Inhaltszusammenfassung zur Seite Nr. 1
Please read Owner’s Manual carefully
before operating the unit.
Inhaltszusammenfassung zur Seite Nr. 2
Main technical parameter of RT-135 Capability Unit Value Operating Cooling Capacity Btu/h 13500 Capabilities: Watts W 1220 Cooling Rated Full Load Current A 11.2 Operating Heating Capacity Btu/h 14400 capabilities: Watts W 1620 Heating Rated Full Load Current A 14.8 Air Flow Volume CFM 412/235 Power Supply 115VAC/60HZ/1Phase Operational Range-Cooling F 61 to 115 Operational Range-Heating F 17 to 90 Noise Inside The Room dB(A) 51 Level Outside The Room dB(A) 62 Refrigerant
Inhaltszusammenfassung zur Seite Nr. 3
Use RT-135 series air-condition have the capability of cooling / heating / ventilation and dehumidification and contain the character of resisting shake attrition and high-dependability. It can be used for applications such as RV units, trucks & vans, small-scale shipping vehicles & farm equipment. Structure and character Structure This air conditioning is in the top of structure Main components include evaporator, condenser, compressor, throttling device, air blower system, prote
Inhaltszusammenfassung zur Seite Nr. 4
Remote device Operation through the control panel or remote device Through the control panel in the room, user can control all functions of the air-conditioner. The parts of control contain the following functions: 1. Switch The air-conditioner can be started or stopped by the button “ON/OFF”. The indicator lamp “POWER” in the upper left corner is lighted when air-conditioner is running. 2. Choose button “MODE” This button confirms the working status of the air-conditioner.
Inhaltszusammenfassung zur Seite Nr. 5
The scheme of refrigeration system CONDENSER EVAPORATOR FAN COMPRESSOR THROTTLE 4
Inhaltszusammenfassung zur Seite Nr. 6
Schematic circuit diagram FU2 +5V GND A B com on C G DAT CLK REC KEY WAT1 WAT2 SENSOR1 SENSOR2 FU3 5 PT OPERATE PANEL TRANS-OUT 12AWG HEAT CONTROL PANEL T TRANS-IN 4 L-FAN H-FAN N N NN L L 12AWG L 110VAC N 60HZ PE 20AWG PE HEATER KA1 C1 1 BL RE RE KA1 R 2 YE BL GR WH MF CMCS C2 YE ~ ~ YE 3 WH + + GR GR FAN COMP
Inhaltszusammenfassung zur Seite Nr. 7
Cautions 1. In any case the compressor will restart 3 minutes after power failure 2. The air-conditioner adopts three core plugs: Modification will void warranty 3. Working voltage of the air-conditioner must keep within the range of 115VAC ±10. If the voltage is too high or low will lead to damage of the compressor. 4. The normal working environment temperature of the air conditioner is: 0F to115F Maintenance and Safeguard It will keep at maximum performance ratings if you per
Inhaltszusammenfassung zur Seite Nr. 8
No heat 1. Power is off. Check the circuit 2. Set temperature is in Adjust the set value improper position 3. Connector has fallen off. Tighten the plug. 4. Heater is defective Change the heater. 5. Fuse is open. Change the fuse. 6. Control panel is not Change the circuit panel. working. The fan doesn’t operate 1. Control panel is faulty. Change the panel. 2. The capacitor of fan Change the capacitor. defective. 3. Fan defective. Change the fan. Unusual sound or heavy 1. Installati
Inhaltszusammenfassung zur Seite Nr. 9
3. You must make mounting hole on indoor installation frame align with the hole on the top of the air-conditioner and tightly connect with 4-M10 special screw. 4. Install canvas-pipe You must make the flange of the canvas-pipe align with air outlet of the top of air-conditioner and connect them with screw, gasket, spring gasket and nut. 8
Inhaltszusammenfassung zur Seite Nr. 10
5. Prepare installing of indoor equip: Disassemble the indoor equip. 6. Install the indoor unit a) You must install the main of indoor tunnel and installation frame with four ST4.2X16 screw. Caution: It can be rotated from +90 °to -90 °. b) Installing the canvas pipe underparts You must put into metal flange from canvas pipe under part and tightly nip main vent-pipe and connect with ST4.2X16 screw. The surplus part is cut out. c) Install covers board of
Inhaltszusammenfassung zur Seite Nr. 11
Check 1. Check the complete installing manual to make sure unit is installed correctly and safe 2. Switch on the power, operate the air conditioner according to above methods. If it runs improperly, for example abnormal noise, running current too high or no temperature, please check owner’s manual. 10
Inhaltszusammenfassung zur Seite Nr. 12
3. Clean up the installing rubbish and restore decoration to original decor. 11
Inhaltszusammenfassung zur Seite Nr. 13
Warranty LIMITED WARRANTY Soleus International Inc. warrants the accompanying Soleus Air RT-135 Roof Top Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for the period of labor and parts specified below. PARTS 5 YEARS FOR COMPRESSOR 1 YEAR FOR OTHER COMPONENTS This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine maintenance. This warranty does not app