Inhaltszusammenfassung zur Seite Nr. 1
H8/3937R H8/33937 Series TFP-100B
User System Interface Cable
(HS3937ECH61H)
for E6000 Emulator
User’s Manual
HS3937ECH61HE(B)
Inhaltszusammenfassung zur Seite Nr. 2
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Inhaltszusammenfassung zur Seite Nr. 3
Preface Thank you for purchasing this user system interface cable (HS3937ECH61H) for the Renesas’s original microcomputer H8/3937R H8/3937 series. The HS3937ECH61H is a user system interface cable that connects an H8/300L series E6000 emulator (HS388REPI60H; hereinafter referred to as the emulator) through the expansion board to the IC socket for a TFP-100B package for the H8/3937R H8/3937 series MCU on the user system. i
Inhaltszusammenfassung zur Seite Nr. 4
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station .........................................3 2.2 Connecting User System Interface Cable to User System ................................................5 2.2.1 Installing IC Socket ..........................
Inhaltszusammenfassung zur Seite Nr. 5
Section 1 Configuration CAUTION Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-100B package IC socket on the user system. Figure 1 shows the configuration of the HS3937ECH61H user system interface cable for the TFP-100B package. Figure 1 HS3937ECH61H User System Interface Cable 1
Inhaltszusammenfassung zur Seite Nr. 6
Table 1 lists the HS3937ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3937ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the TFP-100B package 4 Socket cover 1 For installing an TFP-100B packaged MCU 5 Screws (M2.6 x 12 mm) 4 For fastening cable head 6 Screws (M2.6 x 6 mm) 4 For installing an TFP-100B packaged MCU 7 Documentation 1 User’s manual for HS3937ECH61H (this manua
Inhaltszusammenfassung zur Seite Nr. 7
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before c
Inhaltszusammenfassung zur Seite Nr. 8
E6000 EMULATOR 160kHz 2. [1] After making sure the direction of the expansion board connector labeled E6000 EMULATOR is correct, firmly insert the expansion board connector into the emulator station connector ([1] in figure 2). [2] Connect the expansion board labeled USER INTERFACE CABLE and the user system interface cable body. Emulator station [1] Expansion board Cable body connector [2] Subclock selection User system interface cable Figure 2 Connecting User System Interface Cable
Inhaltszusammenfassung zur Seite Nr. 9
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the expansion board or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable
Inhaltszusammenfassung zur Seite Nr. 10
2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an TFP-100B package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3. 2.2.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.054 N•m or less. If th
Inhaltszusammenfassung zur Seite Nr. 11
Fasten the user system interface cable head to the IC socket for an TFP-100B package on the user system with the four screws (M2.6 x 12 mm; with flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Cable head User system Figure 3 Conn
Inhaltszusammenfassung zur Seite Nr. 12
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body 8
Inhaltszusammenfassung zur Seite Nr. 13
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an TFP-100B package (IC149-100-054-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. Figure 5 Recommended Dimensions for Mount Pad 9
Inhaltszusammenfassung zur Seite Nr. 14
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10
Inhaltszusammenfassung zur Seite Nr. 15
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11
Inhaltszusammenfassung zur Seite Nr. 16
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break
Inhaltszusammenfassung zur Seite Nr. 17
Figure 8 Installing MCU to User System 13
Inhaltszusammenfassung zur Seite Nr. 18
Section 4 Verifying Operation 1. When using the H8/300L series E6000 emulator (HS388REPI60H), turn on the emulator according to the procedures described in the H8/300L Series E6000 Emulator User's Manual (HS388REPI60HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. System Clock (OSC2, 1) When the system clock is selected in the HDI
Inhaltszusammenfassung zur Seite Nr. 19
E6000EMULATOR 160kHz 76.8kHz Figure 9 shows the Expansion I/O board Subclock Selection, and figure 10 shows the location of jumpers P4 and P5. Figure 11 shows the system clock oscillator on the user system interface cable and the subclock input specifications. Subclock selection Figure 9 Expansion I/O board Subclock Selection Figure 10 P4 and P5 Jumpers Figure 11 System Clock Oscillator and Subclock Input Specifications 15 USERINTERFACECABLE E6000
Inhaltszusammenfassung zur Seite Nr. 20
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. To avoid breaking wires in the cable body, do not place heavy or sharp metal objects on the user system interface cable. 4. While the emulator station is connected to the user system with