Inhaltszusammenfassung zur Seite Nr. 2
TABLE OF CONTENTS: Safety Instructions...............................................................................Page 3 General Information.............................................................................Page 4 Optional Components..........................................................................Page 4 Specifications......................................................................................Page 5 Roughing-in Reference.............................................
Inhaltszusammenfassung zur Seite Nr. 3
IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS! ! WARNING: Risk of personal injury. Do not permit children to use this unit without adult supervision. ! WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting. ! WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within 60 inches (1524mm) of this unit
Inhaltszusammenfassung zur Seite Nr. 4
General Installation Information Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately. After inspection and during installation, protect the bath from construction damage. Before installation, and before enclosing with wallboard, tile, etc., the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling ! Do not make modifications to the whirlpool syste
Inhaltszusammenfassung zur Seite Nr. 5
SPECIFICATIONS: L W J H C A SIDE VIEW END VIEW DRAIN / OVERFLOW B GENERAL SPECIFICATIONS FOR LIFETIME / EVOLUTION WHIRLPOOLS AND BATH TUBS Description Dimensions Drain / Height to Cut Out Rough-In Tub Edge to Weight with Product Apron / Heater Ready Gallon to Whirlpool L-W-H Overflow Underside Pier Recess Centerline Water / Floor Weight Mounting for Field Overflow Operating of Deck: C G x F E x D Overflow: J Loading Installation Volume 6060L / V 5-5/8" 824 lb. (374 kg)/ 108 lb. N/A Included L 1
Inhaltszusammenfassung zur Seite Nr. 6
ROUGHING-IN REFERENCES 5' x 32" (MODEL 2422L / V) 60" (1524mm) 13-3/4" (349mm) 3" (76mm) 32" 6" (813mm) (152mm) CUT OUT IN FLOOR FOR DRAIN 7-3/4" (197mm) PROVIDE ACCESS TO PUMP FOR 3-1/4" SERVICING (83mm) ON ALL 11" (279mm) INSTALLATIONS 6' x 36" (MODEL 7236L / V) 72" (1829mm) 11" (279mm) 3-1/4" (83mm) 13-3/4" 7-3/4" (349mm) 3" (197mm) 36" (76mm) (914mm) 6" (152mm) CUT OUT IN FLOOR FOR DRAIN PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS 5' x 36" (MODEL 2771L / V) 60" (1524mm
Inhaltszusammenfassung zur Seite Nr. 7
ROUGHING-IN REFERENCES OVAL (MODEL 2645L / V) 66" (1676mm) 11-1/4" (286mm) 1-3/4" (44mm) 18" (457mm) 36" 6" (914mm) (152mm) CUT OUT IN FLOOR FOR DRAIN PROVIDE 3" ACCESS TO (76mm) PUMP FOR 5-3/8" SERVICING 8-1/4" (137mm) ON ALL (210mm) INSTALLATIONS 5' x 32" IA-RHO (MODEL 2425L/V-RHO) - shown 5' x 32" IA-LHO (MODEL 2425L/V-LHO) 60" (1524mm) 10-1/2" (267mm) 3" 7-1/2" 2-7/8" (76mm) (73mm) (191mm) 16" (406mm) PROVIDE ACCESS 6" TO PUMP FOR (152mm) SERVICING ON ALL INSTALLATIONS 32" CUT OUT IN FLO
Inhaltszusammenfassung zur Seite Nr. 8
ROUGHING-IN REFERENCES CADET CORNER (MODEL 2775L) 229 X 305mm 1080mm (9" X 12") (42-1/2") CUTOUT IN FLOOR FOR DRAIN 1076mm (42-3/8") 1524mm 165mm (60") (6-1/2) 70mm REF. (2-3/4) PROVIDE ACCESS TO RECOMMENDED PUMP FOR FITTING SERVICING ON ALL LOCATION INSTALLATIONS 64 X 330mm PUMP (2-1/2 X 13") OUTLINE OF 279mm CUTOUT C/L (11") 1080 mm (42-1/2") C/L OF DRAIN OUTLET 2159mm ELLISSE (MODEL 2711L) (85") 1829mm (72") (36-1/2") 102mm OUTLINE OF CUTOUT 927mm (4") 1791 X 1181 (70-1/2" X 46-1/2") 305
Inhaltszusammenfassung zur Seite Nr. 9
