Inhaltszusammenfassung zur Seite Nr. 1
SECTION: 6.10.079
NOTICE TO INSTALLER: Instructions must remain with installation.
FM1613
0609
Supersedes
0409
Product information presented
here re fl ects con di tions at time
of publication. Consult factory
re gard ing dis crep an cies or
visit our web site:
in con sis ten cies. P.O. BOX 16347 • Louisville, KY 40256-0347
3649 Cane Run Road • Louisville, KY 40211-1961
www.zoeller.com
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
MODELS 580 & 585
BATTERY BACKUP PEDESTAL SUMP
Inhaltszusammenfassung zur Seite Nr. 2
Limited Warranty etc. in all pumping applications. The warranty set out in the paragraph Manufacturer warrants, to the purchaser and subsequent owner dur- above is in lieu of all other warranties expressed or implied; and we ing the warranty period, every new product to be free from defects do not authorize any representative or other person to assume for us in material and workmanship under normal use and service, when any other liability in connection with our products. properly used and
Inhaltszusammenfassung zur Seite Nr. 3
Ten Helpful Hints For Easy Installation 6. The battery & charger should be placed on a shelf. 1. Remove all debris from pit before installation. 7. Check fl oat On/Off levels per STEP 2 of instructions. 2. Use a deep cycle battery only. Refer to battery de scrip - tions on page 6. 8. Apply grease to the Positive and Negative terminals of the battery to prevent corrosion. 3. Be sure the pump is on a fi rm, level surface. 9. Check the battery water level once a m
Inhaltszusammenfassung zur Seite Nr. 4
STEP 1 Placement of the Pump in the Pit Note: If your pit has a cover, then it will have to be modifi ed to accept the ® Aquanot . ON/OFF SWITCH 1.1) Inspect the pit for debris and clean as nec es sary PUMP MOTOR 1.2) Place the pump in the pit making certain that it is on a stable level MAIN DISCHARGE surface. Refer to Figure 1.1. LINE IMPORTANT: If this pump is to be used as a backup to your primary pump, PRIMARY PUMP then make certain that there is no interference between the two pu
Inhaltszusammenfassung zur Seite Nr. 5
STEP 3 Installation of the Discharge Piping 3.1) Assemble the discharge pipe into the pump as shown in Figure 3.1. CHECK VALVE CHECK VALVE IMPORTANT: In order for this installation to work properly, a check valve MAIN MAIN DISCHARGE DISCHARGE must be installed onto the discharge line. LINE LINE PRIMARY PUMP PRIMARY PUMP P/N 30-0100 Recommend the following Zoeller check valves: P/N 30-0101 OR Some local codes require union check with ball valve. P/N 30-0102 } P/N 30-0103 SK1778 Figure 3.1
Inhaltszusammenfassung zur Seite Nr. 6
® Operation of the Aquanot Charger (Model 585 Only) The charger automatically monitors and charges your battery. In the event of a power outage the pump will be powered by the battery. Once line power is restored, the charger will recharge the battery. If there is a failure of the primary pump, the charger will supply power to the pump through the battery if line power is present; otherwise, the battery will take over until the problem has been corrected. The lights on the front panel of t
Inhaltszusammenfassung zur Seite Nr. 7
SK1786 Illustrated Parts Breakdown MOD ELS: REF. 580-A 580-B 580-C 580-D 580-E 585-A 585-B 585-C 585-D 585-E 585-F 585-G NO. DESCRIPTION QTY *Consult *Consult *Consult 1 Motor Brushes 2 011882 011882 011882 013878 011882 011882 011882 011882 013878 Factory Factory Factory 2 Pump Alarm 1 012485 012485 012485 012485 012485 012485 012485 012485 012485 012485 012485 012485 3 Pump Switch 1 011990 011990 017205 017205 017205 011990 011990 011990 017205 017205 017205 017205 4 Float Kit & Cable 1 012109
Inhaltszusammenfassung zur Seite Nr. 8
Troubleshooting Guide CONDITION POSSIBLE CAUSE REMEDY Low voltage, blown fuse open circuit. Have a qualifi ed electrician check fuse and cir cuit. Impeller bound. Replace fuse. A PUMP WILL NOT START OR RUN. Blown pump fuse. Defective Switch Contact factory. Motor or wiring shorted. B PUMP STARTS TOO SOON. Float “ON” point is adjusted too low. Refer to STEP 2. Float is obstructed. Inspect fl oat operation and correct problem. C PUMP WILL NOT SHUT OFF. Float “Off” point adjusted too low. Adjust “Off