Inhaltszusammenfassung zur Seite Nr. 1
H8/36014 Group, H8/36024 Group FP-48B
User System Interface Cable for E6000 Emulator
User’s Manual
HS36014ECH64H
Renesas Microcomputer Development Environment System
Rev.2.00
2003.12.19
Inhaltszusammenfassung zur Seite Nr. 2
Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflam
Inhaltszusammenfassung zur Seite Nr. 3
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. • User system interface cab
Inhaltszusammenfassung zur Seite Nr. 4
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of
Inhaltszusammenfassung zur Seite Nr. 5
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state. The Warranty is Void in the Following Cases: Renesas shall have no liability or legal responsibility for any problems caused by misuse, abuse, misapplication, neglect, improper h
Inhaltszusammenfassung zur Seite Nr. 6
SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an imminently hazardous
Inhaltszusammenfassung zur Seite Nr. 7
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS. 3. Always before connecting any CABLES, make sure that
Inhaltszusammenfassung zur Seite Nr. 8
Preface Thank you for purchasing this user system interface cable (HS36014ECH64H) for the Renesas’s original microcomputer H8/36014series. The HS36014ECH64H is a user system interface cable that connects an H8/36014series E6000 emulator (HS3664EPI61H; hereinafter referred to as the emulator) to the IC socket for a FP-48B package for the H8/36014series MCU on the user system and to the H8/36024 series expansion I/O board (HS36024EIO61H). i
Inhaltszusammenfassung zur Seite Nr. 9
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station (H8/36014 Series)............3 2.2 Connecting User System Interface Cable to Expansion I/O Board (H8/36024 Series).....5 2.3 Connecting User System Interface Cable to User System................................
Inhaltszusammenfassung zur Seite Nr. 10
Section 1 Configuration CAUTION Use an NQPACK048SD socket (manufactured by Tokyo Eletech Corporation) for the FP-48B package IC socket on the user system. Figure 1 shows the configuration of the HS36014ECH64H user system interface cable for the FP-48B package. Figure 1 HS36014ECH64H User System Interface Cable 1
Inhaltszusammenfassung zur Seite Nr. 11
Table 1 lists the HS36014ECH64H components. Please make sure you have all of these components when unpacking. Table 1 HS36014ECH64H Components No. Component Quantity Remarks 1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the FP-48B package 4 Socket cover 1 For installing a FP-48B packaged MCU 5 Screws (M2 x 10 mm) 4 For fastening cable head 6 Screws (M2 x 6 mm) 4 For installing a FP-48B packaged MCU 7 CTS screws (M3 x 6 mm) 2 For fastening the emulator station Guide pins ( 1 mm) 8 ϕ 2 Fo
Inhaltszusammenfassung zur Seite Nr. 12
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station (H8/36014 Series) WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make
Inhaltszusammenfassung zur Seite Nr. 13
Figure 2 Connecting User System Interface Cable to Emulator Station 4
Inhaltszusammenfassung zur Seite Nr. 14
2.2 Connecting User System Interface Cable to Expansion I/O Board (H8/36024 Series) WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system, the emulator product, and the expansion I/O board or will result in PERSONAL INJURY. The USER PROGRAM will be
Inhaltszusammenfassung zur Seite Nr. 15
E6000 EMULATO Expansion I/O board cable Cable body connector CTS screws (M3 x 6 mm) User system interface cable Figure 3 Connecting User System Interface Cable to Expansion I/O Board 6 USER INTERFACE CABL E6000
Inhaltszusammenfassung zur Seite Nr. 16
2.3 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system,
Inhaltszusammenfassung zur Seite Nr. 17
2.3.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-48B package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 4. 2.3.4 Fastening Cable Head CAUTION 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately meas
Inhaltszusammenfassung zur Seite Nr. 18
Fasten the user system interface cable head to the IC socket for a FP-48B package on the user system with the four screws (M2 x 10 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Figure 4 Connecting User System Interface Cable to User System 9
Inhaltszusammenfassung zur Seite Nr. 19
2.3.5 Fastening Cable Body Connect the cable body to the cable head. Figure 5 Fastening Cable Body 10
Inhaltszusammenfassung zur Seite Nr. 20
2.4 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-48B package (NQPACK048SD: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad. 9.10 (min.) 8.10 (max.) 0.50 × 11 = 5.50 ± 0.1 0.1 5.50 = 11 (min.) (max.) 9.10 8.10 0.50 0.50 ± 0.05 0.18 ± 0.05 Unit: mm Figure 6 Recommended Dimensi