Inhaltszusammenfassung zur Seite Nr. 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY
THIS MANUAL IS PRINTED ON RECYCLED PAPER
ACCENT 25BV
By SHERWOOD INDUSTRIES LTD.
OWNERS MANUAL
WARNING
WHAT TO DO IF YOU SMELL GAS
If the information in this
• Open windows/Extinguish any open flame
manual is not followed exactly,
• Do not try to light any appliance.
a fire or explosion may result
• Do not touch any electrical switch; do not use any
causing property damage,
phone in your building
Inhaltszusammenfassung zur Seite Nr. 2
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" HEATER, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: • All "ENVIROGAS" gas-fired appliances must be installed in accordance with these instructions. • To prevent injury do not allow anyone who is Carefully read all the instructions in this manual first. unfamiliar with the operation to use the stove. Consult the building authority having jurisdiction to determine the need for a permit prior to commen
Inhaltszusammenfassung zur Seite Nr. 3
TABLE OF CONTENTS SECTION PAGE 1. Code Approvals 3 2. Dimensions and Clearances to Combustibles 5 3. Venting 6 4. Assembly and Installation Instructions 7 5. Electrical Requirements 8 6. Gas Line Connection and Testing 9 7. Installation of Log Sets and Embers and Brick Panels 10 8. Operating Instructions 11 9. Routine Maintenance and Service 12 10. Fuel Conversion 13 11. Trouble Shooting 14 12. Parts and Accessories 15 13. Warranty 16 14. Installation Data Sheet 17 1. CODES
Inhaltszusammenfassung zur Seite Nr. 4
CODES AND APPROVALS CONTINUED RE: CONVERSION OF ZERO CLEARANCE FACTORY BUILT FIREPLACES The following instructions cover Sherwood Industries Ltd. policy for Gas-Fired Appliances (inserts) to be retofitted into existing factory built fireplaces with replacement parts removed. GENERAL REQUIREMENTS Background A gas fired insert is approved for use in an existing masonry or a listed factory built fireplace without any alterations. If the factory or masonry fireplace is altered its war
Inhaltszusammenfassung zur Seite Nr. 5
2. DIMENSIONS AND CLEARANCES TO COMBUSTIBLES DISTANCE TO COMBUSTIBLES: Mantel pillar to surround panel 2" / 5.08 cm Floor to 8" wide mantel 40" / 101 cm Minimum non-combustible surface in front of unit 8" / 20.8 cm OTHER DIMENSIONS A. Minimum Depth of unit into fireplace 16" / 41 cm B. Depth of unit out of fireplace 1 / 2.54 cm C. Minimum firebox size W 27" x H 22” x D 17" (W 68.5 x H 55.8 x D 43.1 cm) Maintain sufficient clear
Inhaltszusammenfassung zur Seite Nr. 6
3.VENTING FIREPLACE INSERTS WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. The Envirogas ACCENT 25 may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials. An approved full length chimney liner and rain cap mu
Inhaltszusammenfassung zur Seite Nr. 7
4. ASSEMBLY AND INSTALLATION INSTRUCTIONS ASSEMBLING AND INSTALLING YOUR ENVIROGAS ACCENT 25 1. Remove the unit from it’s box DRAFT HOOD 2. Open the door, by first removing the cover with the nameplate ADJUSTMEN attached (open valve door and pull nameplate cover T SCREWS side tab to release catch), undo the two bolts at the bottom of the door. Lift the door up and out to remove. CAUTION GLASS MAY SEPARATE FROM DOOR. 3. Remove log and ember set and all wrapping material fr
Inhaltszusammenfassung zur Seite Nr. 8
5. ELECTRICAL REQUIREMENTS The ACCENT 25 will operate without electrical power. This model has a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burners. The appliance when equipped with blower must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL COD
Inhaltszusammenfassung zur Seite Nr. 9
6. GAS LINE CONNECTIONS and TESTING WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a 3/8 x 3 inch black iron nipple located on the right side of the unit terminating in a 3/8" male NPT fitting. Consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code in Canada, or in the USA gas installations follow either local codes or the current edition o
Inhaltszusammenfassung zur Seite Nr. 10
