5
Introduction Thank you for purchasing this EdgeStar portable air conditioner. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will provide the customer support needed to nurture that relationship. This manual contains important information regarding the proper installation, use and maintenance of your portable air conditioner. Following this manual will ensure that your product will work at its peak performan
Inhaltszusammenfassung zur Seite Nr. 6
Parts Identification Front Back 1. Display 7. Cord storage 2. Control panel 8. Air pre-filter 3. Buttons 9. Air inlet (evaporator) 4. Front air vent 10. Exhaust air outlet 5. Handle 11. Air inlet (condenser) 6. Caster 12. Water stopper/drainage point Accessories 13. Flat adapter - for insertion over hose and into window kit. 14. Exhaust hose 15. Active carbon filter 16. Extendable window kit 17. Drain tube for continuous drainage 18. Remote control 6
Inhaltszusammenfassung zur Seite Nr. 7
Installation – Activated Carbon Filter Instructions to install the carbon filter 1. Remove the pre-filter frame from the unit. 2. Remove the activated carbon filter from its plastic bag. 3. Place the activated carbon filter on the back of the unit. 4. Install the pre-filter frame to the unit. Note: Replace the activated carbon filter every 2-3 months or as needed. 7
Inhaltszusammenfassung zur Seite Nr. 8
Installation – Exhaust Hose Follow the instructions below to install the window kit and exhaust hose. Window kit 20” FIG.5 1. Open the window and insert the window kit to cover the open gap. Next, slide the window across so that the kit is held securely. You may need to adjust the size of the window kit and secure it with screws. This technique may also be used for sash windows. Note: Take care to secure your window against intruders. 2. Thread the exhaust hose to the air outl
Inhaltszusammenfassung zur Seite Nr. 9
Installation – Exhaust Hose Use the hose provided and attach the exhaust hose to FIG.8 the back of the air conditioner. Avoid kinks and bends in the exhaust hose as this will cause the unit to work less efficiently. Improper setup may cause the unit to FIG.9 overheat and shut off. Figs. 8 & 9 show the correct position The hose may be extended from 11” to 59.” For maximum efficiency use the shortest length possible. FIG.10 WARNING! The length of the exha
Inhaltszusammenfassung zur Seite Nr. 10
POWER TIMER UP A/C Water Operation – Using the Control Panel Control Panel Parts 16 15 17 14 13 12 1 11 2 10 3 9 4 8 5 6 7 FIG.12 1. Power button 9. High fan speed indicator 2. Timer button 10. Heat mode indicator 3. Timer operation indicator 11. Fan mode indicator 4. Temperature up button 12. Cooling mode indicator 5. Compressor indicator 13. Automatic mode indicator 6. Water Full indicator 14. Mode (function) option button 7. Temperature down button 15. Fan speed button 8. Low fan
Inhaltszusammenfassung zur Seite Nr. 11
Operation – Using the Control Panel Setting the Temperature 1. Press the ‘Up’ or ‘Down‘ buttons to set the temperature you desire. 2. The display window will show the temperature you set as you press the 'Up' or ‘Down' buttons. Otherwise, it will always show the ambient temperature. o The default temperature of this machine is: 75 F for cooling Note: Temperature control only works in cooling and heating modes. Setting the Fan Speed 1. Press the ‘Speed’ button to choose between h
Inhaltszusammenfassung zur Seite Nr. 12
Operation – Using the Remote Control All the control panel functions can also be set with the remote control. 1 1. LED Indicator – Lights up when 5 2 you press any of the buttons. 2. Power Button – Used to power the unit on or off 3 3. Mode Button – Used to change 6 between auto, cooling, heating, or fan modes. 4 4. Timer Button – Used to set the 7 timer function. 5. Up Button – Used to increase the temperature. Note: The 6. Down Button – Used to decrease r
Inhaltszusammenfassung zur Seite Nr. 13
Maintenance – Water Drainage This portable air conditioner is designed to exhaust most or all water dehumidified from the air. In high humidity situations, the internal water reservoir may fill. If the reservoir is full, both the compressor and motor will stop and the unit will buzz a warning (you can press any button to stop the buzzing). The “Water” indicator will flash to show you that the reservoir is full. The unit will not operate until you drain the water. Please empty the wat
Inhaltszusammenfassung zur Seite Nr. 14
Maintenance – Extending the Drain Tube The drain tube may be extended by adding an extension tube and using a suitable connector. Drain tube FIG.17 Please note 1. The drain must be at or below the outlet level. Original 2. Flashing Comp / Water indicator will drain tube not function in this mode of drainage. 3. This unit will not shut off when an external drain pan/tray is filled. FIG.18 Extended drain tube 4. If you want to extend the water (Outer Diame
Inhaltszusammenfassung zur Seite Nr. 15
Maintenance – Cleaning the Unit Always unplug the air conditioner from the power outlet before cleaning. Clean the air conditioner regularly to maximize performance and efficiency. Cleaning the unit Use a soft damp cloth to wipe the body clean. Use a soft bristle brush to clean between the control panel’s buttons. Never use abrasive chemicals, gasoline, detergents, chemically treated cloths, or other cleaning solvents that may damage the cabinet exterior. Cleaning the pre-filter
Inhaltszusammenfassung zur Seite Nr. 16
Optimizing Performance For Maximum Performance and Efficiency: 1. Do not cover the air outlet (exhaust) while in use. 2. Do not place the unit in front of curtains or drapes- to ensure they do not obstruct the air intake. 3. Minimize the length of the exhaust hose. 4. Make sure the exhaust hose is as straight as possible. 5. Keep curtains, blinds or drapes closed during the sunniest part of the day. 6. Use the timer to operate the unit before it is needed. For example, set the
Inhaltszusammenfassung zur Seite Nr. 17
Troubleshooting My air conditioner is not functioning at all. - The air conditioner may not be receiving electrical power. Make sure the unit is plugged in. - Press the test/reset buttons on the LCDI power cord. - Move the air conditioner to another outlet that is able to provide sufficient power. Check your circuit breaker. (Refer to the rating label on the back of the unit to determine the Amperage draw). Check to see if the Compressor/ Water indicators are flashing. Drain the u
Inhaltszusammenfassung zur Seite Nr. 18
Specifications Description of Product EdgeStar Portable Air Conditioner Model AP10000HW Voltage / Frequency 115 V, 60 Hz Power / Ampere Consumption for 830W / 7.9 A cooling Power / Ampere Consumption for 920W / 8.2 A heating 50 pints/day Maximum Dehumidifying Capacity Refrigerant R22/15.2 OZ Fan speeds 2 (High and Low) Timer 1- 12 hours Net Weight 51 lbs. Dimensions 12 3/8” x 14 1/16” x 27 15/16” (WxDxH) 18
Inhaltszusammenfassung zur Seite Nr. 19
EdgeStar Limited Warranty This EdgeStar product is warranted to be free from defective workmanship and materials for the first year following the date of original purchase. Replacement parts will be supplied free of charge for the first year following the date of original purchase. Labor will be performed free of charge for the first 90 days following the date of original purchase. WHAT IS COVERED: This warranty applies to the original purchaser only, and only covers defects in workm