Inhaltszusammenfassung zur Seite Nr. 1
Installation Manual
UAIS TRANSPONDER
FA-150
SAFETY INSTRUCTIONS....................................................................................................................i
SYSTEM CONFIGURATIONS............................................................................................................. ii
EQUIPMENT LIST..............................................................................................................................iii
1. MOUNTING.......................
Inhaltszusammenfassung zur Seite Nr. 2
**00015008313 00015008313** **00015008313 00015008313**
Inhaltszusammenfassung zur Seite Nr. 3
SAFETY INSTRUCTIONS CAUTION WARNING ELECTRICAL SHOCK HAZARD Observe the following compass safe Do not open the equipment distances to prevent interference to a unless totally familiar with magnetic compass: electrical circuits and service manual. Standard Steering compass compass Only qualified personnel FA-1501 should work inside the 1.2 m 0.8 m UAIS Transponder equipment. FA-1502 0.45 m 0.3 m Turn off the power at the switchboard Monitor unit before beginning the installation.
Inhaltszusammenfassung zur Seite Nr. 4
SYSTEM CONFIGURATION Either GPS antenna VHF antenna GPS/VHF GSC-001 combined antenna GPA-017S GVA-100 Distributor unit MONITOR UNIT DB-1 FA-1502 UNIVERSAL AIS MENU ENT DISP DIM NAV STATUS PWR FA-150 12-24 VDC UAIS TRANSPONDER FA-1501 External display, NAVNET2, Pilot plug unit Sensor Alarm system PC, BEACON RECEIVER LAN Power supply PR-240 : Standard : Option : Local supply 24 VDC 100-115/ 200-230 VAC 1φ, 50/60Hz 12-24 VDC Category of the units GSC-001 Exposed to the weather GPA-017S Exp
Inhaltszusammenfassung zur Seite Nr. 5
EQUIPMENT LISTS Standard supply No. Name Type Code no. Qty Remarks 1 UAIS Transponder FA-1501 - 1 2 Monitor Unit FA-1502 - 1 GSC-001 - GPS Antenna 3 GPA-017S - 1 Select one. GPS/VHF Combined GVA-100 - MJ-A10SPF0012-050 000-150-216 1 Cable for FA-1501 CP24-00501 005-955-550 For FA-1501 For FA-1502 CP14-06001 & CP24-00400 000-041-9801 Cable MJ-A3SPF0013-0 4 Installation Materials 35 CP24-00101 005-950-730 1 For DB-1 CP24-00141 005-952-330 1 For GVA-100 For GPA-017S/ CP24-00502 00
Inhaltszusammenfassung zur Seite Nr. 6
Optional supply No. Name Type Code no. Remarks 1 Monitor unit FA-1502 - CP20-02700 004-381-1608D-FB-CV(30m)+CP20-02701 2 Antenna cable set CP20-02710 004-381-1708D-FB-CV(50m)+CP20-02701 CP24-00300 000-041-9388D-FB-CV(30m)+CP24-00301 3 Antenna cable set CP24-00310 000-041-9398D-FB-CV(50m)+CP24-00301 4 Coaxial cable TNC-PS-3D-15 000-133-670 TNC-TNC, 15m 5 Mast mount fixture CP20-01111 004-365-780 For GSC-001 Right-angle antenna 6 No.13-QA330 000-803-239For GSC-001 base L-angle ant
Inhaltszusammenfassung zur Seite Nr. 7
1. MOUNTING NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. 1.1 Antenna Units 1.1.1 GPS antenna unit Install the GPS antenna unit referring to the drawing on page D-5 or D-6 at the back of this manual. When selecting a mounting location for the antenna, keep in mind the following points. • Select a location out
Inhaltszusammenfassung zur Seite Nr. 8
How to attach the connector N-P-8DFB for cable 8D-FB-CV Outer Sheath Dimensions in millimeters. Armor Inner Sheath Shield Remove outer sheath and armor by the dimensions shown left. 50 30 Expose inner sheath and shield by the dimensions shown left. Cover with heat-shrink tubing and heat. Cut off insulator and core by 10mm. 10 30 Twist shield end. Slip on clamp nut, gasket and clamp as shown left. Clamp Clamp Gasket Nut (reddish brown) Aluminum Foil Fold back shield over clamp and trim. Trim
Inhaltszusammenfassung zur Seite Nr. 9
1.1.2 VHF antenna Location The location of the mandatory AIS VHF-antenna should be carefully considered. Digital communication is more sensitive than analog/voice communication to interference created by reflections in obstructions like masts and booms. It may be necessary to relocate the VHF radiotelephone antenna to minimize interference effects. To minimise interference effects, the following guidelines apply: • The AIS VHF antenna should be placed in an elevated position that i
Inhaltszusammenfassung zur Seite Nr. 10
Horizontal separation distance Other VHF whip antenna Whip antenna for AIS (GPS/VHF combined antenna) More than 10 m Vertical separation distance More than 2.8 m More than 0.5 m • When coaxial cable RG-10U/Y (shipyard supply) is used, attach the coaxial plug M-P-7 (dockyard supply) as shown on the next page. 4
Inhaltszusammenfassung zur Seite Nr. 11
How to attach the plug M-P-7 Lay the coaxial cable and attach an M-type plug (if necessary) to the cable as follows. 30 mm 1. Remove the sheath by 30 mm. Sheath 5 mm 2 mm 2. Bare 23 mm of the center conductor. Trim braided shield by 5 mm and tin. 3. Slide coupling ring onto cable. Conductor 4. Screw the plug assembly on the cable. Braided shield Insulator 5. Solder plug assembly to braided shield through solder holes. Solder contact sleeve to conductor. Plug assembly Contact sleeve
