Inhaltszusammenfassung zur Seite Nr. 1
Models
SG-TTW-09ESE-26
SG-TTW-09HC-26
SG-TTW-12HC-26
SG-TTW-12ESEZ-26
Electronic Through the Wall Air Conditioner
Operating Instructions
Inhaltszusammenfassung zur Seite Nr. 2
Contents IMPORTANT NOTE TO THE OWNER ........................... 1 IMPORTANT NOTE TO THE SERVICER ....................... 1 Unit Features ................................................................ 1 Transportation Damage .............................................. 1 Unpacking The Unit ..................................................... 1 Operating Instructions ................................................. 1 Installation Instructions ..............................................
Inhaltszusammenfassung zur Seite Nr. 3
Specifications • Noise level is measured at a distance of 3.28ft away from the front of the unit in cooling mode. • Power consumption is measured when the fan runs at the highest speed settings. • These specifications are for reference only. For actual data, please refer to the rating label on the unit. Model Number SG-TTW-09ESE-26 SG-TTW-09HC-26 SG-TTW-12ESEZ-26 SG-TTW-12HC-26 Power Supply (Ph/V/Hz) 1/115/60 1/230-208/60 1/115/60 1/230-208/60 Dehumidifying Capacity (Pt/Day) 60 60 81.6 8
Inhaltszusammenfassung zur Seite Nr. 4
Operating Instructions IMPORTANT NOTE TO THE OWNER This equipment is to be serviced by professionally trained Check the data specification plate and ensure the proper personnel only. If this equipment is improperly installed, voltage and current rating for the type of power plug on the adjusted or altered by an unqualified person, a safety unit is available. DO NOT REMOVE THE GROUNDING hazard may result. PRONG FROM THE POWER CORD. See Figure 1 for the types of acceptable plugs. Do not us
Inhaltszusammenfassung zur Seite Nr. 5
CHASSIS INSTALLATION WARNING 1. Remove front grille. See Figure A. To prevent electrical shock, property damage, personal injury, or death, do not remove grounding prong from plug. Follow Lift up on all operating instructions. Filter Handle Installation Instructions To ensure that the unit operates safely and efficiently, it must be installed, operated, and maintained according to these installation and operating instructions and all local codes and ordinances, or, in their absence, wi
Inhaltszusammenfassung zur Seite Nr. 6
Locking Plate Figure 3 3. Remove shipping pads inside air conditioner next to Figure C compressor. (See Figure B.) 6. If outlet is on the left side of the unit. route power cord as shown in Figure D. Remove Power shipping Cord pads Clamp Figure B 4. Carefully slide the chassis into the sleeve. Ensure Figure D that the ground wire is not pinched or in the path of the condenser fan. 5. Loosen locking plate screw and rotate tab with tab behind wall case flange (See Figure C) then tighte
Inhaltszusammenfassung zur Seite Nr. 7
To replace front grille: Grille Tab EXHAUST AIR VENT Figure 4 AIR DIRECTION: Horizontal louvers on the front grille let you control the air Hook the tabs on the front grille even with the tabs on the direction up and down. case and snap into place. Replace the screws and filter. Refer to Page 4, Figure A. VENT CONTROL AND AIR DIRECTION (See Figure E) The vent control is located behind the front grille on the right side of the air discharge area. When set at CLOSE only the air inside
Inhaltszusammenfassung zur Seite Nr. 8
Remove the front grille to adjust the vertical louvers side-to- Wiring side to direct the air left or right. Before wiring the unit, please review the following warnings and cautions. WARNING To avoid the risk of electrical shock, personal injury or death, do not service this unit without first opening all disconnects and/or removing the unit cord set plug from the wall outlet. WARNING To avoid the risk of electrical shock, personal injury, or property damage, do not use an extension cor
Inhaltszusammenfassung zur Seite Nr. 9
