Inhaltszusammenfassung zur Seite Nr. 1
C
N
E
R
G
T
I
Outdoor Gas Fireplace
Models:
ODGSR36A, ODGSR42A
INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any
Inhaltszusammenfassung zur Seite Nr. 2
ODGSR Series Outdoor Gas Fireplace Table of Contents Thank you and Congratulations on your purchase of a CFM Corporation fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions .............................................................
Inhaltszusammenfassung zur Seite Nr. 3
ODGSR Series Outdoor Gas Fireplace General Information This gas appliance should be installed by a qualified Enclosures for LP-Gas Supply Systems installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Enclosures for LP-gas supply cylinders shall be ventilated by openings at the level of the cylinder valve and at floor level. The Appliances and Equipment. effectiveness of the opening(s) for purposes of ventilation shall FOR U.S.A Instal
Inhaltszusammenfassung zur Seite Nr. 4
ODGSR Series Outdoor Gas Fireplace Fireplace Dimensions ��" (559mm) Rough Opening Depth 48 � � �" (1232mm) ���" (13mm) ����� " (572mm) 22" (559mm) ���" Recessed (16mm) Nailing Flange �����" (822mm) Rough Opening Width 41" (1041mm) Rough Opening Height ���" ����" (191mm) 39���" 43���" Low Voltage (1007mm) (1111mm) Wire Access �� " 36" Low Voltage (622mm) (914mm) Wire Access 14 ���" (362mm) 8 ���" 3 ���" (210mm) (95mm) 14 ���" 40" 3 ���" 3���" ����" (362mm) (1016mm) (95mm) (98mm) (165mm) Gas
Inhaltszusammenfassung zur Seite Nr. 5
ODGSR Series Outdoor Gas Fireplace Screened Porch Installation The ODGSR may be installed safely and is design certified by CSA to be installed in a screened porch with these guidelines: Minimum porch area ...............................96 sq. feet (9sq m) Minimum celing height ................................. 92" (2,337 mm) Minimum of two (2) walls must be screened J I H Minimum top of screen height, side walls ....6'6" (1,981 mm) G Minimum screen area .............................64 sq
Inhaltszusammenfassung zur Seite Nr. 6
ODGSR Series Outdoor Gas Fireplace Framing and Finishing Gas Specification Max. Min. Check appliance to make sure it is levelled Model Fuel Gas Control Input Input and properly positioned. ODGSR36ARN Nat. Millivolt Hi/Lo 60,000 42,600 ODGSR36ARP Prop. Millivolt Hi/Lo 60,000 44,000 The appliance should only be mounted on the following ODGSR42ARN Nat. Millivolt Hi/Lo 60,000 42,600 surfaces: ODGSR42ARP Prop. Millivolt Hi/Lo 60,000 44,000 • A flat combustible (burnable) surface. • A raised
Inhaltszusammenfassung zur Seite Nr. 7
ODGSR Series Outdoor Gas Fireplace The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa). If gas piping from the source to the appliance location has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size. The gas pipeline can be brought in through the right side of the appliance. A knockout is provid
Inhaltszusammenfassung zur Seite Nr. 8
TPTH TP TH ODGSR Series Outdoor Gas Fireplace NOTE: If glass doors are installed, the unit must be Remote Wall Switch operated with the doors fully open. (Fig. 10) If the NOTE: Use an approved outdoor switch. doors are not fully open, the thermodisk will auto- matically turn the unit off. 1. Thread wire through the low voltage wire access hole located on either side of unit. Do not cut wire or insu- CAUTION: After the unit cools, the burner lation on metal edges. Ensure that wire is protec
Inhaltszusammenfassung zur Seite Nr. 9
ODGSR Series Outdoor Gas Fireplace Operating Instructions Log Installation Right Cross Log 1. Remove logs from the packaging. Left Cross As with all plastic, these bags Log are not toys and should always be kept away from children and infants. 2. Place left rear log on rear log support. Right Rear Ensure that log is firmly positioned and Log there is no side-to-side movement. (Figs. 11 & 12) 3. Carefully place Ember Log between grate and burner. (Figs. 11 & 12) Left Rear 4. Place the
Inhaltszusammenfassung zur Seite Nr. 10
