Inhaltszusammenfassung zur Seite Nr. 3
Contents PREPARING YOUR AIR CONDITIONER Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . . . 6 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 4
View of the Unit The design and shape are subject to change according to the model. Indoor Unit On/Off switch Air filter Air Inlet Remote Control Sensor (under the grille) Air flow blades (outlet) TURBO indicator (RED) Energy Saving indicator (GREEN) Operation indicator Timer indicator (Cooling-GREEN, (YELLOW) Heating-RED) E-4
Inhaltszusammenfassung zur Seite Nr. 5
Outdoor Unit UQ07S8GE SH07ZS8X UQ09S8GE SH09ZS8X Air Inlet(Rear) SH30ZC1(C2)X Air Outlet Connection Valve (inside) Outdoor Unit UQ07SBGE UQ09SBGE UQ12SBGE Air Inlet(Rear) Air Outlet Connection Valve Outdoor Unit UQ12SGGB UQ12SGGE SH12ZSGX Air Inlet(Rear) Air Outlet Connection Valve (inside) Outdoor Unit UQ18S0GB UQ18S0GE SH18ZS0X UQ24S6GB UQT24S6GE SH24TS6X Air Inlet(Rear) Air Outlet Connection Valve E-5
Inhaltszusammenfassung zur Seite Nr. 6
Remote Control - Buttons and Display Remote control transmission indicator Mode selection button (AUTO, COOL, DRY, FAN, HEAT) Operating mode ( AUTO, COOL, DRY, FAN, HEAT) Temperature adjustment Temperature setting buttons Turbo mode Turbo/Sleep mode Sleep mode selection button Energy saving Fan speed adjustment button Fan speed Swing button Air flow direction On Timer setting On Timer button Off Timer setting Off Timer button Battery discharge indicator On/Off & Energy
Inhaltszusammenfassung zur Seite Nr. 7
Getting Started You have just purchased a split type air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features. The booklet is organized as follows. The following figures are shown on pages from 4 to 6 : - Indoor and outdoor units - Remote control(buttons and display) They will help you find the
Inhaltszusammenfassung zur Seite Nr. 8
Inserting the Remote Control Batteries You must insert or replace the remote control batteries when : You purchase the air conditioner The remote control does not work correctly N No ot te e Use two AAA, LR03 1.5V batteries. N No ot te e Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used. 1 Push the battery cover on the rear of the remote control with your thumb in the d
Inhaltszusammenfassung zur Seite Nr. 9
Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. 1 If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit bee
Inhaltszusammenfassung zur Seite Nr. 10
Cooling Your Room You must select the Cool mode if you wish to adjust the: Cooling temperature Fan speed when cooling 1 If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. IMPORTANT The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: P
Inhaltszusammenfassung zur Seite Nr. 11
Heating Your Room You must select the Heat mode if you wish to adjust the: Heating temperature Fan speed when heating 1 If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. The air conditioner is fitted with a protection mechanism IMPORTANT to prevent the unit from being damaged when it is started immediately after being: Plug
Inhaltszusammenfassung zur Seite Nr. 12
Changing the Room Temperature Quickly The Turbo cooling/heating function is used to cool or heat your room as quickly as possible. E E E Ex x x xa a a am m m mp p p plllle e e e : You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected. 1 If necessary, press the (On/Off) button. Result:
Inhaltszusammenfassung zur Seite Nr. 13
Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. 1 If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. IMPORTANT The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is star
Inhaltszusammenfassung zur Seite Nr. 14
Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. 1 If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. 2 If the is not displayed at the top of the remote control, press the button on the remote control one or more times until it appears. Result: The indoor unit beeps ea
Inhaltszusammenfassung zur Seite Nr. 15
Selecting Energy Saving Mode If you wish to save energy when using your air conditioner, select the Energy saving mode with the Energy saving button. 1 If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. IMPORTANT The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started
Inhaltszusammenfassung zur Seite Nr. 16
Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. 1 Press the button one or more times as required. Result: The outer blade is adjusted vertically. RECOMMENDATION When... Adjust the blade to face... Cooling Upwards. Heating Downwards. 2 If you want the blade to move up and down automati
Inhaltszusammenfassung zur Seite Nr. 1
OWNER’S
INSTRUCTIONS
Indoor unit Outdoor unit
AQ07S8GE UQ07S8GE
AQ07SBGE UQ07SBGE
SH07ZS8 SH07ZS8X
AQ09S8GE UQ09S8GE
AQ09SBGE UQ09SBGE
SH09ZS8 SH09ZS8X
AQ12SBGE UQ12SBGE
AQ12SGGB UQ12SGGB
AQ12SGGE UQ12SGGE
SH12ZSG SH12ZSGX
AQ18S0GB UQ18S0GB
AQ18S0GE UQ18S0GE
SH18ZS0 SH18ZS0X
AQ24S6GB UQ24S6GB
AQT24S6GE UQT24S6GE
SH24TS6 SH24TS6X
SPLIT TYPE ROOM AIR CONDITIONER
( Cool and Heat )
E DB98-08237A(5)
Inhaltszusammenfassung zur Seite Nr. 2
Safety Precautions If the power supply cord of this air conditioner is damaged, it must WARNING be replaced by the manufacturer or its authorized service personnel only in order to avoid a safety hazard. Do not attempt to install the air conditioner by yourself. DANGER This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs. When moving, consult authorized service personnel for disconnection and installation of the unit. Do not become over
Inhaltszusammenfassung zur Seite Nr. 17
Adjusting the Air Flow Direction Horizontally There are two sets of inner air flow blades. Just as the outer air flow blade can be adjusted vertically, the inner blades can be adjusted horizontally. 1 Adjust each set of inner blades to the required position, by pushing or pulling them sideways. E-17
Inhaltszusammenfassung zur Seite Nr. 18
Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusive. 2 Press the (Set/Cancel) button to complete the setting. Result: The remaining time is displayed. Blinking of the timer indicator stops. The sel
Inhaltszusammenfassung zur Seite Nr. 19
Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusive. 2 Press the (Set/Cancel) button to complete the setting. Result: The remaining time is displayed. Blinking of the timer indicator stops. The
Inhaltszusammenfassung zur Seite Nr. 20
Setting the Sleep Timer The Sleep Timer can be used when you are cooling or heating your room to switch the air conditioner off automatically after a period of six hours. N N N No o o ot t t te e e e If you wish to switch the unit off at a specific time, refer to page 19. 1 Make sure that you have selected either COOL or HEAT mode. 2 Press the button one or more times until appears on the remote control. Result: The indoor unit beeps. The air conditioner will be controlled as