Inhaltszusammenfassung zur Seite Nr. 1
WT-5120
433 MHz
Radio Controlled Projection Alarm
Instruction Manual
Inhaltszusammenfassung zur Seite Nr. 2
TABLE OF CONTENTS Topic Page Inventory of Contents/ Additional Equipment 3 About WWVB 3 Quick Set-Up Guide 4 Detailed Set-Up Guide Battery Installation 5 Program Mode Programming Sequence 6 Function Buttons 6 Manual Time Setting 6 Time Zone Setting 6-7 Daylight Saving Time (DST) Setting 7 Features & Operations Features 8 Radio-Controlled Time 8 Projection 8 EL Backlight 9 Indoor Temperature 9 Indoor Humidity 9 Remote Temperature 9 Time A
Inhaltszusammenfassung zur Seite Nr. 3
INVENTORY OF CONTENTS 1) WT-5120 Alarm Clock 2) TX6U Remote temperature sensor 3) AC adapter/transformer 4) Instruction manual and warranty card. ADDITIONAL EQUIPMENT (not included) 1) Two fresh 1.5V AA batteries (optional for projection alarm clock) 2) Two fresh 1.5V AA batteries (for remote temperature sensor) FEATURES OF PROJECTION ALARM Operation of these features is in section III 1. Radio-controlled time 2. Projection of time and/or remote temperature 3. EL backlight 4
Inhaltszusammenfassung zur Seite Nr. 4
QUICK SET-UP GUIDE Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries. 1. Have the projection alarm and remote temperature sensor 3 to 5 apart. 2. Batteries should be out of both units for 10 minutes. 3. Place the batteries into the remote temperature sensor first then into the projection alarm. 4. DO NOT PRESS ANY BUTTONS FOR 15 MINUTES. In this time the display and sensor will start to talk to each other and the display will show both the indoor temperatu
Inhaltszusammenfassung zur Seite Nr. 5
DETAILED SET-UP GUIDE II. BATTERY INSTALLATION A. REMOTE TEMPERATURE SENSOR 1. Remove the battery cover. 2. Observing the correct polarity, install 2 AA batteries. The Battery batteries will fit tightly (to avoid start-up problems make Cover sure that they do not spring free during installation). 3. Replace the battery cover. B. PROJECTION ALARM 1. Remove the battery cover. 2. Observe the correct polarity, and install 2 AA batteries. 3. In addition or instead of insert
Inhaltszusammenfassung zur Seite Nr. 6
III. PROGRAM MODE To enter the Program Mode hold down the “MODE/MIN” button for 3 seconds, until the time flashes in the top of the display. The Program Mode Guide is laid out in a manner that allows you to program each function separately, or you can follow the instructions entirely to program the projection alarm. Complete programming is usually done for the initial set-up, and will require you to skip step 1 and 2 of programming sections D and E. To exit the setting mode simply wait
Inhaltszusammenfassung zur Seite Nr. 7
4. Press and release the “MODE/MIN” button to select the appropriate time zone. There are 24 time zones to choose from (based relative to the international time standard of GMT (“Greenwich Mean Time). NOTE: The U.S. time zones will show abbreviations as opposed to the numerical time zone indicator. For example Eastern Time will display “ET” when the Eastern Time Zone is selected 5. Press and release the “SET” button to confirm the time zone setting and to advance to the DST (Daylig
Inhaltszusammenfassung zur Seite Nr. 8
IV. FEATURES & OPERATIONS A. FEATURES 1. Radio-controlled time 2. Projection of time and/or remote temperature 3. LED backlight 4. Display of indoor temperature/humidity or alarm time 5. Indoor temperature and humidity 6. Remote outdoor temperature 7. Time alarm B. RADIO-CONTROLLED TIME 1. The projection alarm will automatically search for the time signal upon initial set-up and every night. 2. When the signal is being received, there will be a “tower” icon flashing to the left
Inhaltszusammenfassung zur Seite Nr. 9
D. EL BACKLIGHT 1. The projection alarm has an EL backlight designed for night-viewing. This will light up for 4 seconds whenever the snooze button is pressed. 2. The EL backlight cannot be turned on constantly; this would drain the batteries. E. INDOOR TEMPERATURE 1. The projection alarm measures indoor temperature with an internal sensor. 2. This temperature is displayed in °F. 3. The indoor temperature will take time to adjust to the surrounding temperature as the sensor is ins
Inhaltszusammenfassung zur Seite Nr. 10
H. TIME ALARM 1. SETTING THE ALARM a. Press and hold “AL/HOUR” button for three seconds until the alarm time is flashing. b. Press and release “AL/HOUR” to advance the hour, and “MODE/MIN” to advance the minute. The time will display “PM” if set to PM, and nothing if set to AM. c. The projection alarm will revert to normal operation when no buttons are pressed for 15 seconds. The alarm is now set and activated. 2. ACTIVATING/DEACTIVATING THE ALARM a. After entering the alarm setti
Inhaltszusammenfassung zur Seite Nr. 11
V. MOUNTING THE REMOTE TEMPERATURE SENSOR The remote temperature sensor can be mounted in two ways: 1) Using screws 2) Using the adhesive tape. A. MOUNTING WITH SCREWS 1. Remove the mounting bracket from the remote temperature sensor. The bracket should snap off easily. 2. Place the mounting bracket over the desired location. Through the three screw holes of the bracket, mark the mounting surface with a pencil. 3. Where marked, start the screw holes into the mounting surface. 4
Inhaltszusammenfassung zur Seite Nr. 12
TROUBLESHOOTING Problem: The Projection is faint 1) Use AC adapter Solution: 2) Darken surroundings 3) Use fresh batteries (if AC is not used) Problem: The LCD is faint. Solution: Replace the batteries. Problem: “OFL” appears in the indoor temperature LCD. 1) Move unit to an area with warmer or cooler surrounding Solution: temperature. 2) Current surrounding temperatures are outside measuring range. Problem: No reception of WWVB signal. 1) It may help reception to face the front of
Inhaltszusammenfassung zur Seite Nr. 13
SPECIFICATIONS FOR WT-5120 Temperature: 14 °F to 99 °F with 0.2 °F resolution (indoor) Measuring range: -21.8 °F to 156.2 °F with 0.2 °F resolution (outdoor) Every 10 seconds indoor, 2 times in 10 minutes for Checking intervals: remote temperature. Humidity: Measuring range: 1 – 99 % Checking intervals: Every 10 seconds Power source: AC Adapter (included) Input: 120VAC/60Hz Output: DC 3.2V/100MA Projection Alarm: 2 x AA, 1.5V (Alkaline) (optional) Battery type: Sensor: 2 x AA, 1.5
Inhaltszusammenfassung zur Seite Nr. 14
WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North America and only to the original purchaser of this product. To receive warranty service, the purchaser must contact La Crosse Technology, Ltd for problem determination and service procedures. Warranty service can
Inhaltszusammenfassung zur Seite Nr. 15
For warranty work, technical support, or information contact: La Crosse Technology, Ltd 2809 Losey Blvd S. La Crosse, WI 54601 Phone: 608.782.1610 Fax: 608.796.1020 e-mail: support@lacrossetechnology.com (warranty work) sales@lacrossetechnology.com (information on other products) web: www.lacrossetechnology.com All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, mechanical or chemical p