ROUGHING-IN REFERENCES CADET 6' x 42" (MODEL 2774L) 1829mm (72") 305mm RECOMMENDED FITTING LOCATION (12") 229mm 64 X 330mm (2-1/2" x 13") (9") FOR PIER OR ISLAND 19mm INSTALLATIONS ONLY (3/4") FINISHED WALL PROVIDE ACCESS TO PUMP FOR 229mm SERVICING (9") ON ALL INSTALLATIONS 1067mm PUMP (42") CUTOUT IN FLOOR 533mm FOR DRAIN (21") OUTLINE OF 57mm (2) AIR VALVES CUTOUT (2-1/4") (8) JETS ALT. FITTING 1791mm x 1029mm LOCATION #1 (70-1/2" X 40-1/2") C/L OF DRAIN CADET 6' x 36" (MODEL 2773L) 1829
Inhaltszusammenfassung zur Seite Nr. 10
INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used as the primary access openin
Inhaltszusammenfassung zur Seite Nr. 11
TYPICAL FLANGE MOUNTING DETAIL SUGGESTED WHIRLPOOL / BATH TYPICAL INSTALLATION - INSTALLATION METHOD CORNER WOOD STUD STUDS WATERPROOF DRYWALL OR CEMENT BOARD TILE ROOFING NAIL SEALANT TUB 19-1/2 1 x 3 (25 x 76mm) WOOD (495mm) STRINGER FULL LENGTH STEEL STEEL STUD STUDS WHIRLPOOL ACCESS PANEL WASHER WATERPROOF DRYWALL OR CEMENT BOARD TILE SEALANT * SEE CUTOUT 4" (102mm) DRYWALL TEMPLATE PROVIDED SCREW TUB 1 x 3 (25 x 76mm) WOOD STRINGER FULL LENGTH UNLESS AN ACCESS OPENING OF AT LE
Inhaltszusammenfassung zur Seite Nr. 12
WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: ! 1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter. 2. Grounding is required. The unit should be installed by a licensed electrician and ground
Inhaltszusammenfassung zur Seite Nr. 13
HEATER WHIRLPOOL For 6060L/V Corner Only OPERATION Fig. 1 WARNING: Prior to operation, review the Important Safety Instructions listed at the beginning of this instruction manual. Once the heater is installed and the whirlpool pump is operating, the heater is totally automatic. The heater will help maintain the temperature of the water in the bath. HEATER “ON” LIGHT Pressure Switch FACTORY INSTALLED - NOT FOR RESALE The heater is equipped with a preset pressure switch. The pump must be Bond
Inhaltszusammenfassung zur Seite Nr. 14
OPERATION: NOTE: Each whirlpool is shipped from the factory with an air actuator on/off switch and pump with attached power supply cord. OPERATING THE SYSTEM WITHOUT WATER (DRY RUNNING) WILL CAUSE PUMP DAMAGE AND VOID THE WARRANTY. Always fill the whirlpool before operating the pump. The air switch is mounted either on the deck or side wall of the tub. 1. Fill the Whirlpool: Water level must be at least one inch (25mm) above the highest jet for proper operation. (See diagram below.) Do
Inhaltszusammenfassung zur Seite Nr. 15
Adjustable Flow Clean Jet™: The water flow action may be adjusted from vigorous to soft by rotating the nozzle counterclockwise for vigorous and clockwise for soft. NOTE: You may balance the air volume control and nozzle adjustment for the most desirable condition. Large Jet Small Jet Softer Massage Softer Massage (counter-clockwise) (counter-clockwise) More Vigorous Massage More Vigorous Massage (clockwise) (clockwise) Lifetime™ Drain Model 1599 (required on Models 7236L/V, 2422L/V, 2425
Inhaltszusammenfassung zur Seite Nr. 16
DRAIN CONNECTION AND SYSTEM TEST Using recommended drain assembly, connect whirlpool drain to waste line in accordance with the drain assembly instructions. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings are factory tightened and inspected, some loosening
Inhaltszusammenfassung zur Seite Nr. 17
AS AMERICA, INC. (AMERICAN STANDARD) LIMITED LIFETIME WARRANTY FOR LIFETIME™ / EVOLUTION™ ACRYLIC WHIRLPOOLS AS America (“American Standard”) warrants to the original consumer purchaser that it will, at its option, repair or replace this whirlpool or any of its parts that are found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser. This warranty shall only become effective upon rec