Inhaltszusammenfassung zur Seite Nr. 1
OWNERS MANUAL
CONVECTION PROPANE CONSTRUCTION HEATERS
Model
100R-NG
QUESTIONS?
MISSING / DAMAGED PARTS
Please do not return this product to the store.
If a part is damaged or missing, simply e-mail us at
php@allpro-heaters.com, or visit our website at
http://allpro-heaters.com, or call our Customer
STOP
Service Department at (888) 619-7060.
We will be happy to assist you!
You can register your heater on line at
http://allpro-heaters.com/warranty.
TABLE OF CONTENTS
HEATER SPECIFICATIONS.........
Inhaltszusammenfassung zur Seite Nr. 2
Model 100R-NG HEATER SPECIFICATIONS Type of Gas: For use with NATURAL GAS ONLY Gas Supply Pressure to regulator Maximum: 1/2 psi Minimum: 5" W.C. regulator out 4" W.C. Ignition: Manual, piezo igntion Model: 100R-NG Rating: 100,000 BTU/hr Fuel Consumption: 100 cu. ft./hr Fuel Orifice Port No.: 18 Fuel Orifice Port Size: #55 Drill WARNINGS Y
Inhaltszusammenfassung zur Seite Nr. 3
Model 100R-NG SAFETY PRECAUTIONS OPERATING PRECAUTIONS This is a natural gas, direct-fired, radiant heater. It's intended use is primarily temporary heating of buildings under 1.Check the heater thoroughly for damage. DO NOT operate a construction, alteration or repair. damaged heater. 2.DO NOT modify the heater or operate a heater which has When the heater is to be operated in the presence of other been modified from its original condition. people the user is responsible for properly acquaintin
Inhaltszusammenfassung zur Seite Nr. 4
Model 100R-NG ODOR FADE WARNING WARNING heater dataplate, or contact the Scheu Products Company to determine combustion air ventilation requirements of the Asphyxiation Hazard heater. • Do not use this heater for heating human living quarters. • Lack of proper ventilation air will lead to improper • Do not use in unventilated areas. combustion. • The flow of combustion and ventilation air must not be • Improper combustion can lead to carbon monoxide obstructed. poisoning leading to serious injur
Inhaltszusammenfassung zur Seite Nr. 5
MODEL 100-RANG OPERATING INSTRUCTIONS SERVICING PREPARING FOR OPERATION A hazardous condition may result if a heater is used that has 1.Check the heater for possible shipping damage. If any is been modified or is not functiong properly. When the heater is found, immediately notify your dealer. working properly: 2.Follow all of the "Safety Precautions". *The flame is contained within the heater. 3.Install plumbing to a low pressure (1/2 psig Maximum) *The flame is essentially blue with perhaps
Inhaltszusammenfassung zur Seite Nr. 6
100RNG PARTS Item No. Description Qty. Item No. Description Qty. 16 3101 Louvered Emitter 1 1 0814 Base Assembly 1 17 3102 Pan Hood 1 2 3095 Ballast 1 18 6500 Fitting, 1/2" x Close Nipple 1 3 1074 Valve Shield Assembly 1 19 6259 Regulator, 4" W.C. 1 4 6113 Orifice, #55 Drill 1 20 6125 Fitting, Male Connector 1 5 1510 Pilot Assembly 1 21 7253 Orifice Pilot 1 6 1072 Manifold Assembly 1 22 6384 Label, Natural Gas Only 1 7 7616 Thermoe
Inhaltszusammenfassung zur Seite Nr. 7
Model 100RNG or usage of trade. This warranty will not apply to any product WARRANTY which has been repaired or altered outside of the California We are pleased that you have selected our product and take factory in any respect which in our judgment affects its condition this opportunity to assure you that qualified service facilities are or operation. available if required. With the cooperation of independent dealers, a nationwide network of authorized servicing dealers is Some states do not al
Inhaltszusammenfassung zur Seite Nr. 8
Hand print only. Use black or blue ink pen to fill in this form. Cross or check inside the circle. Warranty Registration Your Information First Name Last name Mailing Address - City State Postal code E-mail Address <$9,999 $10,000 to $19,999 >$50,000 Annual house hold income before tax $20,000 to $34,999 $20,000 to $34,999 Age of Purchaser <20 years 20-29 years 30-39 years 40-49 years 50-59 years >60 years Fold Here Your Preferences In choosing your heater the following categories were: Male Wh
Inhaltszusammenfassung zur Seite Nr. 9
SCHEU PRODUCTS COMPANY, INC ATTN: MARKETING DEPARTMENT 8855 BAKER AVENUE RANCHO CUCAMONGA, CA 91730 Visit our website for product information, technical support, customer service, and warranty registration at: WWW.ALLPRO-HEATERS.COM for All-Pro products or WWW.UNVERISAL-HEATERS.COM for Universal products. Page -10-