Inhaltszusammenfassung zur Seite Nr. 1
Operating Instructions
Air Conditioner
Model No.
Indoor Unit Single Split
Outdoor Unit
CS-E9NKUAW CU-E9NKUA
CS-E12NKUAW CU-E12NKUA
Multi Split
Outdoor Unit
CU-2E18NBU
ENGLISH
Before operating the unit, read these operating
instructions thoroughly and keep them for future
reference.
© Panasonic Appliances Air-Conditioning Malaysia
QUICK GUIDE QUICK GUIDE
Sdn. Bhd. 2012. Unauthorized copying and distribution
is a violation of law.
F568316
Inhaltszusammenfassung zur Seite Nr. 2
SAFETY PRECAUTIONS Thank you for purchasing To prevent personal injury, injury to others, or property damage, please Panasonic Air Conditioner comply with the following. Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below: T TABLE OF CONTENTS ABLE OF CONTENTS This sign warns of death or WARNING WARNING SAFETY PRECAUTIONS serious injury. 2~3 This sign warns of injury or CA CAU UTION TION MULTI AIR CONDITI
Inhaltszusammenfassung zur Seite Nr. 3
W WARNING ARNING C CA AU UTION TION REMOTE CONTROL INDOOR UNIT AND OUTDOOR UNIT Do not allow infants and small children to play Do not wash the indoor unit with water, benzene, with the remote control to prevent them from thinner or scouring powder to avoid damage or accidentally swallowing the batteries. corrosion at the unit. Do not use for preservation of precise equipment, POWER SUPPLY food, animals, plants, artwork or other objects. This Do not use a modifi ed cord, may cause quality
Inhaltszusammenfassung zur Seite Nr. 4
MULTI AIR CONDITIONER SYSTEM Multi Split Outdoor Unit (CU-2E18NBU) DEFINITION Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit. IINDOOR UNIT NDOOR UNIT • It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the fi rst unit that turned on. • During operation, heating and cooling mode can not be activated at the same time for different indoor unit. The power indicator blinks
Inhaltszusammenfassung zur Seite Nr. 5
INDOOR UNIT • Switch off the power at the circuit breaker before cleaning. • Do not touch the aluminium fi n, sharp parts may cause injury. CAUTION C CLEANING INSTRUCTIONS LEANING INSTRUCTIONS H HINT INT • Do not use benzene, thinner or scouring powder. • To ensure optimal performance of the unit, cleaning • Use only soap ( pH7) or neutral household detergent. maintenance has to be carried out at regular intervals. • Do not use water hotter than 104°F. Dirty unit may cause malfunction and you
Inhaltszusammenfassung zur Seite Nr. 6
AUTO FAN SPEED HEAT AIR COOL SWING DRY OFF/ON MODE FAN SPEED TEMP AIR SWING QUIET POWERFUL TIMER ON SET 1 2 3 OFF CANCEL AC RC SET CHECK CLOCK RESET REMOTE CONTROL Press the remote control’s button 1 TO TURN ON OR OFF THE UNIT • Please be aware of the OFF indication on the remote Maximum distance: 26ft control display to prevent the unit from starting/stopping improperly. 2 TO SET TEMPERATURE • Selection range : 60°F ~ 86°F. • Operating the unit within the recommended temperature could induc
Inhaltszusammenfassung zur Seite Nr. 7
TO REACH TEMPERATURE 7 T TO O SET THE TIMER SET THE TIMER QUICKLY • Single Split System: This operation stops automatically • To turn ON or OFF the unit at a preset time. after 20 minutes. ON • Multi Split System: Press the button again or turn OFF the unit to stop this operation. 1 2 SET Press and hold for 5 seconds to dim or restore the 8 OFF unit’s indicator brightness. Select ON or Set the time Confi rm Press and hold for approximately 10 seconds to OFF timer 9 show temperature setting i
Inhaltszusammenfassung zur Seite Nr. 8
TROUBLESHOOTING T The f he follo ollowing symptoms do not indica wing symptoms do not indicate malfunction. te malfunction. SYMPT SYMPTOM OM CA CAU USE SE Mist emerges from indoor unit. ► • Condensation effect due to cooling process. Water fl owing sound during operation. ► • Refrigerant fl ow inside the unit. The room has a peculiar odor. ► • This may be due to damp smell emitted by the wall, carpet, furniture or clothing. Indoor fan stops occasionally during automatic fan speed ► • This helps t
Inhaltszusammenfassung zur Seite Nr. 9
INFORMATION FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE NON SERVICEABLE CRITERIAS • Check remote control batteries. SWITCH OFF POWER AT THE CIRCUIT • No obstruction at air inlet and air outlet vents. BREAKER then please consult an authorized • Use Auto OFF/ON button to select Cooling/Heating operation. dealer under the following conditions: After 15 minutes of operation, it is normal to have the following • Abnormal noise during operation. temperature difference between air inlet and air o
Inhaltszusammenfassung zur Seite Nr. 10
MEMO
Inhaltszusammenfassung zur Seite Nr. 11
MEMO
Inhaltszusammenfassung zur Seite Nr. 12
QUICK GUIDE R Remote Control Preparation emote Control Preparation 1 2 Pull out 1 2 Insert AAA or R03 batteries (can be used ~ 1 year) 3 Close the cover 3 4 5 6 Press CLOCK 4 TIMER ON SET 1 3 5 Set time 2 OFF CANCEL Confi rm 6 AC RC SET CHECK CLOCK RESET 1 M MODE ODE AUTO HEAT AUTO FAN DRY COOL SPEED HEAT AIR COOL SWING Select the desired mode. DRY OFF/ON 2 MODE FAN SPEED 2 1 OFF/ON OFF/ON 3 TEMP AIR SWING Start/stop the operation. QUIET POWERFUL TIMER ON SET 1 2 3 3 OFF CANCEL TEMP TEMP AC RC Se