INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
INSTALLATION AND
OPERATION INSTRUCTIONS
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.
GD82NT-T
NATURAL GAS
GD82PT-T
PROPANE
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
WARNING: If the information in these
instructions are not followed exactly, a fire
or explosion may result causing property
damage, persona
Inhaltszusammenfassung zur Seite Nr. 2
2 TABLE of CONTENTS TM PG 2-5 INTRODUCTION 19 NIGHT LIGHT REPLACEMENT Warranty Dimensions 19-23 OPERATION / MAINTENANCE General Instructions Time Out General Information Fireplace Operation Care of Glass & Plated Parts Hand Held Remote Operation Dip Switch Number Chart 5-9 VENTING Operating Instructions Vent lengths Venting Specifi cations Air Terminal Locations 24 ADJUSTMENTS Pilot Burner Adjustment 10-15 INSTALLATION/FRAMING Venturi
Inhaltszusammenfassung zur Seite Nr. 3
3 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete fi replace is thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the qual
Inhaltszusammenfassung zur Seite Nr. 4
4 FIGURE 1 58" 46" 3 17 /4" 5 37 /8" 4" DIA. 7" DIA. 1 22 /8" 21" 5" 7 13 /8" 2" 7 /8" 7 8 /8" 24" 14" 28" 28" Under extreme vent confi gurations, allow several minutes GENERAL INSTRUCTIONS (5-15) for the fl ame to stabilize after ignition. THIS GAS FIREPLACE SHOULD BE INSTALLED AND SER- Provide adequate ventilation and combustion air. VICED BY A QUALIFIED INSTALLER to conform with local Provide adequate accessibility clearance for servicing and codes. Installation practices vary from region
Inhaltszusammenfassung zur Seite Nr. 5
5 and fueled with natural gas. This fi replace may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited The inner stainless steel looking fi rebox back will discolour by local codes. with heat, turning a light brown, straw like colour that is to be This fi replace is only for use with the type of gas indicated considered normal. on the rating plate. This fi replace is not convertible for use with other gases, unless a certifi ed kit is used. CARE
Inhaltszusammenfassung zur Seite Nr. 6
6 DEFINITIONS ELBOW VENT LENGTH VALUES feet inches for the following symbols used in the venting calculations 1° 0.03 0.5 and examples are: 15° 0.45 6.0 > - greater than 30° 0.9 11.0 > - equal to or greater than 45° 1.35 16.0 < - less than 90°* 2.7 32.0 < - equal to or less than H - total of both horizontal vent lengths (H ) and offsets T R (H ) in feet O * the fi rst 90° offset has a zero value and is shown in the H - combined horizontal vent lengths in feet R formula as
Inhaltszusammenfassung zur Seite Nr. 7
7 TOP EXIT / HORIZONTAL TERMINATION V = V = 6 ft when (H ) > (V ) 1 T T T H = 3 ft 1 Simple venting confi guration (only one 90° elbow) H = 5 ft 2 H = H + H = 3 + 5 = 8 ft R 1 2 H = .03 (two 90° elbows - 90°) = .03(180° - 90°) = 2.7 FIGURE 6 O ft H = H + H = 8 + 2.7 = 10.7 ft T R O See graph to determine the required verti- H + V = 10.7 + 6 =16.7 T T cal rise V for the required horizontal run T Formula 1: H < 4.2 V H . T T T 4.2 V = 4.2 x 6 = 25.2 ft T 10.7 < 25.2 Formula 2: H
Inhaltszusammenfassung zur Seite Nr. 8
8 TOP EXIT VERTICAL TERMINATION REQUIRED VERTICAL when (H ) < (V ) T T RISE IN FEET See graph to V determine the T required vertical rise HORIZONTAL VENT RUN PLUS OFFSET IN V for the required T FEET H T horizontal run H . T The shaded area within the lines represents ac- ceptable values for H and V . T T For vent confi gurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply: Formula 1: H < V T T Formula 2: H + V < 40 feet T T
Inhaltszusammenfassung zur Seite Nr. 9
9 FIGURE 12 W415-0583 / B / 05.23.07
Inhaltszusammenfassung zur Seite Nr. 10
10 INSTALLATION WALL AND CEILING PROTECTION For optimum performance it is recommended that all horizontal runs have a minimum ¼ inch rise per foot using fl exible venting. For safe and proper operation of the fi replace, follow the venting instructions exactly. HORIZONTAL TERMINATION: A clearance to combustibles of 2" must be maintained during the fi rst 24” of venting when penetrating combustible walls. The fi restop spacer (W500-0292) supplied with the unit should be used to maintain this cl
Inhaltszusammenfassung zur Seite Nr. 11
11 USING FLEXIBLE VENT COMPONENTS Use only approved aluminum fl exible liner kits marked: VERTICAL AIR TERMINAL INSTALLATION 1. Move the fi replace into position. 2. Fasten the roof support to the a “Wolf Steel Approved Venting” as roof using the screws provided. identifi ed by the stamp only on the 7” The roof support is optional. In this case the venting is to be adequately outer liner. supported using either an alternate For safe and proper operation of the fi replace, follow the venting
