Inhaltszusammenfassung zur Seite Nr. 1
INSTRUCTION MANUAL
Air Cleaner
(Model AP200)
PART NO. 906565 - 07-18-02
Copyright © 2002 Delta Machinery
To learn more about DELTA MACHINERY
ESPAÑOL: PÁGINA 13
visit our website at: www.deltamachinery.com.
For Parts, Service, Warranty or other Assistance,
please call 1-800-223-7278 (In Canada call 1-800-463-3582).
Inhaltszusammenfassung zur Seite Nr. 2
GENERAL SAFETY RULES Woodworking can be dangerous if safe and proper operating procedures are not followed. As with all machinery, there are certain hazards involved with the operation of the product. Using the machine with respect and caution will considerably lessen the possibility of personal injury. However, if normal safety precautions are overlooked or ignored, personal injury to the operator may result. Safety equipment such as guards, push sticks, hold-downs, featherboards, goggles, dust
Inhaltszusammenfassung zur Seite Nr. 3
ADDITIONAL SAFETY RULES FOR AIR CLEANERS 1. DANGER: DO NOT USE THIS UNIT TO FILTER METAL DUST. Combining wood and metal dust can create an explosion or fire hazard. This unit is intended to filter non-explosive atmospheres only. 2. WARNING: DUST GENERATED BY CERTAIN WOODS AND WOOD PRODUCTS CAN BE HAZARDOUS TO YOUR HEALTH. 3. WARNING: DO NOT USE THIS UNIT TO DISSIPATE FUMES OR SMOKE. This air cleaner is intended for use where only dry airborne dust is present. Its use should be limited to non-exp
Inhaltszusammenfassung zur Seite Nr. 4
POWER CONNECTIONS A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3- prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the motor to the power line, make sure the switch is in the “OFF” position and be sure that the electric current is of the same characte
Inhaltszusammenfassung zur Seite Nr. 5
EXTENSION CORDS Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D, shows the correct gauge to use depending on the cord length. If in
Inhaltszusammenfassung zur Seite Nr. 6
AIR CLEANER PARTS 1 2 3 4 Fig. 2 1 - Air cleaner 2 - Four 5/16-18x1½" eye-bolts 3 - Four 5/16-18 flange nuts 4 - Four rubber feet 6
Inhaltszusammenfassung zur Seite Nr. 7
ASSEMBLY INSTRUCTIONS WARNING: FOR YOUR OWN SAFETY, DO NOT CONNECT THE MACHINE TO THE POWER SOURCE UNTIL THE MACHINE IS COMPLETELY ASSEMBLED AND YOU READ AND UNDERSTAND THE ENTIRE INSTRUCTION MANUAL. The Air Cleaner requires very little assembly; therefore, determine in which position the Air Cleaner will be used - on the floor, bench or overhead. If the Air Cleaner will be used as a mobile unit, proceed to “USING THE AIR CLEANER ON A BENCH OR FLOOR SURFACE” section. If ceiling mounting, proceed
Inhaltszusammenfassung zur Seite Nr. 8
MOUNTING THE AIR CLEANER TO THE CEILING OR OVERHEAD SUPPORT WARNING: THIS TOOL WEIGHS APPROXIMATELY F 50 POUNDS. MAKE CERTAIN THE UNIT IS SECURELY C SUPPORTED WHEN MOUNTING TO A CEILING OR OVERHEAD SUPPORT. 1. Remove four screws, one of which is shown at (C) E Fig. 5, from the top of air cleaner (D). 2. Thread 5/16-18 flange nut (E) Fig. 5, approximately half-way onto 5/16-18x1½" eye-bolt (F), as shown. D 3. Thread eye-bolt (F) Fig. 5, into hole where screw (C) was removed in STEP 1. NOTE: THREA
Inhaltszusammenfassung zur Seite Nr. 9
OPERATING CONTROLS ON/OFF SWITCH M The Air Cleaner is equipped with an in-line rocker switch (M) Fig.11, located on the power cord (N). To start or stop the motor, press downward on the rocker switch. N NOTE:The switch has markings on the side to determine the on/off position. We suggest that when finished with the air cleaner, the switch be turned off rather than unplugging the unit. Fig. 11 OPERATIONS 1. NOTE: The air cleaner may produce a slight odor for the first couple hours of operation du
Inhaltszusammenfassung zur Seite Nr. 10
5. Fig. 16, illustrates the air cleaner being used in a floor sanding application. Fig. 16 6. Fig. 17, illustrates the air cleaner suspended from wooden ceiling supports for overhead operation. WARNING:Keep a minimum of seven feet between bottom of air cleaner and the floor surface. When suspending the air cleaner from the ceiling or other overhead support, make certain the supporting hardware (not supplied)is securely anchored into a wooden supporting structure as shown in Fig. 17. WARNING: NEV
Inhaltszusammenfassung zur Seite Nr. 11
3. Remove inner bag filter (J)Fig. 19, in the same manner. 4. The first stage filter (H) Fig. 18, can be replaced or cleaned depending on its condition. This filter can be cleaned in one of two methods: a shop-vac can be used to remove the dust, or compressed air can be used to blow the dust out of the filter. WARNING: COMPRESSED AIR CAN BE DANGEROUS. FOR OPERATOR SAFETY, DO NOT EXCEED AN AIR PRESSURE OF 30 PSI OR POINT AIR J NOZZLE TOWARD ANYONE OR AIM AIR NOZZLE AT YOUR OWN BODY. ALWAYS WEAR S
Inhaltszusammenfassung zur Seite Nr. 12
ACCESSORIES A complete line of accessories is available from your Delta Supplier, Porter-Cable • Delta Factory Service Centers, and Delta Authorized Service Stations. Please visit our Web Site www.deltamachinery.com for a catalog or for the name of your nearest supplier. WARNING: Since accessories other than those offered by Delta have not been tested with this product, use of such accessories could be hazardous. For safest operation, only Delta recommended accessories should be used with th