Inhaltszusammenfassung zur Seite Nr. 1
Intel® Server Chassis SR1450
User Guide
Order Number: C95452-002
Inhaltszusammenfassung zur Seite Nr. 2
Disclaimer ® Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a parti
Inhaltszusammenfassung zur Seite Nr. 3
Preface About this Manual Thank you for purchasing and using the Intel® Server Chassis SR1450. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server chassis. This document provides a brief overview of the features of the board/chassis, a list of accessories or other components you may need, troubleshooting information, and instructions on how to add and replace components on the Intel Server Chassis SR1450. For the
Inhaltszusammenfassung zur Seite Nr. 4
Preface Product Contents, Order Options, and Accessories The server chassis SR1450 is compatible with the Intel® Server Board SE7520JR2. Your Server Chassis SR1450 ships with the following items: A box of hardware components, referred to below as the “hardware box” One 520W power supply module, installed in the chassis Power distribution board, installed in the chassis Low-profile PCI-X riser, installed in the chassis CD-ROM / DVD drive tray, installed in the chassis System f
Inhaltszusammenfassung zur Seite Nr. 5
Preface You must choose from several required options when purchasing this chassis: Riser option, choose one: • Full-height PCI-X riser • Full-height PCI-Express* riser Hard drive installation option kit, choose one: • SCSI hot-swap backplane kit • SATA hot-swap backplane kit Control panel, choose one: • Standard control panel ® 2 • Intel Local Control Panel Rack option, choose one: • Tool-less rail kit (Optional Cable Management Arm (CMA) Accessory also available) • Rack brack
Inhaltszusammenfassung zur Seite Nr. 6
Preface Additional Information and Software If you need more information about this product or information about the accessories that can be used with this server board, use the following resources. These sources are available at http://support.intel.com/support/motherboards/server/chassis/SR1450/ Unless otherwise indicated in the table below, once on this Web page, type the document or software name in the search field at the left side of the screen and select the option to search “This
Inhaltszusammenfassung zur Seite Nr. 7
Preface Safety Information WARNING Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory
Inhaltszusammenfassung zur Seite Nr. 8
Preface Warnings System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components. Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications
Inhaltszusammenfassung zur Seite Nr. 9
Preface Safety Cautions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information or at http://support.intel.com/support/motherboards/server/sb/CS-010770.htm Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel- Serverplatinen u
Inhaltszusammenfassung zur Seite Nr. 10
Contents Warnings .......................................................................................................viii 1 Server Chassis Features ............................................................................. 14 Component Identification ......................................................................................................17 Internal Components....................................................................................................17 Stand
Inhaltszusammenfassung zur Seite Nr. 11
Contents Installing a PCI Add-in Card.........................................................................................47 Removing a PCI Add-in Card.......................................................................................49 Replacing the Standard Control Panel..................................................................................50 ® Replacing the Intel Local Control Panel...............................................................................51 Replac
Inhaltszusammenfassung zur Seite Nr. 12
Contents Extent of Limited Warranty....................................................................................................85 Warranty Limitations and Exclusions ....................................................................................86 Limitations of Liability ...................................................................................................86 How to Obtain Warranty Service..............................................................................
Inhaltszusammenfassung zur Seite Nr. 13
Contents Figure 41. Removing the Power Supply Air Duct.......................................................................56 Figure 42. Removing a Power Supply Fan Module ...................................................................57 Figure 43. Removing the Power Distribution Board...................................................................59 Figure 44. Installing the Power Distribution Board.....................................................................60 Figure
Inhaltszusammenfassung zur Seite Nr. 14
1 Server Chassis Features ® This chapter briefly describes the main features of Intel Server Chassis SR1450. This chapter provides drawings of the product, a list of the server features, and diagrams showing the location of important components and connections on the server chassis. The Intel Server Chassis SR1450 is shown in the following drawing. TP01584 ® Figure 1. Intel Server Chassis SR1450 ® Intel Server Chassis SR1450 User Guide 14
Inhaltszusammenfassung zur Seite Nr. 15
Server Chassis Features 4 Table 1 summarizes the major features of the server chassis. Table 1. Server Chassis Features Feature Description 1.703 inches high Dimensions 16.930 inches wide 27.480 inches deep (including power receptacles) 35 pounds (max chassis weight) Hard Drives (dependent Up to three hot-swap SATA or hot-swap SCSI drives on option selected) Slimline bay for CD-ROM, DVD-ROM drive, or slimline floppy drive Peripherals (dependent on option selected) Kit to
Inhaltszusammenfassung zur Seite Nr. 16
Server Chassis Features Table 1. Server Chassis Features (continued) Power Supply One hot-swap 520W power supply module One plus one hot-swap redundant 520W power supply (optional accessory) Lockable front bezel (optional accessory) System Security Chassis intrusion switch Lock attach point for Kensington* style lock Fans • Four 40x40x56mm dual-rotor system fans • One 40x40x28mm single rotor system fan • Two 40x40x56mm dual-rotor power supply fans (dedicated to power supply coo
Inhaltszusammenfassung zur Seite Nr. 17
Server Chassis Features Component Identification Internal Components The diagram below shows the server chassis with a server board installed into it. D E C B A F M G H L K I J TP01585 A. Single system PCI fan H. System fan module B. Power supply fan modules I. SATA or SCSI backplane C. Power supply air duct J. Control panel (Standard Control Panel shown) D. Rear power supply module K. Drive bay area (drives not included) E. PCI Riser assembly L. CD/DVD – ROM/Floppy drive bay F. Serve
Inhaltszusammenfassung zur Seite Nr. 18
Server Chassis Features Standard Control Panel The diagram below shows the features available on the Standard Control Panel. The Standard Control Panel is one of two required front panel options that can be selected. The other option is the Intel® Local Control Panel. For instructions on installing the Standard Control Panel, see “Replacing the Standard Control Panel.” A B C D E F G H I J K TP01586 Callout Feature Function A USB 2.0 port Allows you to attach a USB component to the fro
Inhaltszusammenfassung zur Seite Nr. 19
Server Chassis Features ® Intel Local Control Panel ® The diagram below shows the features available on the Intel Local Control Panel. The Intel Local Control Panel is one of two required front panel options that can be selected. The other option is the Standard Control Panel. For instructions on installing the Standard Control Panel, see “Replacing the Intel® Local Control Panel”. ✏ NOTE ® This control panel requires the installation of the Intel Management Module, Professional or Advan
Inhaltszusammenfassung zur Seite Nr. 20
Server Chassis Features Callout Feature Function J System Status LED Solid green indicates normal operation. Blinking green indicates degraded performance. Solid amber indicates a critical or non-recoverable condition. Blinking amber indicates a non-critical condition. No light indicates POST is running or the system is off. K NIC 2 activity LED Continuous green light indicates a link between the system and the network to which it is connected. L NIC 1 activity LED Blinking green light