7. INSTALLATION OF LOGS, EMBERS and BRICK PANELS REMOVING AND INSTALLING THE BRICK PANELS INSTALLING THE GLOWING EMBERS and LOGSET A bag of ceramic fiber embers is provided for use on the burner PAN. Open the door. Remove the log set. CAUTION: Use only the type of ember material supplied Optional ceramic panels: Remove burners. Gently pull right brick side panel inwards from the bottom back. Pull with this appliance. Due to the irregular size of the ember material there may
Inhaltszusammenfassung zur Seite Nr. 11
8.OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must • If you cannot reach your gas supplier, call the be lit by hand by following these instructions exactly. fire department. B) BEFORE LIGHTING smell all around the appliance C) Use only your hand to push in or turn the ga
Inhaltszusammenfassung zur Seite Nr. 12
9. ROUTINE MAINTENANCE and SERVICE Periodically check to ensure that your system is clean. After carefully replacing the log and embers in their correct positions, and the door has been resealed, re-light the Periodically check the pilot and burner. Check to see that pilot, following the instructions on the attached label. all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue CLEARANCES MUST BE SUFFICIENT TO ALLOW with yel
Inhaltszusammenfassung zur Seite Nr. 13
10.FUEL CONVERSION “Warning” This conversion kit shall be installed by a qualified service technician in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or CO poisoning may result. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper or complete until the operat
Inhaltszusammenfassung zur Seite Nr. 14
11. TROUBLE SHOOTING Problem Possible Cause Solution Spark will not arc to the pilot after Defective piezo ignitor Check connections to ignitor repeated pressing of spark ignitor -If ignitor connections are good but there is no spark-replace ignitor Broken spark electrode -Check for broken ceramic insulation replace, electrode if broken Miss-aligned spark electrode -If spark is not arcing from the electrode to pilot- adjust by loosening screws on pilot base. Adjust away from
Inhaltszusammenfassung zur Seite Nr. 15
12. PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer. PART # DESCRIPTION EG25-001 Convection Blower EG25-002 Heyco Strain Relief EG25-003 Fan Controller with Knob EG25-004 Hi-Temperature Electrical Cord EG25-008 Burner Switch EG25-014 120°F Ceramic Auto Reset n/o Temp Sensor (big foot) EG25-015 300°F Temp Sensor n/c Ceramic (spill switch) EG25-018 Wire Harness EG25-026 Valve Access Door Magnet EG25-030 Blank Orifice EG25-031 Thermocouple EG25-
Inhaltszusammenfassung zur Seite Nr. 16
120° F (49° C) FAN DRAFT HOOD TEMPERATURE FULLY SLIDER SENSOR ASSEMBLED EC-001 PILOT EC-015 NG EC-016 LP THERMOPILE BRICK CLIPS 300° F AND BACK EC-012 CERAMIC (149° C) LEDGE THERMOCOUPLE BRICK SPILL EC-009 PAN BURNER LINERS SWITCH SPARK POST APR 2000 EG25-074 EC-003 ELECTRODE EC-011 BLACK IRON NIPPLE EG25-062 LEVELING LEGS X 2 LOUVER SET (TOP & BOTTOM) EG25-115 PIEZO RATING IGNITER PAINTED LABEL EC-023 DOOR PLATE EG25-092 CONVECTION CONVECTION BLOWER
Inhaltszusammenfassung zur Seite Nr. 17
ON / OFF / THERMOSTAT SWITCH BURNER BRASS TRIM SWITCH CORNER EC-026 BRACKETS (NOT SHOWN) EC053 FAN CONTROLLER EC-039 ACCENT 25 OVERSIZE FPI WIRING SURROUND WITH HARNESS PART (A) PAINTED TRIM 50-108 EC-034 ACCENT 25 BRASS TRIM (NOT SHOWN) 50-013 REGULAR NICKEL TRIM SURROUND WITH 50-014 TRIM PAINTED TRIM 50-107 BRASS TRIM 50-011 NICKEL TRIM 50-012 ACCENT 25 EXPLODED VIEW SURROUND PANELS PAGE 1of 2 JUNE 2002 17
Inhaltszusammenfassung zur Seite Nr. 18
13. WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifetime warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location Covered under the lifetime warranty are Cabinet Sides, Tops, Pedestals, Surround Panels and Chassis and Heat Exchanger. These steel components are covered against manufacturer’s defects for 5 years and labor for the first year
Inhaltszusammenfassung zur Seite Nr. 19
14. INSTALLATION DATA SHEET The following information must be recorded by the installer for warranty purposes and future reference. Envirogas Model: ACCENT 25 BV Name of Dealer: Name of Owner: ___________________________________________ __________________________________________ Address: Address: ___________________________________________ __________________________________________ ___________________________________________ ___________________________________