PMD-1024HLS Personal Measurement Device™ brand USB-based Digital I/O Module User's Guide Document Revision 4, May, 2005 © Copyright 2005, Measurement Computing Corporation™
Inhaltszusammenfassung zur Seite Nr. 3
Your new Measurement Computing product comes with a fantastic extra — Management committed to your satisfaction! Refer to www.mccdaq.com/execteam.html for the names, titles, and contact information of each key executive at Measurement Computing. Thank you for choosing a Measurement Computing product—and congratulations! You own the finest, and you can now enjoy the protection of the most comprehensive warranties and unmatched phone tech support. It’s the embodiment of our two missions:
Inhaltszusammenfassung zur Seite Nr. 4
Trademark and Copyright Information Personal Measurement Device brand, TracerDAQ, Universal Library, InstaCal, Harsh Environment Warranty, Measurement Computing Corporation, and the Measurement Computing logo, are either trademarks or registered trademarks of Measurement Computing Corporation. SoftWIRE is a registered trademark of SoftWIRE Technology, Inc. Windows, Microsoft, and Visual Studio are either trademarks or registered trademarks of Microsoft Corporation. LabVIEW is a trademar
Inhaltszusammenfassung zur Seite Nr. 5
Table of Contents About this User's Guide....................................................................................................................... v What you will learn from this user's guide .........................................................................................................v Conventions in this user's guide..........................................................................................................................v Where to find more inform
Inhaltszusammenfassung zur Seite Nr. 6
Preface About this User's Guide What you will learn from this user's guide This user's guide explains how to install, configure, and use the PMD-1024HLS so that you get the most out of its USB digital I/O features. This user's guide also refers you to related documents available on our web site, and to technical support resources that can also help you get the most out of your PMD-1024HLS. Conventions in this user's guide For more information on … Text presented in a box signifies ad
Inhaltszusammenfassung zur Seite Nr. 7
Chapter 1 Introducing the PMD-1024HLS This user's guide contains all of the information you need to connect the PMD-1024HLS to your computer and to the signals you want to measure. The PMD-1024HLS is part of the Personal Measurement Device brand of USB-based data acquisition products. nd The PMD-1024HLS is a USB 2.0 low-speed module supported under Microsoft® Windows® 98 (2 edition), Windows ME, Windows 2000, and Window XP. It is designed for USB 1.1 ports, and was tested for full compa
Inhaltszusammenfassung zur Seite Nr. 8
PMD-1024HLS User's Guide Introducing the PMD-1024HLS PMD-1024HLS block diagram PMD-1024HLS functions are illustrated in the block diagram shown here. USB 2.0 compliant interface 32-bit USB event counter Microcontroller 1 channel 8 1 8 8 8 Di Dis sc cre rete te, lo , low- w- Port C Port C Port A Port B po pow we er r d dr ri iv ver ers s HI LO 8 8 4 4 Screw terminal I/O connector Figure 1-2. PMD-1024HLS functional block diagram Software features The following software ships with the PMD
Inhaltszusammenfassung zur Seite Nr. 9
PMD-1024HLS User's Guide Introducing the PMD-1024HLS Connecting a PMD-1024HLS to your computer is easy Installing a data acquisition device has never been easier. The PMD-1024HLS relies upon the Microsoft Human Interface Device (HID) class drivers. The HID class drivers ship with every copy of Windows that is designed to work with USB ports. We use the Microsoft HID because it is a standard, and its performance delivers full control and maximizes data transfer rates for your PMD-1024HLS.
