Inhaltszusammenfassung zur Seite Nr. 1
INSTRUCTION MANUAL
Air Cleaner
50-875
PART NO. 907370 - 02-25-04
Copyright © 2004 Delta Machinery
To learn more about DELTA MACHINERY
ESPAÑOL: PÁGINA 11
visit our website at: www.deltamachinery.com.
For Parts, Service, Warranty or other Assistance,
please call 1-800-223-7278 (In Canada call 1-800-463-3582).
Inhaltszusammenfassung zur Seite Nr. 2
SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protect- ing YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoide
Inhaltszusammenfassung zur Seite Nr. 3
ADDITIONAL SAFETY RULES FOR AIR CLEANERS FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS INJURY. DO NOTUSE THIS UNIT TO FILTER 6. SUPPORT THIS UNIT or securely clamp it to the METAL DUST. Combining wood and work surface when it is used in a portable metal dust can create an explosion or application to eliminate potential injury and/or fire hazard. This unit is intended to filter damage to the unit. non-explosive atmospheres only. 7. ENSURE THAT THE INTAKE AND EXHAUST DO NOT USE THIS UNIT TO
Inhaltszusammenfassung zur Seite Nr. 4
POWER CONNECTIONS A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3- prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the machine to the power line, make sure the switch (s) is in the “OFF” position and be sure that the electric current is of the same ch
Inhaltszusammenfassung zur Seite Nr. 5
EXTENSION CORDS MINIMUM GAUGE EXTENSION CORD RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES Ampere Total Length Gauge of Rating Volts of Cord in Feet Extension Cord Use proper extension cords. Make sure 0-6 120 up to 25 18 AWG 0-6 120 25-50 16 AWG your extension cord is in good condition and is a 3-wire 0-6 120 50-100 16 AWG extension cord which has a 3-prong grounding type 0-6 120 100-150 14 AWG plug and matching receptacle which will accept the 6-10 120 up to 25 18 AWG machine’s p
Inhaltszusammenfassung zur Seite Nr. 6
UNPACKING AND CLEANING The Air Cleaner is shipped complete in one shipping container. Carefully unpack the Air Cleaner and all loose items from the shipping container. Styrofoam blocks have been packed inside the unit for protection. REMOVE THESE BLOCKS (A) Fig. 1 prior to use. To Remove: 1. Disconnect unit from power source. 2. Remove outer filter by lifting up on the bottom and pulling out (Fig. 2A). 3. Remove inner filter by lifting up on the bottom and pulling out (Fig. 2B). 4. Remove styro
Inhaltszusammenfassung zur Seite Nr. 7
MOUNTING THE AIR CLEANER TO THE CEILING OR OVERHEAD SUPPORT This unit weighs approximately 60 pounds. When mounting overhead, be certain that the unit is securely fastened and supported. 1. Locate the four 1" eye bolts and the four 1/4-20 flange nuts supplied with the unit. 2. Use a flat blade screwdriver (not supplied) to remove the four screws (C) Fig. 5 from the top of air cleaner (D). 3. Thread one flange nut on each bolt approximately 3/4". 4. Thread the eye-bolts (F) Fig. 6 into the four h
Inhaltszusammenfassung zur Seite Nr. 8
USING THE REMOTE CONTROL C To reduce the risk of fire or electric shock, do not use this unit with any solid-state speed control device. G F B The remote control provided with this unit is not con- sidered a solid-state device. D The Air Cleaner is equipped with a REMOTE CONTROL (A) Fig.8A. J H A NOTE: The remote requires two (2) AAA batteries (not supplied). The Battery housing is located underneath the K back cover. E Notice that the remote control has three control buttons (Fig. 8A): TIME (B
Inhaltszusammenfassung zur Seite Nr. 9
Compressed air can be dangerous. For operator safety, do not exceed an air pressure of 30 psi. Do not point the air nozzle toward yourself or anyone else. Always wear safety glasses and a dust mask when using compressed air. 3. Replace the filter, turn the unit “ON”, and check the air flow indicator again. 4. If the air flow indicator points to “green”, the inner filter is still useable. If the indicator points to “red”, remove the outer filter, then remove the inner filter (B) Fig. 9C by liftin
Inhaltszusammenfassung zur Seite Nr. 10
ACCESSORIES A complete line of accessories is available from your Delta Supplier, Porter-Cable • Delta Factory Service Centers, and Delta Authorized Service Stations. Please visit our Web Site www.deltamachinery.com for a catalog or for the name of your nearest supplier. Since accessories other than those offered by Delta have not been tested with this product, use of such accessories could be hazardous. For safest operation, only Delta recommended accessories should be used with this product. P
Inhaltszusammenfassung zur Seite Nr. 11
PORTER-CABLE • DELTA SERVICE CENTERS (CENTROS DE SERVICIO DE PORTER-CABLE • DELTA) Parts and Repair Service for Porter-Cable • Delta Machinery are Available at These Locations (Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable • Delta) ARIZONA Tampa 33609 MICHIGAN Cleveland 44125 Tempe 85282 (Phoenix) 4538 W. Kennedy Boulevard Madison Heights 48071 (Detroit) 8001 Sweet Valley Drive 2400 West Southern Avenue Phone: (813) 877-9585 30475 Stephenson