Inhaltszusammenfassung zur Seite Nr. 1
®
Model No. IMSW20701
IMSG20701
IMSB20701
USER’S MANUAL
Serial No.
The serial number can be found in the
location shown below. Write the serial
number in the space above.
Serial Number Decal
(on the frame behind the access cover)
QUESTIONS?
PLEASE CALL DIRECT TO OUR
TOLL-FREE CUSTOMER HOT
LINE. The trained technicians
on our customer hot line will
provide immediate assistance,
free of charge to you.
CUSTOMER HOT LINE:
1-877-897-7493
Mon.–Fri., 6 a.m.–6 p.m. MST
CAUTION
Visit our website at
Inhaltszusammenfassung zur Seite Nr. 2
TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 BEFORE YOU BEGIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 CHOOSING A LOCATION FOR THE RENEW 207 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 SETUP AND ASSEMBLY . . . . . . . . . . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 3
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF DROWNING, ELECTRIC SHOCK, OR SERIOUS INJURY, READ THE FOLLOWING IMPORTANT PRECAUTIONS BEFORE USING THE RENEW 207. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure 9. Do not bring any object into the RENEW 207 that all users of the RENEW 207 are adequately that could damage the spa shell. informed of all precautions. 10. Never insert any object into any opening. 2. Use the RENEW 207 only as described
Inhaltszusammenfassung zur Seite Nr. 4
20. Do not use an extension cord with the 28. DANGER—To reduce the risk of drowning: RENEW 207; this could damage the motor • Never use the RENEW 207 alone; and will void the warranty. • Children should not use the spa unless they are supervised by an adult; 21. DANGER—If you will be using the RENEW • Keep pets away from the spa at all times; 207 outside, do not bury the power cord. • Always replace and lock the spa cover Keep the power cord away from lawn mow- when the spa is not in use. ers,
Inhaltszusammenfassung zur Seite Nr. 5
34. WARNING—To reduce the risk of injury or of 35 or persons with pre-existing health drowning: Consult your physician about pos- problems, such as obesity, heart disease, sible side-effects of any medications you high or low blood pressure, circulatory prob- may be taking before using the RENEW 207. lems, or diabetes to consult their physician Heat from the water, in conjunction with some before using the RENEW 207. medications, may cause drowsiness and increase the risk of drowning. Others ca
Inhaltszusammenfassung zur Seite Nr. 6
BEFORE YOU BEGIN ® Congratulations for selecting the new IMAGE For your benefit, read this manual carefully before RENEW 207 massage spa. The RENEW 207 offers using the RENEW 207. If you have additional ques- the features and quality of a traditional hot tub at an tions, please call our Customer Service Department affordable price, providing the benefits of hydrotherapy toll-free at 1-877-897-7493, Monday through Friday, in the comfort and privacy of your home. 6 a.m. until 6 p.m. Mountain Time
Inhaltszusammenfassung zur Seite Nr. 7
CHOOSING A LOCATION FOR THE RENEW 207 There are many factors to consider when choosing a location to set up the RENEW 207. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where you want to set up the spa. If you set up the RENEW 207 inside: If you set up the RENEW 207 outside: 1. The RENEW 207 will increase the level of humidi- 1. Check your local building codes concerning the ty in your hom
Inhaltszusammenfassung zur Seite Nr. 8
SETUP AND ASSEMBLY Before beginning assembly, carefully read the • Read each assembly step before you begin. following information and instructions: • During assembly, make sure that all parts are • Place all parts of the spa in a cleared area and turned as shown in the drawings. remove the packing materials from the spa shell; do not dispose of the packing materials until TOOLS REQUIRED (not included): assembly is completed. • One Phillips screwdriver • Assembly requires two people. 1. Bef
Inhaltszusammenfassung zur Seite Nr. 9
4. Attach the nozzle of the included air pump to the 4 valve on the Insulating Liner (4). Fill the Insulating 4 Liner with air. Be careful not to overfill the Insulating Liner. Cutout Lay the Spa Cover (11) on the floor as shown. Set the Insulating Liner (4) inside the Spa Cover. Insert one of the four straps on the inside of the Spa Cover (11) through one of the loops on the Insulating Loops Liner (4). Attach the latch on the strap to the buckle Loops on the other end of the strap. Attach the
Inhaltszusammenfassung zur Seite Nr. 10
POSTING THE WARNING SIGN The included warning sign, shown below, must be posted on a wall or fence where it will be visible to all users of the RENEW 207. If the spa is moved, the sign must also be moved and reposted near the spa. If the sign becomes lost or illegible, call our toll-free Customer Hot Line at 1-877-897-7493 to obtain a free replacement sign. Post the sign as described above. USING THE RENEW 207 The RENEW 207 is designed to seat two adults. The There is a spa holds 150 gallons of
