Inhaltszusammenfassung zur Seite Nr. 1
EFFICIENCY
USER’S INFORMATION RATING
CERTIFIED
MANUAL
MODELS:
ISO 9001
Certified Quality
All Residential Multi-position Gas Furnaces
Management System
(33” Models)
TABLE OF CONTENTS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 How to Clean your Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 BLOWER CARE . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 2
356486-UUM-E-0109 SECTION II: INSTRUCTIONS FOR EXAMINING THE FURNACE INSTALLATION FIRE OR EXPLOSION HAZARD It is the owner’s responsibility to ensure that an annual inspection of the This furnace is designed and approved for use with Natural Gas entire heating portion of the unit is made by a qualified service agency. and (LP) Propane Gas ONLY. DO NOT BURN ANY LIQUID FUEL Examine the furnace as outlined below in steps “1 - 8” before each OR SOLID FUEL IN THIS FURNACE. heating season. Use Figur
Inhaltszusammenfassung zur Seite Nr. 3
356486-UUM-E-0109 Rollout Manifold Rollout Manifold Safety Switch Pipe Safety Switch Pipe Flame Sensor Flame Sensor Ignitor Ignitor Gas Valve Gas Valve Limit Switch Limit Switch (Behind gas valve) Vent Pipe (Behind gas valve) Vent Pipe Draft Inducer Draft Inducer Electrical Electrical Assembly Assembly Junction Box Junction Box Pressure Pressure Switch Switch Silicone Tube Silicone Tube Condensate Condensate Pan Safety Pan Safety Door Switch Door Switch Control Control Board Board Transformer Tr
Inhaltszusammenfassung zur Seite Nr. 4
356486-UUM-E-0109 OPERATING INSTRUCTIONS HIGH STAGE REGULATOR 1. STOP! Read the safety information above for your protection. ADJUSTMENT OUTLET 2. Set the thermostat to the lowest setting in the heat mode. PRESSURE PORT VENT 3. Turn off all electric power to the appliance. PORT 4. Remove furnace burner access panel/door. 5. Move gas control switch to the “OFF” position. Do not force. See INLET OUTLET Figures 8, 7 or 8. 6. Wait five (5) minutes to clear out any gas. If you then smell gas, WRENCH
Inhaltszusammenfassung zur Seite Nr. 5
356486-UUM-E-0109 Every time the external air filters are changed the following items 3. Check that the ON/OFF switch on the gas valve is turned to the should be visually inspected: ON position. Refer to Figures 8, 7 or 8. 4. Check that the furnace blower access panel/door is correctly posi- • Check combustion air and vent pipe for blockage or leakage. tioned. The electrical power supply will be cut off if this door is • Check all components to be sure they are in good condition and removed. tha
Inhaltszusammenfassung zur Seite Nr. 6
Limited Warranty UPG warrants this product to be free from defects in factory workmanship and material under normal use and service and will, at its option, repair or replace any parts that prove to have such defects according to the terms outlined on this warranty. This warranty covers only the equipment described by the Product Model Number and Serial Number listed on the Warranty Registration Card. UPG warrants the primary heat exchangers in the product to be free from defects in factory work