Inhaltszusammenfassung zur Seite Nr. 1
Multi-Deck Warmer
MODEL MDW
Installation & Operation Manual
Serial Numbers 121764 and Higher
Inhaltszusammenfassung zur Seite Nr. 2
Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the original purchaser that at time of shipment from the Company factory, this equipment will be free from defect in materials and workmanship. Written notice of a claim under this warranty must be received by the Company within ONE YEAR from the date of installation, but no longer than ONE YEAR AND THREE MONTHS from date of shipment from the factory. Defective conditions caused by abnormal use or misuse, la
Inhaltszusammenfassung zur Seite Nr. 3
Multi-Deck Warmer Table of Contents Table of Contents Table of Contents........................................................................................................................................1 Introduction .................................................................................................................................................2 Safety Precautions........................................................................................................
Inhaltszusammenfassung zur Seite Nr. 4
Multi-Deck Warmer Introduction Introduction The MDW is a multi-tier, self-serve hot food merchandiser. It consists of heated glass shelves, individual shelf lighting, and electronics for powering the shelves, lighting the shelves and controlling the temperature of each shelf. This unit is for use with prepackaged foods only. This unit is manufactured by BKI which assures you of the finest in design and engineering -- that it has been built with care and dedication -- using the best ma
Inhaltszusammenfassung zur Seite Nr. 5
Multi-Deck Warmer Safe Work Practices Beware of High Voltage This equipment uses high voltage. Serious injury can occur if you or any untrained or unauthorized person installs, services, or repairs this equipment. Always Use an Authorized Service agent to Service Your Equipment Beware of Hot Surfaces. Do Not Touch. The shelves in this unit reach temperatures that can cause burns. Use caution when placing product on and removing product from the shelves. Do not touch any of the sh
Inhaltszusammenfassung zur Seite Nr. 6
Multi-Deck Warmer Operation Operation Controls and Indicators Refer to Figure 1 and the following sections for an explanation of controls and indicators. Shelf Power/Lighting The POWER ON/OFF circuit breaker allows you to turn all shelves ON or OFF. This device provides overload, short circuit and ground fault protection. When an overload or earth leakage ground fault condition occurs, the circuit breaker will trip causing the actuator to move to the OFF position and the leakage trip
Inhaltszusammenfassung zur Seite Nr. 7
Multi-Deck Warmer Operation Foods held for long periods of time are more difficult to maintain at proper temperature. Also, freshness and product quality diminish if foods are held too long. Most areas of the country have sanitation regulations governing how long foods can be held. Make certain to check with your local authorities. Unit Shutdown 1. Remove product from the unit. 2. Place the POWER ON/OFF circuit breaker in the OFF position. 3. Place the LIGHTS ON/OFF circuit breake
Inhaltszusammenfassung zur Seite Nr. 8
Multi-Deck Warmer Installation Installation Unpacking and Handling YOU are responsible for filling all freight claims with the delivering truck line. Inspect all cartons and crates for damage as soon as they arrive. If damage to cartons or crates is found, or if a shortage is found, note this on the bill of lading (all copies) prior to signing. If damage is found when the equipment is opened, immediately call the delivering truck line and follow up the call with a written report indi
Inhaltszusammenfassung zur Seite Nr. 9
Multi-Deck Warmer Installation Figure 2. Floor Model – Leveling & Kick Plate Mounting 7
Inhaltszusammenfassung zur Seite Nr. 10
Multi-Deck Warmer Installation Counter Model Counter mounted units must be mounted on a level surface that can support the weight of the unit and it’s contents. Use a carpenter’s level to level the unit. These units are to be sealed to the counter if required by local health codes. Seal the perimeter of the units to the counter using a silicone-type sealant (Dow Corning RTV #732 or equivalent). Caster Model Caster mounted units must be moved to a permanent location and the two swiv
Inhaltszusammenfassung zur Seite Nr. 11
Multi-Deck Warmer Maintenance Maintenance Failure to comply with the maintenance below could result in a serious accident. Electrocution, equipment failure or property damage could result if an unlicensed electrician performs electrical repair. Ensure that a licensed electrician performs electrical repair. Scheduled Maintenance Use the following table to help manage scheduled maintenance activities. Frequency Performed By Part Activity Daily User Unit Clean the entire Unit
Inhaltszusammenfassung zur Seite Nr. 12
Multi-Deck Warmer Maintenance Troubleshooting Refer to the table below for troubleshooting information. Problem Cause Possible Solution Shelves Not Heating and Unit not plugged into power Ensure unit power cord is Lights Not On receptacle. connected to appropriate power receptacle. No Power to the unit. Check circuit breaker or fuses at building power panel. If problem persists, contact an authorized BKI service agent for corrective action. Power circuit breaker is OFF Place
Inhaltszusammenfassung zur Seite Nr. 13
Multi-Deck Warmer Notes Notes 11
Inhaltszusammenfassung zur Seite Nr. 14
Multi-Deck Warmer Notes 12
Inhaltszusammenfassung zur Seite Nr. 15
Multi-Deck Warmer Notes 13
Inhaltszusammenfassung zur Seite Nr. 16
P.O. Box 80400, Simpsonville, S.C. 29680-0400, USA http://www.bkideas.com Made and printed in the U.S.A LI0189/0407