Air Conditioner ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin, thoroughly familiarize yourself with the control panel and Features remote as shown below and all its functions. Then follow the symbol for the functions you desire. The unit can be controlled by the touch pad alone or with the remote. LOWERS TEMPERATURE DISPLAYS TEMPERATURE/TIME OR TIME RAISES TEMPERATURE OR TIME TURNS UNIT SETS FAN SPEED ON OR OFF SETS MODE TIMER SLEEP MODE LOWERS TEMPERATURE DIS
Inhaltszusammenfassung zur Seite Nr. 10
OPERATING THE REMOTE CONTROL NOTE: Make sure there are no obstructions between the receiver on the A/C and the remote control. Do not drop or throw the remote control. Do not allow water to get inside the remote control and do not place the remote control in direct sunlight or a place where it is very hot. • Press the SLEEP button to turn SLEEP mode on or off. SLEEP mode is set to off automatically. When SLEEP mode is selected the timer can be adjusted. SLEEP mode is not available in
Inhaltszusammenfassung zur Seite Nr. 11
OPERATING THE REMOTE CONTROL • Press the TIMER button when the unit is off to set up the Auto-on timer. The Auto-on time can be set between .5 - 24 hours. The icons “T-ON” and “H” will flash for 5 seconds. Start select- ing the time using the “+” and “-” but- tons before the icons stop flashing. The time will increase/decrease in .5 hour increments with each press of the “+” or “-” buttons. To cancel the Auto-on time, manually press the ON/ OFF button to turn the unit on. • Press
Inhaltszusammenfassung zur Seite Nr. 12
Air Conditioner Features Guide for operation- General operation 1. To power on the unit, press the ON/OFF button. The unit will start to run. (Note: When it is powered off, the louvers will close automatically.) 2. Press MODE button, select desired running mode, or press COOL or HEAT mode to enter into the corresponding operation directly. 3. Press the + or - button to set the desired temperature. (It is unnecessary to set the temp. in AUTO mode.) 4. Press the FAN button to set fan speed.
Inhaltszusammenfassung zur Seite Nr. 13
Air Conditioner Features (continued) TO TURN UNIT ON: YOU WILL SEE: DO THIS: PRESS ON/OFF BUTTON TO CHANGE YOU WILL SEE: TEMPERATURE SETTING: DO THIS: PRESS TO RAISE PRESS TO LOWER Note: Tap or hold either up(^) or down(v) button until the desired temperature is seen on display. This temperature will be ° automatically maintained anywhere between 61F (16 ° C) and 86F (30 C) for both cooling and heating modes. If you want the display to read the actual room temperature, select the Fan Only
Inhaltszusammenfassung zur Seite Nr. 14
Air Conditioner Features (continued) : T O OPERAT E O N FA N ONLY: YOU WILL SEE LIGHT ON DO THIS: PRESS MODE BUTTON CHOOSE FAN ONLY Note: Use this function only when cooling is not desired but room air circulation is needed. You can choose any fan speed you prefer, EXCEPT AUTO FAN. During this function, the display will show the current room temperature, not the set temperature. TO USE THE : LIGHT ON YOU WILL SEE ENERGY SAVER FEATURE: DO THIS: PRESS MODE BUTTON CHOOSE ENERGY SAVER Note: I
Inhaltszusammenfassung zur Seite Nr. 15
Air Conditioner Features (continued) HEATING FEATURE (on some models): YOU WILL SEE: DO THIS: PRESS MODE BUTTON SELECT HEAT Note: This feature can be used with any combination of FAN Speeds, Timer, or Sleep Modes. When in the “Heat” Mode, the fan will run continuously while heat is needed. The temperature will automatically be maintained anywhere between 61°F (16°C) and 86°F (30°C). When the set room temperature is reached, the fan will cycle off and on to circulate and sample the room air.
Inhaltszusammenfassung zur Seite Nr. 16
ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure, here are more features in your control that you should know. � The Remote Control will operate all the control panel features, follow the same instructions. � The "Cool "circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit ! ! breaker tripping. The fan will continue to run during this time. � The co
Inhaltszusammenfassung zur Seite Nr. 17
WARRANTY One Year Limited Warranty Soleus International, Inc. warrants the accompanying Soleus Air Powered by Gree Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus International will, at its option, either repair or replace it, free of charge within a reasonable tim