Inhaltszusammenfassung zur Seite Nr. 11
TESTING AND TREATING THE WATER USING THE CONSOLE For water maintenance, the hydrotherapy spa comes The function of each console control is explained with a starter chemical pack for maintaining the water below: in the spa. Additional chemicals can be purchased at a pool and spa supply store. Always keep the chem- icals away from children and pets. The first time you use the spa, you must test and treat Temperature Air the water. You must also treat the water each time Control Control you refill
Inhaltszusammenfassung zur Seite Nr. 12
SECURING THE SPA COVER After the spa cover is secured, you can fur- Adjustment To secure the spa cover, snap the latches on the spa ther tighten it by Flaps cover into the buckles on the side of the spa. adjusting the self- attaching flaps on To lock the buckles, each end of the spa insert the key and cover. turn it clockwise 1/4 Latch turn. To unlock the Always keep the buckles, insert the buckles locked Buckle key and turn it coun- Key when the spa is not terclockwise 1/4 turn. in use. Keep t
Inhaltszusammenfassung zur Seite Nr. 13
MAINTENANCE The RENEW 207 is designed to provide years of MAINTAINING THE SPA EXTERIOR enjoyment. Follow the guidelines below to properly maintain the spa. The surround has been treated at the factory. For information and supplies to maintain the beauty and MAINTENANCE SCHEDULE color of your surround, call our Customer Service Department toll-free at 1-877-897-7493. DAILY • Check the water level. If necessary, refill the spa to CHECKING AND CLEANING THE FILTER the level shown in step 3 on page 8
Inhaltszusammenfassung zur Seite Nr. 14
WATER CHEMISTRY REMOVING AND ATTACHING THE ACCESS COVER The hydrotherapy spa comes with a starter chemical To remove the access cover, first remove the four pack for maintaining the water in the spa. (See TEST- access cover screws. Slide the access cover down ING AND TREATING THE WATER on page 11.) and then pull the bottom of it away from the spa unit. Additional chemicals can be purchased at a pool and Be careful not to damage the spa shell as you spa supply store. remove the cover. CAUTION: Th
Inhaltszusammenfassung zur Seite Nr. 15
To drain the RENEW 207, follow these steps: WINTER USE AND CARE 1. Set the temperature control on the console to the lowest setting. The RENEW 207 is designed for year-round use. If 2. Unplug the power cord. you decide to store the spa for the winter, store it in a 3. Remove the access cover from the spa. warm, dry location. Follow the steps below to winterize 4. Remove the drainage hose from the clip and the spa. attach a garden hose to the valve on the 1. Drain the spa (see DRAINING THE RENEW
Inhaltszusammenfassung zur Seite Nr. 16
- TROUBLE SHOOTING Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time. 1. SYMPTOM: THE SPA WILL NOT OPERATE b. The pump may have a bad bearing. Contact our customer service department. If your spa is a. Check the power cord. The power cord must be no longer under warra
Inhaltszusammenfassung zur Seite Nr. 17
8. SYMPTOM: THE WATER PULSATES OR ness on the floor around the RENEW 207, the THERE IS MINIMUM WATER FLOW spa shell may have a leak. Contact your local spa and pool service provider for repairs. a. This usually occurs only when the water level is low. Add water to the level shown in step 3 on b. A clamp or seal inside the pump compartment page 8. may be loose. Check inside the pump compart- ment for excess water, and watch the pump b. The filter may be dirty. Check the filter and unit while it i
Inhaltszusammenfassung zur Seite Nr. 18
PART LIST Model No. IMSW20701, IMSG20701, IMSB20701 R0401A Key No. Qty. Description Key No. Qty. Description 1 12 Buckle Screw 32 1 Filter Cap w/O-Ring 2 6 Buckle 33 2 #10 Kep Nut 3 3 1/4” x 1.25” Bolt 34 1 Heater Assembly 4 3 Lock Washer 35 1 LCD Display 5 1 Heater Wire Harness 36 2 Rubber Isolator 6 1 Temperature/Hi Limit Probe 37 1 Thermostat Knob Assembly 38 1 Quick Mount Bracket 7 1 Console Overlay 39 1 On/Off Wire Harness 8 1 Pressure Switch 40 2 Switch Cover Screw 9 1 Control Box 41 1 Hea
Inhaltszusammenfassung zur Seite Nr. 19
EXPLODED DRAWING Model No. IMSW20701, IMSG20701, IMSB20701 R0401A 12 48 13 23 22 29 32 28 37 21 26 7 16 14 2 2 1 31 30 8 40 25 41 10 19 20 17 9 10 35 6 42 18 47 3 11 38 3 34 33 4 4 17 15 46 15 39 5 27 45 43 24 44 36 46 19
Inhaltszusammenfassung zur Seite Nr. 20
ORDERING REPLACEMENT PARTS To order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays). To help us assist you, please be prepared to give the following information when calling: • The MODEL NUMBER of the product (IMSW20701, IMSB20701, IMSG20701) ® • The NAME of the product (IMAGE RENEW 207 hydrotherapy spa) • The SERIAL NUMBER of the product (see the front cover of this manua