Inhaltszusammenfassung zur Seite Nr. 1
GPIB-XHR
GPIB-XFR
GPIB-XFR3
Operating Manual
Internal GPIB Interface
for XHR/XFR Series
Programmable DC
Power Supplies
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
Operating Manual for Internal GPIB Interface for XHR 1000 Watt Series, XFR 1200 Watt Series and XFR 2800 Watt Series Programmable DC Power Supplies
Inhaltszusammenfassung zur Seite Nr. 4
Limited What does this warranty cover and how long does it last? Warranty This Limited Warranty is provided by Xantrex Technology, Inc. (“Xantrex”) and covers defects in workmanship and materials in your GPIB Interface Card. This warranty lasts for a Warranty Period of 5 years from the date of purchase at point of sale to you, the original end user customer. What will Xantrex do? Xantrex will, at its option, repair or replace the defective product free of charge, provided that you notify Xa
Inhaltszusammenfassung zur Seite Nr. 5
Direct returns may be performed according to the Xantrex Return Material Authorization Policy described in your product manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repaired at one of these facilities. In any warranty claim, dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantre
Inhaltszusammenfassung zur Seite Nr. 6
Disclaimer Product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND LIABILITIES, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT, HOWEVER ARISING (WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES OF MANUFACTURER’S LIABILITY, OPERATION OF LAW, CONDUCT, STATEMENT OR OTHERWISE),
Inhaltszusammenfassung zur Seite Nr. 7
Information WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS SPECIFICALLY AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN MANUALS OR OTHER DOCUMENTATION PROVIDED BY IT IN CONNECTION WITH THE PRODUCT; AND b. ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE
Inhaltszusammenfassung zur Seite Nr. 8
Power Supply WARNING—High Energy and High Voltage Exercise caution when using and calibrating a power supply. High energy levels Safety can be stored at the output voltage terminals on a power supply in normal operation. In addition, potentially lethal voltages exist in the power circuit and on the output and sense connectors of a power supply with a rated output greater than 40 V. Filter capacitors store potentially dangerous energy for some time after power is removed. CAUTION ! Operate t
Inhaltszusammenfassung zur Seite Nr. 9
About This Manual This technical manual is for the internal GPIB interface, a microprocessor-controlled option card for XHR Series and XFR Series DC output power supplies. This manual provides you with descriptions and specifications, user options, and configuration instructions, in addition to a command set which enables you to manage the power supply from an external source. Error messages and calibration procedures are also included. This manual is designed for the user who is familiar w
Inhaltszusammenfassung zur Seite Nr. 10
About This Manual viii Operating Manual for GPIB for XHR/XFR Series Power Supply
Inhaltszusammenfassung zur Seite Nr. 11
Contents About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Section 1. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Features and Features and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inhaltszusammenfassung zur Seite Nr. 12
Contents Command Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Accumulated Status, Status, and Fault Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Diagnostic LEDs
Inhaltszusammenfassung zur Seite Nr. 13
Section 1. Features and Specifications Description The internal GPIB interface card allows you to operate your power supply from a computer controller via the IEEE-488 communications bus. See Figure 1.1, “Sample Configuration using GPIB Interface”. The GPIB interface allows complete remote programming of your power supply, including status reporting, settings query, and interrupt generation with user-designated fault conditions. Both the voltage and current output are precisely programmed d