Inhaltszusammenfassung zur Seite Nr. 12
Mounting procedure 1. Dismount the bottom cover, cut the cable-tie inside the unit and take out the coaxial connector attached to the combined box. 2. Loosen four screws to loosen whip antenna fixture and pull out the coaxial connector coming from the combined box through the hole in the whip antenna fixture. 3. Connect the coaxial connector to the whip antenna base and wrap the junction part of the whip antenna with vulcanizing tape and then vinyl tape for waterproofing. 4. Insert th
Inhaltszusammenfassung zur Seite Nr. 13
The top of the stanchion comes into contact with the flange. Stanchion Installing distributor unit DB-1 The length of the cable between the distributor unit and transponder unit is 1 m so locate the distributor unit within 1 m from the transponder unit. Fix the distributor unit on the bulkhead, facing the cable entrance downward. Remove the lid of the distributor unit and secure the unit with two self-tapping screws. Self-tapping screw (4x30) Note: Be sure no foreign material or wat
Inhaltszusammenfassung zur Seite Nr. 14
1.2 Monitor Unit The monitor unit can be installed on a desktop or flush mounted in a panel. Install it on the chart table or near the steering place, referring to the outline drawing. When selecting a mounting location for the monitor unit, keep the following in mind: • Keep the unit out of direct sunlight. • The temperature and humidity should be moderate and stable. (Operating temperature range: -15°C to +55°C) • Locate the unit away from exhaust pipes and vents. • The mounting lo
Inhaltszusammenfassung zur Seite Nr. 15
F type Use the optional flush mount kit OP20-29. Name Type Code No. Qty Cosmetic panel 20-016-1051 100-251-370-10 1 Self-tapping screw 5x20 000-162-609-10 4 Hexagon-head bolt M6x12 000-162-897-10 2 Spring washer M6 000-158-855-10 2 1. Prepare a cutout in the mounting location whose dimensions are 183 (W) x 92 (H) mm. 2. Attach the cosmetic panel (20-016-1051) to the unit with two hex head bolts (M6x12) and two spring washers (M6). 3. Fix the unit to the mounting location with four se
Inhaltszusammenfassung zur Seite Nr. 16
1.3 UAIS Transponder Mount the transponder, where it is protected from rain and water splash. This unit can be installed on a bulkhead. Install it, referring to the outline drawing. When selecting a mounting location for the transponder, keep the following in mind: • Keep the transponder out of direct sunlight. • The temperature and humidity should be moderate and stable. (Operating temperature range: -15°C to +55°C) • Locate the unit away from exhaust pipes and vents. • The mounting
Inhaltszusammenfassung zur Seite Nr. 17
1.4 Power Supply (option) When selecting a mounting location for the unit, keep the following in mind: • Keep the unit out away from areas subject to water splash. • Locate the unit away from exhaust pipes and vents. • The mounting location should be well ventilated. • Mount the unit where shock and vibration are minimal. • A magnetic compass will be affected if the unit is placed too close to it. Observe the following compass safe distances to prevent disturbance to the magnetic compa
Inhaltszusammenfassung zur Seite Nr. 18
2. WIRING 2.1 Connection Connect the equipment, referring to the interconnection diagram at the back this manual. GPS Antenna GPS/VHF Conbined GSC-001 or Antenna GVA-100 GPS-017S 150M-W2VN or FAB-151D Either one 0.6 m Distributor unit 0.8 m DB-1 * * * RG-10U/Y Attached to Distributor RG-10U/Y (approx. 1m) : Ground is not required. 8D-FB-CV, 30 m/50 m: Option Transponder unit RG-10U/Y: Local supply FA-1501 BREAKER 6.3A VHF ANT GPS ANT PC Power Supply Ground IV-2.0sq PR-240 Monitor unit
Inhaltszusammenfassung zur Seite Nr. 19
EXT ALM: Connect ship's alarm system. DISP: Connect the monitor unit. COM1 COM2 DC (-) COM3 COM4 DC (+) COM5 COM6 Internal ports of the Transponder COM1: Long range communication device (Inmarsat C, etc.) or External display (Radar, ECDIS, Pilot plug) COM2 & COM3: External display, NAVNET 2, Pilot plug COM4-COM6: GPS, Gyrocompass, Speedlog, ROT, etc. Note: A plastic sheet is placed across the cable glands of the transponder to keep out foreign material. Cut out holes in the plasti
Inhaltszusammenfassung zur Seite Nr. 20
*: Waterproofing connectors Wrap connector with vulcanizing tape and then vinyl tape. Bind the tape end with a cable-tie. Waterproofing connector **: DPYC-2.5, TTYCS-1Q and TTYCS-4 are Japan Industry Standard cables. Use them or the equivalents. DPYC-2.5 TTYCS-1Q (Four core twisted) Armor Armor Sheath Sheath φ = 12.8 mm Shield φ = 11.3 mm Conductor Conductor 2 S = 2.5 mm 2 S = 0.75 mm φ = 2.01 mm φ = 1.11 mm TTYCS-4 (Four twisted pairs) φ = 16.3 mm Armor Sheath Shield Conducto