Inhaltszusammenfassung zur Seite Nr. 1
H8S/2636 Series
FP-128
User System Interface Cable
(HS2636ECH61H)
for E6000 Emulator
User’s Manual
HS2636ECH61HE(B)
Inhaltszusammenfassung zur Seite Nr. 2
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Inhaltszusammenfassung zur Seite Nr. 3
Preface Thank you for purchasing this user system interface cable (HS2636ECH61H) for the Renesas’s original microcomputer H8S/2636 series. The HS2636ECH61H is a user system interface cable that connects an H8S/2636 and H8S/2646 series E6000 emulator (HS2646EPI61H; hereinafter referred to as the emulator) to the IC socket for a FP-128 package for the H8S/2636 series MCU on the user system. i
Inhaltszusammenfassung zur Seite Nr. 4
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures......................................................................4 2.1 Connecting User System Interface Cable to Emulator Station .........................................4 2.2 Connecting User System Interface Cable to User System ................................................6 2.2.1 Installing IC Socket ..........................
Inhaltszusammenfassung zur Seite Nr. 5
Section 1 Configuration CAUTION Use an NQPACK128RD socket (manufactured by Tokyo Eletech Corporation) for the FP-128 package IC socket on the user system. Figure 1 shows the configuration of the HS2636ECH61H user system interface cable for the FP-128 package. 1
Inhaltszusammenfassung zur Seite Nr. 6
Figure 1 HS2636ECH61H User System Interface Cable 2
Inhaltszusammenfassung zur Seite Nr. 7
Table 1 lists the HS2636ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2636ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP-128 package 4 Socket cover 1 For installing anFP-128 packaged MCU 5 Screws (M2 x 10 mm) 4 For fastening cable head 6 Screws (M2 x 6 mm) 4 For installing an FP-128 packaged MCU 7 Guide pins 3 For determining the IC socket location 8 Screwdriver 1 F
Inhaltszusammenfassung zur Seite Nr. 8
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before c
Inhaltszusammenfassung zur Seite Nr. 9
Figure 2 Connecting User System Interface Cable to Emulator Station 5
Inhaltszusammenfassung zur Seite Nr. 10
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable
Inhaltszusammenfassung zur Seite Nr. 11
Guide pins Pin 1 4 projections to apply epoxy resin adhesive to Bottom view of IC soket User system Figure 3 Location Setting of IC Socket 2.2.2 Soldering IC Socket After fastening, solder the IC socket for an FP-128 package to the user system. Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly more solder than the MCU.) 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting.
Inhaltszusammenfassung zur Seite Nr. 12
2.2.4 Fastening Cable Head CAUTION 1. Use the screwdriber provided for tightening screws. 2. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder. 3. If
Inhaltszusammenfassung zur Seite Nr. 13
Figure 4 Connecting User System Interface Cable to User System 9
Inhaltszusammenfassung zur Seite Nr. 14
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 5 Fastening Cable Body 10
Inhaltszusammenfassung zur Seite Nr. 15
2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-128 package (NQPACK128RD: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad. 17.00 ± 0.15 8.50 6.00 3-∅1.00 2.00 ± 0.10 0.50 0.25 Unit: mm Tolerance: ± 0.10 mm Figure 6 Recommended Dimensions for Mount Pad 11 7.00
Inhaltszusammenfassung zur Seite Nr. 16
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7 Dimensions for User System Interface Cable Head 12
Inhaltszusammenfassung zur Seite Nr. 17
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Figure 8 Resulting Dimensions after Connecting User System Interface Cable 13
Inhaltszusammenfassung zur Seite Nr. 18
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket c
Inhaltszusammenfassung zur Seite Nr. 19
Figure 9 Installing MCU to User System 15
Inhaltszusammenfassung zur Seite Nr. 20
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2636 series, turn on the emulator according to the procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins with the MEMORY_FILL command (emulator command). If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. The emulator