Inhaltszusammenfassung zur Seite Nr. 1
OM-1500-11 207 750K
2006 −05
Processes
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
(Gas-and Self-Shielding)
Submerged (SAW) Welding
Description
Wire Feeder
(Use with CV Power Sources)
™
SS-74S/D Swingarc
SS-74S12, SS-74S16, SS-74D12, and SS-74D16
File: MIG (GMAW)
Visit our website at
www.MillerWelds.com
Inhaltszusammenfassung zur Seite Nr. 2
From Miller to You Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way. That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy. Today, the people that bu
Inhaltszusammenfassung zur Seite Nr. 3
TABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-3. Additional Symbols For Insta
Inhaltszusammenfassung zur Seite Nr. 4
Inhaltszusammenfassung zur Seite Nr. 5
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _3/05 Warning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. This group of symbols means Warning! Watch Out! possible Marks a special safety message. ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessa
Inhaltszusammenfassung zur Seite Nr. 6
ARC RAYS can burn eyes and skin. BUILDUP OF GAS can injure or kill. Shut off shielding gas supply when not in use. Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays Always ventilate confined spaces or use that can burn eyes and skin. Sparks fly off from the approved air-supplied respirator. weld. Wear an approved welding helmet fitted with a proper shade of fil- ter lenses to protect your face and eyes when welding or watching HOT PART
Inhaltszusammenfassung zur Seite Nr. 7
1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. MOVING PARTS can cause injury. Do not install or place unit on, over, or near Keep away from moving parts such as fans. combustible surfaces. Keep all doors, panels, covers, and guards Do not install unit near flammables. closed and securely in place. Have only qualified persons remove doors, Do not overload building wiring − be sure power supply system is panels, covers, or guards for main
Inhaltszusammenfassung zur Seite Nr. 8
1-5. Principal Safety Standards Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, Boulevard, Rexdale, Ontario, Canada M9W 1R3 (phone: from Global Engineering Documents (phone: 1-877-413-5184, website: 800 −463 −6727 or in Toronto 416 −747 −4044, website: www.csa −in- www.global.ihs.com). ternational.org). Practice For Occupational And Educational Eye And Face Protection, Recommended Safe Practices for the Preparation for Welding and Cut- ANSI Standard Z87.1, from American Na
Inhaltszusammenfassung zur Seite Nr. 9
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION som _3/05 Avertissement : se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes. 2-1. Symboles utilisés Symbole graphique d’avertissement ! Attention ! Cette pro- cédure comporte des risques possibles ! Les dangers éven- tuels sont représentés par les symboles graphiques joints. Ce groupe de symboles signifie Avertissement ! Attention ! Risques Indique un message de sécurité particulier d’É
Inhaltszusammenfassung zur Seite Nr. 10
LES RAYONS D’ARC peuvent entraî- LES ACCUMULATIONS DE GAZ ner des brûlures aux yeux et à la peau. risquent de provoquer des blessures Le rayonnement de l’arc du procédé de soudage ou même la mort. génère des rayons visibles et invisibles intenses Fermer l’alimentation du gaz protecteur en cas (ultraviolets et infrarouges) susceptibles de provo- de non-utilisation. quer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage. Veiller toujours à bien aérer l
Inhaltszusammenfassung zur Seite Nr. 11
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance Risque D’INCENDIE OU D’EXPLO- DES ORGANES MOBILES peuvent SION. provoquer des blessures. Ne pas placer l’appareil sur, au-dessus ou S’abstenir de toucher des organes mobiles tels à proximité de surfaces inflammables. que des ventilateurs. Ne pas installer l’appareil à proximité de Maintenir fermés et verrouillés les portes, produits inflammables. panneaux, recouvrements et dispositifs de pro
Inhaltszusammenfassung zur Seite Nr. 12
2-5. Principales normes de sécurité Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, Boulevard, Rexdale, Ontario, Canada M9W 1R3 (téléphone : de Global Engineering Documents (téléphone : 1-877-413-5184, site In- 800-463-6727 ou à Toronto 416-747-4044, site Internet : ternet : www.global.ihs.com). www.csa-international.org). Practice For Occupational And Educational Eye And Face Protection, Recommended Safe Practices for the Preparation for Welding and Cut- ANSI Standard Z87