Inhaltszusammenfassung zur Seite Nr. 10
Chapter 2 Installing the PMD-1024HLS What comes with your PMD-1024HLS shipment? As you unpack your PMD-1024HLS, make sure that the following components are included. Hardware PMD-1024HLS USB cable (2 meter length) Software The Measurement Computing Data Acquisition Software CD contains the following software: InstaCal installation, calibration, and test utility TracerDAQ suite of virtual instruments SoftWIRE for VS .NET SoftWIRE MCC DAQ Components for .NET 2-1
Inhaltszusammenfassung zur Seite Nr. 11
PMD-1024HLS User's Guide Installing the PMD-1024HLS Documentation In addition to this hardware user's guide, you should also receive the DAQ Software Quick Start (available in PDF at www.mccdaq.com/PDFmanuals/DAQ-Software-Quick-Start.pdf). Read this booklet completely before installing any software and hardware. Unpacking the PMD-1024HLS As with any electronic device, you should take care while handling to avoid damage from static electricity. Before removing the PMD-1024HLS from its pa
Inhaltszusammenfassung zur Seite Nr. 12
PMD-1024HLS User's Guide Installing the PMD-1024HLS When you connect the PMD-1024HLS for the first time, a Found New Hardware popup balloon (Windows XP) or dialog (other Windows versions) appear as the PMD-1024HLS is detected. Another Found New Hardware balloon or dialog opens that identifies the PMD-1024HLS as a USB Human Interface Device. When the balloon or dialog closes, the LED on the PMD-1024HLS should flash and then remain lit. This indicates that communication is established b
Inhaltszusammenfassung zur Seite Nr. 13
Chapter 3 Functional Details External components The PMD-1024HLS has the following external components, as shown in Figure 3-1. USB connector LED Screw terminal banks (2) Screw terminal pins 1 to 20 LED Screw terminal USB pins 21 to 40 connector/cable Figure 3-1. PMD-1024HLS external components USB connector The USB connector is on the right side of the PMD-1024HLS housing. This connector provides +5 V power and communication. The voltage output is system-dependent, and
Inhaltszusammenfassung zur Seite Nr. 14
PMD-1024HLS User's Guide Functional Details Screw terminal wiring The PMD-1024HLS has two rows of screw terminals—one row on the top edge of the housing, and one row on the bottom edge. Each row has 20 connections. Pin numbers are identified here. Figure 3-2. PMD-1024HLS screw terminal pin numbers Screw terminal – pins 1-20 The screw terminals on the top edge of the PMD-1024HLS (pins 1 to 20) provide the following connections: Eight digital I/O connections (Port C0 to Port C7) One c
Inhaltszusammenfassung zur Seite Nr. 15
PMD-1024HLS User's Guide Functional Details Digital I/O terminals (Port A0 to A7, Port B0 to B7, Port C0 to C7) Connect up to 24 digital I/O lines to the screw terminal containing pins 1 to 8 (Port C0 to Port C7), pins 21 to 28 (Port A0 to Port A7), and pins 32 to 39, (Port B0 to Port B7). Refer to the pinout diagram on page 3-2 for the location of these pins. You can configure each digital port for either input or output. When configured for input, you can use the PMD-1024HLS digital I
Inhaltszusammenfassung zur Seite Nr. 16
PMD-1024HLS User's Guide Functional Details Port A0 +GND +5 V Figure 3-4. Schematic showing switch detection by digital channel Port A0 For more information on digital signal connections For more information on digital signal connections and digital I/O techniques, refer to the Guide to Signal Connections (available on our web site at www.mccdaq.com/signals/signals.pdf). Power terminals The USB +5 V connection (pin 30) is on the bottom screw terminal of the PMD-1024HLS. Refer to the pin
Inhaltszusammenfassung zur Seite Nr. 17
PMD-1024HLS User's Guide Functional Details If you want to sink the maximum of 64 mA per DIO line, you can only do so with up to six lines (440 mA ÷ 64 mA/line = 6.8 ≈ 6 lines). To sink current with all 24 DIO outputs at any one time, you can sink a maximum of 18 mA per line. Ground terminals The nine ground (GND) connections are identical, and provide a common ground for all PMD-1024HLS functions. Refer to the pinout diagram on page 3-2 for the location of the GND terminal. Counter termi
Inhaltszusammenfassung zur Seite Nr. 18
PMD-1024HLS User's Guide Functional Details To configure a pull-down connection for a specific port, wire the pull-up/pull-down terminal to a GND terminal. Figure 3-6. Pull-down connection for Port A Wiring schematics are shown here for each pull-up/pull-down terminal. Dotted lines represent a pull- up or pull-down connection. USB +5 V DIO 0 (Port A0) Pull-up DIO 1 (Port A1) Pin 15 DIO 2 (Port A2) DIO 3 (Port A3) Port A DIO 4 (Port A4) DIO 5 (Port A5) DIO 6 (Port A6) Pull-down
Inhaltszusammenfassung zur Seite Nr. 19
Chapter 4 Specifications Typical for 25 °C unless otherwise specified. Specifications in italic text are guaranteed by design. Digital input/output Table 4-1. Digital I/O specifications Digital input type 74ACT373 Digital output type 74FCT244 Number of I/O 24 (port A0 through port C7) Configuration 2 banks of 8 and 2 banks of 4 or 3 banks of 8 Pull up/pull-down configuration Internal 47K resistors may be user configured for pull-up or pull-down via external connection of "Port x P
Inhaltszusammenfassung zur Seite Nr. 20
PMD-1024HLS User's Guide Specifications Counter section Table 4-2. Counter specifications Pin name (Note 4) CTR Counter type Event counter Number of channels 1 Input source CTR screw terminal Resolution 32 bits Schmidt trigger hysteresis 20 mV to 100 mV Input leakage current ±1 µA Maximum input frequency 1 MHz High pulse width 500 ns min Low pulse width 500 ns min Input low voltage 0 V min, 1.0 V max Input high voltage 4.0 V min, 15.0 V max Note 4: CTR is a Schmitt trigger in