I L ODGSR Series Outdoor Gas Fireplace ELECTRONIC IGNITION Flame Adjustment 3/8"-1/2" For units equipped with Hi/Lo valves, flame adjustment is accomplished by rotating the Hi/Lo adjustment knob located near the center of the gas control. NOVA SIT Pilot Turn Turn clockwise counterclockwise to lower to increase FP581 flame height flame height Fig. 16 Proper pilot flame height. Fig. 13 Flame adjustment knob for SIT820 valve. FP581 Flame Characteristics FP390 NVB-PILOTS FLAME ADJUSTMENT KNOB
Inhaltszusammenfassung zur Seite Nr. 11
ODGSR Series Outdoor Gas Fireplace Optional Weather Enclosure Optional Stainless Steel Hood An optional weather enclosure is available to protect An optional stainless steel hood is available for both the the burner when not in use. ODGSR36A and ODGSR42A. CAUTION: Do not use the weather enclosure NOTE: The stainless steel hood may NOT if the unit has glass doors installed. be used when the optional glass doors are installed. Installation Instructions Installation Instructions: 1. Turn the
Inhaltszusammenfassung zur Seite Nr. 12
O 3 2 ON 1 T O ODGSR Series Outdoor Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- • If you cannot reach your gas supplier, call the ally. When lighting the pilot follow these Fire Department instructions exactly. C. Use only your hand to push in or turn
Inhaltszusammenfassung zur Seite Nr. 13
ODGSR Series Outdoor Gas Fireplace Troubleshooting Nova SIT 820 Standing Pilot START CHECK Gas Supply On Supply Line Hooked up NO Shutoff Valve Open YES Lockout has engaged. Wait 60 seconds and try again. Piezo not tight enough for good ground. Pilot Lights with For spark at electrode while NO Piezo Ignitor depressing Piezo (Red Button) 1/8" gap to pilot hood needed. All wiring connections Replace Piezo Ignitor Thermodisk YES For Air in the lines Thermopile needs a minimum 325mV.
Inhaltszusammenfassung zur Seite Nr. 14
ODGSR Series Outdoor Gas Fireplace Maintenance Burner and Burner Compartment Cleaning the Standing Pilot It is important to keep the burner and the burner Control System compartment clean. At least once per year the logs The burner and control system consists of: should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs • main burner as per the instructions in this manual. • gas orifice Always handle the logs with care as they are fragile • pilot burn
Inhaltszusammenfassung zur Seite Nr. 15
� � � � � � � � � � � � � � � � � � � THTP TP TH � � � � � � � � � � � � � � � � � ODGSR Series Outdoor Gas Fireplace 1. ODGSR42A Logs 1. ODGSR36A Logs 4a/b b a 2 b a d e c d 3 c h f g 25 11 12a/b 7 10 9 6 8 16 19a/b 13 22 20 15 14 21 17 7114 18a/b CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ODGSR36A, ODGSR42A Ref. Description ODGSR36A ODGSR42A 1. Logs - Complete Set 20007180 2
Inhaltszusammenfassung zur Seite Nr. 16
ODGSR Series Outdoor Gas Fireplace ODGSR36A, ODGSR42A (continued) Ref. Description ODGSR36A ODGSR42A 14. Pilot Tubing 10001296 10001296 15. Cable Ignitor 24" 7522432 7522432 16. Thermocouple 24" 7531137 7531137 17. Grate 20006819 20006819 18a. Pilot Orifice - Natural 10002268 10002268 18b. Pilot Orifice - LP 10002269 10002269 19a. Valve NOVA - Natural 7529141 7529141 19b. Valve NOVA - LP 7529142 7529142 20a. Air Shutter - Natural 20009120 20000129 21. Hearth Brick Cover 20007183 200071
Inhaltszusammenfassung zur Seite Nr. 17
ODGSR Series Outdoor Gas Fireplace Accessories The following accessories are available from your local Majestic Fireplaces distributor. Each accessory comes with a separate installation instruction for mounting to the particular firebox. Be sure to read each instruction thoroughly before installing. Accessory Description Model Number 4" Stainless Steel For heater up to 40,000 BTU's and mantels UV36SH4 Hood 8" high by 12" wide UV42SH4 Glass Doors Designed to enhance the look of the firepl
Inhaltszusammenfassung zur Seite Nr. 18
ODGSR Series Outdoor Gas Fireplace 18 20007114
Inhaltszusammenfassung zur Seite Nr. 19
ODGSR Series Outdoor Gas Fireplace LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY • If upon inspection, the damage is found to be the fault of the manufacturer, repairs will be authorized at no charge to the customer CFM Corporation (hereinafter referred to collectively as the Company) pa
Inhaltszusammenfassung zur Seite Nr. 20
CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com