Inhaltszusammenfassung zur Seite Nr. 1
UC100 Installation Manual
INSTALLATION MANUAL
Starbucks UC100 Progate Ice Dispenser
DESCRIPTION
The UC100 Progate ice dispenser solves your ice service needs in a sanitary, space saving, economical
way. Designed to be manually filled with Ice-O-Matic half cube ice.
CAUTION: The dispenser cannot be used with crushed or flaked ice. Use of bagged ice
which has frozen into large chunks can void warranty. The dispenser agitator is not
designed to be an ice crusher. Use of large chunks of ice whi
Inhaltszusammenfassung zur Seite Nr. 2
UC100 Installation Manual SAFETY INSTRUCTIONS Read and Follow all Safety Instructions Read and follow all safety instructions in this manual and on the machine (decals, labels, and laminated cards). Read and understand all applicable OSHA (Occupation Safety and Health Administration) safety regulations before operating the machine. Recognize Safety Alerts This is the safety alert symbol. When you see it in this manual or on the machine be alert to the potential of personal injury or damage to
Inhaltszusammenfassung zur Seite Nr. 3
UC100 Installation Manual SAFETY PRECAUTIONS This ice dispenser has been specifically designed to provide protection against personal injury and eliminate contamination of ice. To ensure continued protection and sanitation, observe the following: IMPORTANT: Disconnect power to the dispenser before servicing or cleaning. NEVER: place hands inside of hopper or gate area without disconnecting power to the dispenser. Agitator rotation occurs automatically when dispenser is energized! ALWAYS: be
Inhaltszusammenfassung zur Seite Nr. 4
UC100 Installation Manual INSTALLATION INSTRUCTIONS IMPORTANT: It is the responsibility of the Installer to ensure that the water supply to the dispensing equipment is provided with protection against backflow by an air gap as defined in ANSI/ASME A112. 1.2–1979; or an approved vacuum breaker or other such method as proved effective by test. 1. Locate the dispenser indoors on a level counter top. A. Caster Option Unpack the four (4) casters and install them into the threaded holes provided
Inhaltszusammenfassung zur Seite Nr. 5
UC100 Installation Manual 3. The dispenser drain lines must slope a minimum of 1/4” per foot to the floor drain, see FIGURE 2. Drain lines must be installed to comply with federal, state and local codes. It is required to fully insulate all drain lines and fittings to prevent condensation from forming!!! Dispenser Drain Line Drain Point Horizontal Reference Line 1/4” 1’ Floor Drain FIGURE 2 If the unit is installed in a: 36” tall counter top, the floor drain must be within 23’ of the dispen
Inhaltszusammenfassung zur Seite Nr. 6
UC100 Installation Manual Adjust Carbonator CO Regulator (if applicable) 2 CAUTION: Before connecting the CO regulator assembly to a CO cylinder, turn the regulator 2 2 adjusting screw to the left (counterclockwise) until all tension is relieved from the adjusting screw spring. 1. Open (counterclockwise) CO cylinder valve slightly to allow lines to slowly fill with gas, then open 2 the valve fully to back-seat the valve. (Back-seating the valve prevents leakage around the valve shaft). 2.
Inhaltszusammenfassung zur Seite Nr. 7
UC100 Installation Manual PR (Prime) - This code will display when the unit has just been powered. ICE - When displayed, ice levels are low or close to empty inside the hopper. LOC (Lock) - When displayed, check to make sure that ice bin covers, ice chute transition, piece ice flapper and ice chute are attached properly. Once secured, push the “M” button on the keypad to return to dispense mode. FILL - When displayed, all ice has been consumed and needs to be replaced. Refill the ice bin. Clo
Inhaltszusammenfassung zur Seite Nr. 8
UC100 Installation Manual 5. To save the new programmed size, press the P and the Blended Short (S) buttons simultaneously until the screen clears. If no action is taken within 60 seconds, dispense mode will resume and any changes will not be saved. FIGURE 5 Publication Number: 621054211INS - 8 - © 2008, IMI Cornelius Inc.
Inhaltszusammenfassung zur Seite Nr. 9
UC100 Installation Manual TROUBLESHOOTING IMPORTANT: Only qualified personnel should service internal components or electrical wiring. WARNING: If repairs are to be made to the CO or air system, stop dispensing, shut off the 2 CO or air supply, then relieve the system pressure before proceeding. If repairs are to be 2 made to the ice dispensing system, make sure electrical power is disconnected from the unit. Trouble Probable Cause Remedy NOTE: Should your unit fail to operate properly, c
Inhaltszusammenfassung zur Seite Nr. 10
UC100 Installation Manual Publication Number: 621054211INS - 10 - © 2008, IMI Cornelius Inc.