Inhaltszusammenfassung zur Seite Nr. 13
SECTION 3 − INTRODUCTION 3-1. Specifications Type of Input Welding Power Wire Feed Speed Wire Diameter Welding Circuit Weight Power Source Type Range Range Rating Standard: 50 To 780 ipm .023 To 1/8 in (0.6 12 ft (3.7 m): 100 Volts, (1.3 To 19.8 mpm) 24 Volts AC Constant Voltage (CV) To 3.2 mm) 160 lb (73 kg) 750 Amperes, 100% Single-Phase DC With 14-Pin And Duty Cycle 10 Amperes Optional High Speed: 92 Contactor Control Max Spool Weight: 16 ft (4.9 m): 50/60 Hertz To 1435 ipm (2.3 To 36.4 60 lb
Inhaltszusammenfassung zur Seite Nr. 14
4-2. Adjusting Control Tilt Bracket 1 Tilt Bracket 2 Rear Pivot Screw 3 Front Screw Loosen rear pivot screw. Remove front screw. Pivot control down- ward to desired viewing angle. Re- place and tighten front screw. Tight- en pivot screw. 1 2 3 803 155 4-3. Installing Boom And Reel Support 1 Swivel Plates 2 Yoke Remove hardware from swivel plates and yoke. 3 3 Boom Set boom into swivel as shown. 7 4 Yoke Pin Install pin through yoke. Install cot- ter pin and spread ends. 5 Bolt 4 Install bolt, ti
Inhaltszusammenfassung zur Seite Nr. 15
4-4. Installing Wire Guide Extension 1 Wire Guide Fitting 1 2 Bolt 3 Monocoil Liner 4 4 Wire Guide Extension Tighten bolt to secure liner in wire 3 2 guide fitting. Do not overtighten bolt and crush liner. Tools Needed: 3/8 in ST-152 323 4-5. Equipment Connection Diagram 1 Welding Power Source 2 Remote 14 Connection 3 Positive (+) Weld Output Cable 1 4 Negative ( −) Weld Output 13 Cable 2 5 Workpiece 6 Weld Control 7 Boom 3 8 Gun 9 Trigger Connection 10 Swivel 12 4 11 Pipe Post And Base 12 Gas H
Inhaltszusammenfassung zur Seite Nr. 16
4-6. Control Box Connections 1 Interconnecting Cable Receptacle 2 Interconnecting Cable 3 14-Pin Control Cable 2 3 1 Ref. 803 019 4-7. 14-Pin Plug Information Pin* Pin Information A 24 volts ac with respect to socket G. B Contact closure to A completes 24 volts ac contactor control circuit. G Circuit common for 24 volts ac circuit. J J A A K K I B C +10 volts dc output to remote control with respect to socket D. L L H H N N C D Remote control circuit common. M M G G D D F E E 0 to +10 volts dc i
Inhaltszusammenfassung zur Seite Nr. 17
4-8. Removing Safety Collar And Adjusting Boom 1 Locking Knob Tighten knob to prevent boom movement. Loosen knob to allow boom movement. Change knob po- sition to limit upward movement. Pull boom down slightly and remove safety collar. Boom should balance in any position from horizontal to 60 degrees above horizontal. If neces- 4 3 sary, adjust boom as follows: 2 Threaded Rod 3 Jam Nut Loosen jam nut and turn threaded rod until boom balances. Tighten jam nut. Be sure several full threads are thr
Inhaltszusammenfassung zur Seite Nr. 18
4-11. Installing And Threading Welding Wire Tools Needed: 15/16, 3/8 in 3/16, 5/64 in Install wire spool. Ad- just tension nut so wire is taut when wire feed stops. Pressure Adjust Pressure Indicator Scale Install wire guide. Pressure Adjust Drive Rolls Install drive rolls. Gun Cable End Of Liner NONCONDUCTIVE NONCONDUCTIVE SURFACE SURFACE No Wire Slip Wire Slips Be sure that outlet cable has proper size For soft wire or small diameter stainless To adjust drive roll pressure, hold nozzle l
Inhaltszusammenfassung zur Seite Nr. 19
4-12. Setting Internal DIP Switches Remove wrapper. 1 DIP Switch S1 On Motor Board PC1 Setting Current Detect Override (S1-1) Current detect override is used to disable run-in when a welding pow- er source is used that doesn’t pro- vide current feedback through the 14-pin receptacle. Pins F & H are not present in 14 pin receptacle on machines that don’t provide current feed- back. Install wrapper when finished. P1 This illustration shows the factory setting of S1. 1 In the DIP switch S1 i
Inhaltszusammenfassung zur Seite Nr. 20
4-13. Optional Equipment DIP Switch Settings (For Models with Meters Only) Remove wrapper. Install wrapper when finished. Digital Meter Functions Standard Standard High Speed High Speed Motor Motor Motor Motor Inches/Minute Meters/Minute Inches/Minute Meters/Minute Or Or Tools Needed: 1/4 in Ref. 803 154 SECTION 5 − OPERATION 5-1. Operational Terms The following is a list of terms and their definitions as they apply to this wire feeder: General Terms: Cold Wire Jog Feeding wire without contacto