Inhaltszusammenfassung zur Seite Nr. 12
12 FIREPLACE VENT CONNECTION 1. Install the 4” diameter aluminium fl exible liner to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using the high temperature sealant FIGURE 20 (W573-0007 not provided). 2. Install the 7” diameter aluminium fl exible liner to the fi replace. Attach and seal the joints. USING RIGID VENT COMPONENTS The vent system must be supported approximately every 3 EXTENDED HORIZONTAL AIR TERMINAL feet for both vertical and horizontal r
Inhaltszusammenfassung zur Seite Nr. 13
13 6. Remove nails from the shingles, above and to the sides GAS INSTALLATION of the chimney. Place the fl ashing over the air terminal and Proceed once the vent installation is complete. slide it underneath the sides and upper edge of the shingles. Ensure that the air terminal is properly centred within the fl ash- Note : All gas connections must be contained within ing, giving a 3/4” margin all around. Fasten to the roof. Do NOT the fi replace when complete. 1. The fi replace is designed to a
Inhaltszusammenfassung zur Seite Nr. 14
14 CLEARANCE TO COMBUSTIBLES FRAMING It is best to frame your fi replace after it is positioned and the MAINTAIN THESE MINIMUM CLEARANCES TO COM- vent system is installed. Use 2x4’s and frame to local build- BUSTIBLES: ing codes. Fireplace framing - 0” to stand-offs (top, rear & sides) Note: In order to avoid the possibility of exposed insulation Fireplace fi nishing - 4” to sides of fi replace opening. 3 or vapour barrier coming in contact with the fi replace body,
Inhaltszusammenfassung zur Seite Nr. 15
O GAS VALVE N 15 MANTLE CLEARANCES Combustible mantle clearance can vary according to the FIRESTOP mantle depth. Use the graph SPACER 2" to help evaluate the clearance needed. STUD 1" GAP FROM INSULATION SLEEVE 2" GAP FROM VENTING FIGURE 32 INSULATION 2" SLEEVE 6" MANTLE 13 STAND OFF M H 12 5" SPACER TOP OF 4" A E 11 3" N I 10 2" T G UNIT 11" 9" 9 L H 12" 10" 8" 8 E T 7 0 12 34 5 6 7 TOP OF MANTLE WIDTH FIREPLACE OPENING ELECTRICAL CONNECTION Do NOT use the fi replace if any part has been unde
Inhaltszusammenfassung zur Seite Nr. 16
16 FINISHING / SERVICING OPTIONAL FRONT REMOVAL BOWL AND BURNER REMOVAL 1a. Rectangular Front Removal Start by sliding the bowl forward until it clears the burner then Pull on the top of the optional front away from the fi replace until lift from the fi rebox. Remove the 2 screws located behind the burner then lift up off the orifi ce and out. Then using a the male portion of the latch disengages. Tilt forward slightly fl at head screw driver remove the curved decorative panel. and lift f
Inhaltszusammenfassung zur Seite Nr. 17
17 4. After rocks have been placed on the bowl, add the BLOWER REPLACEMENT remaining rock by inserting the pin into the hole shown in Fig 40. Your comes equipped with a heat circulating blower. The blower is pre-wired and is controlled by the remote con- trol supplied with the unit. For control details, see operation. FIGURE 39 Pg. 20. Drywall dust will penetrate into the blower bearings, caus- ing irreparable damage. Care must be taken to prevent drywall dust from coming into contact
Inhaltszusammenfassung zur Seite Nr. 18
W O D N I W U R H T - E CONTROL PANEL E 18 BATTERY REPLACEMENT 1. Remove the optional front. (Instructions on Pg. 17) 2. Tilt the control panel forward allowing access to the electode box which is screwed to the base of the fi rebox. (Fig. 43) FIGURE 43 BURNER CONTROL PANEL BASE ELECTRODE BURNER BOX BOTTOM (AA Battery Required) CURVED DECORATIVE PANEL BURNER BOWL W415-0583 / B / 05.23.07 S
Inhaltszusammenfassung zur Seite Nr. 19
19 TM NIGHT LIGHT REPLACEMENT TM Your comes equipped with our Night Light . The light has been pre-wired and is controlled from the remote control. If in the event the lamp or lens needs to be replaced, follow the instructions below. GASKET FIGURE 46 LENSE Unplug the wire harness / transformer from the FRAME junction box inside the fi replace or turn off the electrical breaker for the Remove the four screws that secure the lens frame to the fi replace. top of the fi rebox. FIGURE 44 T
Inhaltszusammenfassung zur Seite Nr. 20
20 HAND HELD REMOTE OPERATIONS 1. ON / OFF To turn the fi replace on press the ON / OFF button, the fi replace will always light at maximum fl ame setting. Press the ON / OFF button again to turn the fi replace off. 2. FLAME HEIGHT This function allows remote control of the fl ame height. Check that the Remote Control is on, otherwise, turn on the Remote Control and wait 5 seconds. Select the manual fl ame height until the cursor (small triangle) is to the left of the big fl ame. (Fig. 47) Use t