Inhaltszusammenfassung zur Seite Nr. 14
Features and Specifications Features and Functions Features and Functions Features • 16-bit programming and readback of voltage and current • Programmable soft limits for voltage and current • Programmable over voltage protection with reset • Easy-to-use, self-documenting command set • Isolated user-programmable signals such as fault, polarity, isolation, and auxiliary signals • LED status signals: error, addressed, service request, over voltage protection, and remote operation • Foldback in C
Inhaltszusammenfassung zur Seite Nr. 15
Features and Specifications Specifications Specifications The specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All specifications are subject to change without notice. Table 1.1 Specifications for XFR 1200 W Series Supply with GPIB Interface Installed (7.5 V to 40 V) Models 7.5-140 12-100 20-60 35-35 40-30 Program Resolution Voltage 1.16mV 1.8mV 3.08mV 5.4mV 6.2mV Current 19.6mA 14mA 8.4mA 5.4mA 4.2mA OVP 1.16mV 1.8mV 3.08mV 5.4mV 6.2mV 1 Program Accuracy
Inhaltszusammenfassung zur Seite Nr. 16
Features and Specifications Specifications Table 1.2 Specifications for XFR 1200 W Series Supply with GPIB Interface Installed (60 V to 600 V) Models 60-20 100-12 150-8 300-4 600-2 Program Resolution Voltage 9.2mV 15.4mV 23.1mV 46.2mV 92.4mV Current 2.8mA 1.68mA 1.12mA 0.56mA 0.28mA OVP 9.2mV 15.4mV 23.1mV 46.2mV 92.4mV 1 Program Accuracy Voltage 150mV 150mV 225mV 225mV 250mV ±0.25% ±0.35% ±0.35% ±0.35% ±0.35% Current 120mA 80mA 80mA 80mA 50mA ±0.1% ±0.1% ±0.1% ±0.1% ±0.1% OVP 600mV 800mV 1.5V
Inhaltszusammenfassung zur Seite Nr. 17
Features and Specifications Specifications Table 1.3 Specifications for XFR 2800 W Series Supply with GPIB Interface Installed (7.5 V to 40 V) Models 7.5-300 12-220 20-130 33-85 40-70 Program Resolution Voltage 1.16mV 1.8mV 3.08mV 5.1mV 6.2mV Current 42.0mA 30.8mA 18.2mA 13.0mA 9.8mA OVP 1.16mV 1.8mV 3.08mV 5.1mV 6.2mV 1 Program Accuracy Voltage 10mV 50mV 75mV 75mV 75mV ±0.12% ±0.12% ±0.12% ±0.3% ±0.3% Current 900mA 750mA 500mA 425mA 350mA ±0.1% ±0.1% ±0.1% ±0.1% ±0.1% OVP 80mV 150mV 200mV 330m
Inhaltszusammenfassung zur Seite Nr. 18
Features and Specifications Specifications Table 1.4 Specifications for XFR 2800 W Series Supply with GPIB Interface Installed (60 V to 600 V) Models 60-46 100-28 150-18 300-9 600-4 Program Resolution Voltage 9.2mV 15.4mV 23.1mV 46.2mV 92.4mV Current 6.44mA 3.92mA 2.52mA 1.26mA 0.56mA OVP 9.2mV 15.4mV 23.1mV 46.2mV 92.4mV 1 Program Accuracy Voltage 150mV 150mV 225mV 225mV 250mV ±0.25% ±0.35% ±0.35% ±0.35% ±0.35% Current 250mA 140mA 120mA 80mA 80mA ±0.1% ±0.15% ±0.1% ±0.1% ±0.1% OVP 600mV 800mV
Inhaltszusammenfassung zur Seite Nr. 19
Features and Specifications Specifications Table 1.5 Specifications for XHR 1000 W Series Supply with GPIB Interface Installed (7.5 V to 60 V) Models 7.5-130 20-50 33-33 40-25 60-18 Program Resolution Voltage 1.16mV 1.8mV 3.08mV 6.2mV 9.2mV Current 42.0mA 30.8mA 18.2mA 9.8mA 6.44mA OVP 1.16mV 1.8mV 3.08mV 6.2mV 9.2mV 1 Program Accuracy Voltage 10mV 50mV 75mV 75mV 150mV ±0.12% ±0.12% ±0.12% ±0.3% ±0.25% Current 900mA 750mA 500mA 350mA 250mA ±0.1% ±0.1% ±0.1% ±0.1% ±0.1% OVP 80mV 150mV 200mV 400m
Inhaltszusammenfassung zur Seite Nr. 20
Features and Specifications Specifications Table 1.6 Specifications for XHR 1000 W Series Supply with GPIB Interface Installed (100 V to 600 V) Models 100-10 150-7 300-3.5 600-1.7 Program Resolution Voltage 15.4mV 23.1mV 46.2mV 92.4mV Current 3.92mA 2.52mA 1.26mA 0.56mA OVP 15.4mV 23.1mV 46.2mV 92.4mV 1 Program Accuracy Voltage 150mV 225mV 225mV 250mV ±0.35% ±0.35% ±0.35% ±0.35% Current 140mA 120mA 80mA 80mA ±0.15% ±0.1% ±0.1% ±0.1% OVP 800mV 1.5V 3.0V 6V Readback Resolution Voltage 15.4mV 23.1