Inhaltszusammenfassung zur Seite Nr. 1
Inhaltszusammenfassung zur Seite Nr. 2
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 1:1 Inverter 185 H Standard PAC SPW CR 184 GVH56B PIPING SUCTION 1/2" LIQUID 1/4" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 20 g/m MAXIMUM PIPING LENGTH 40m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY 16a Single Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 WIRING
Inhaltszusammenfassung zur Seite Nr. 3
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 1:1 Inverter 255 H Standard PAC SPW CR 254 GVH56B / GVH8B PIPING SUCTION 5/8" LIQUID 3/8" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 40 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56B 20a Single Phase - GVH8B 10a Three Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75
Inhaltszusammenfassung zur Seite Nr. 4
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 1:1 Inverter 365 H Standard PAC SPW CR 364 GVH56B / GVH8B PIPING SUCTION 5/8" LIQUID 3/8" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 40 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56B 25a Single Phase - GVH8B 10a Three Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75
Inhaltszusammenfassung zur Seite Nr. 5
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 1:1 Inverter 485 H Standard PAC SPW CR 484 GVH56B / GVH8B PIPING SUCTION 5/8" LIQUID 3/8" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 40 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56B 32a Single Phase - GVH8B 16a Three Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75
Inhaltszusammenfassung zur Seite Nr. 6
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 1:1 Inverter 605 H Standard PAC SPW CR 604 GVH56B / GVH8B PIPING SUCTION 5/8" LIQUID 3/8" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 40 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56B 40a Single Phase - GVH8B 16a Three Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75
Inhaltszusammenfassung zur Seite Nr. 7
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 2:1 Inverter 125 H Standard PAC SPW CR 484 GVH56B / GVH8B PIPING SUCTION 5/8" to joint 1/2" from joint to indoor LIQUID 3/8" to joint 1/4" from joint to indoor GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 3/8" = 40 g/m & 1/4" = 20 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56
Inhaltszusammenfassung zur Seite Nr. 8
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 2:1 Inverter 255 H Standard PAC SPW CR 484 GVH56B / GVH8B PIPING SUCTION 5/8" LIQUID 3/8" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 40 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56B 32a Single Phase - GVH8B 16a Three Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75
Inhaltszusammenfassung zur Seite Nr. 9
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 3:1 Inverter 165 H Standard PAC SPW CR 484 GVH56B / GVH8B PIPING SUCTION 5/8" to joint 1/2" from joint to indoor LIQUID 3/8" to joint 1/4" from joint to indoor GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 3/8" = 40 g/m & 1/4" = 20 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56
Inhaltszusammenfassung zur Seite Nr. 10
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 3:1 Inverter 185 H Standard PAC SPW CR 604 GVH56B / GVH8B PIPING SUCTION 5/8" to joint 1/2" from joint to indoor LIQUID 3/8" to joint 1/4" from joint to indoor GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 3/8" = 40 g/m & 1/4" = 20 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56
Inhaltszusammenfassung zur Seite Nr. 11
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 4:1 Inverter 125 H Standard PAC SPW CR 484 GVH56B / GVH8B PIPING SUCTION 5/8" to joint 1/2" from joint to indoor LIQUID 3/8" to joint 1/4" from joint to indoor GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 3/8" = 40 g/m & 1/4" = 20 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56
Inhaltszusammenfassung zur Seite Nr. 12
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 4:1 Inverter 165 H Standard PAC SPW CR 604 GVH56B / GVH8B PIPING SUCTION 5/8" to joint 1/2" from joint to indoor LIQUID 3/8" to joint 1/4" from joint to indoor GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 3/8" = 40 g/m & 1/4" = 20 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56