Generators
GENERATOR SET
6.5 HP - RECOIL START - 2600W/2800W RATED
Model 91523
OPERATING INSTRUCTIONS
®
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Website at: http://www.harborfreight.com
TO PREVENT SERIOUS INJURY,
READ AND UNDERSTAND ALL WARNINGS
AND INSTRUCTIONS BEFORE USE.
© ®
Copyright 2004 by Harbor Freight Tools . All rights reserved. No portion of this
manual or any artwork contained herein may be reproduced in any shape or form
without the express written consent of Harbor
Inhaltszusammenfassung zur Seite Nr. 2
PRODUCT SPECIFICATIONS Item Description VAC Current Output: 110/120 Volts @ 20 AMP’s Electrical Requirements 60 Hz Continuous/Rated Wattage: 2600 Peak Wattage: 2800 Two 110/120 VAC, 3-Prong Grounding Outlets One 23 AMP Circuit Breaker VDC Current Output: 12 VDC @ 10 AMP’s Electrical Requirements Voltmeter Equipped 0-150 Volts (50 Volt Increments) Display Lights Red (Run) Gasoline Engine 6.5 / Unleaded Gasoline Powered / Recoil Start 3600 RPM / 4-Cycle / OHV Air Cooled 196 CC Displac
Inhaltszusammenfassung zur Seite Nr. 3
GENERAL SAFETY RULES WARNING! READ AND UNDERSTAND ALL INSTRUCTIONS Failure to follow all instructions listed below may result in electric shock, fire, and/or serious injury. SAVE THESE INSTRUCTIONS WORK AREA 1. Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. 2. Do not operate power tools in explosive atmospheres, such as in the pres- ence of flammable liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes. 3. Keep bystan
Inhaltszusammenfassung zur Seite Nr. 4
7. Do not expose Generator to rain or wet conditions. Water entering a generator will increase the risk of electric shock. 8. Do not abuse the Power Cord. Keep Power Cords away from heat, oil, sharp edges, or moving parts. Replace damaged Power Cords immediately. Dam- aged Power Cords increase the risk of electric shock. 9. When operating a power tool outside, use an outdoor extension cord marked “W-A” or “W”. These extension cords are rated for outdoor use, and reduce the risk of electric
Inhaltszusammenfassung zur Seite Nr. 5
GENERATOR USE AND CARE 18. Make sure the Power Switch is in its “OFF” position and disconnect the spark plug wire before making any adjustments, changing accessories, or storing the generator. Such preventive safety measures reduce the risk of starting the generator accidentally. 19. Store idle generators out of reach of children and other untrained persons. Generators are dangerous in the hands of untrained users. 20. Maintain generators with care. Do not use a damaged generator. Tag dam- ag
Inhaltszusammenfassung zur Seite Nr. 6
SPECIFIC PRODUCT WARNINGS AND PRECAUTIONS HEART PACEMAKER PRECAUTION WARNING! People with pacemakers should consult their physician(s) before using this product. Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker. INSTALLATION PRECAUTIONS 1. Ensure installation meets all applicable safety, and local and national electrical codes. Have installation performed by a qualified, licensed electrician and building contractor
Inhaltszusammenfassung zur Seite Nr. 7
9. The supporting floor/ground surface should be level, and strong enough to safely hold the weight of the Generator. If the floor/ground surface is not level, strong cross members should be placed under the full length of the Generator Frame at its low side. 10. For trailer installation, the Generator should be mounted on the center point of the trailer, over the wheels. The trailer must be capable of supporting the weight of the Generator and all contents (tools, etc.) 11. Install sound- and
Inhaltszusammenfassung zur Seite Nr. 8
MECHANICAL PRECAUTIONS 1. ALWAYS make sure the Power Switch is in its “OFF” position. Disconnect the spark plug wire, and allow the Engine to completely cool before carrying out maintenance. 2. Check for damaged parts. Before using the Generator, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment and binding of moving parts, any broken parts or mounting fixtures, and any other condition th
Inhaltszusammenfassung zur Seite Nr. 9
NOISE PRECAUTIONS 1. Prolonged exposure to noise levels above 85 dBA is hazardous to hearing. Always wear ANSI approved ear protection when operating or working around the Generator when it is running. ELECTRICAL PRECAUTIONS 1. All connections and conduits from the Generator to the load must only be in- stalled by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable. 2. The Generato
Inhaltszusammenfassung zur Seite Nr. 10
8. Keep all electrical equipment clean and dry. Replace any wiring where the insu- lation is cracked, cut, abraded or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight. 9. Insulate all connections and disconnected wires. 10. Guard against electric shock. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures. INSTALLATION 1. NOTE: Prior to powering tools and equipment, make sure the
Inhaltszusammenfassung zur Seite Nr. 11
5. Place the Generator as close as possible to the electrical tools and equipment being powered to reduce the length of extension cords. 6. If the Generator in located indoors the Engine exhaust must be ventilated to the outdoors using leak-proof, heat resistant, flexible, metal, flex tubing. GENERATOR SUPPORT AND MOUNTING 1. Mount the Generator on a concrete slab capable of supporting the weight of the Generator. The slab must extend on all sides beyond the Frame (41) by at least one foot. Co
Inhaltszusammenfassung zur Seite Nr. 12
ENGINE POWER SWITCH (2) GROUND CONNECTOR (8) #6AWG GROUNDING WIRE (NOT INCLUDED) GROUNDING ROD (NOT INCLUDED) FIGURE B FUEL GAUGE (34) FUEL TANK CAP (33) FUEL T ANK (30) OIL DIPSTICK (65A) FIGURE C SKU 91523 PAGE 12
Inhaltszusammenfassung zur Seite Nr. 13
3. Before the first use, remove the Fuel Tank Cap (33) and fill the Fuel Tank (30) with nleaded gasoline. Then, replace the Fuel Tank Cap. Thereafter, check the Engine’s Fuel Gauge (34) for the amount of unleaded gasoline in the Fuel Tank. If necessary, refill the Fuel Tank with unleaded gasoline; the Generator must be turned off and cooled down before refilling the fuel tank. (See Figure C.) To Start The Engine: 1. Make sure the electrical powered tools/equipment that will be used are not pl
Inhaltszusammenfassung zur Seite Nr. 14
5. Turn the Engine Power Switch (2) to its “ON” position. (See Figure F.) ENGINE POWER SWITCH (2) ON OFF FIGURE F 6. Hold the Start Handle (41A) loosely and pull it slowly several times to allow the gasoline to flow into the Engine’s carburetor. Then hold the Start Handle firmly and pull the rope hard and fast. Pull the rope all the way out, using two hands if FUEL TANK (32) necessary. If necessary pull the rope several times until the Engine starts. (See Figure G.) 7. Allow the Engine to ru
Inhaltszusammenfassung zur Seite Nr. 15
Powering 120 Volt AC Tools And Equipment: 1. Prior to powering tools and equipment, make sure the Generator’s rated voltage, and amperage capacity (110/120VAC @ 20 AMPs) is adequate to supply all electrical loads that the unit will power. If powering exceeds the Generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator. CAUTION: THIS GENERATOR IS NOT INTENDED TO POWER SENSITIVE ELECTRONIC EQUIPMENT (INCLUDING MEDICAL EQ
Inhaltszusammenfassung zur Seite Nr. 16
3. If using only a 12 volt DC tool or equipment, turn the 110/120 volt AC Circuit Breaker (5) to its “OFF” position. (See Figure D.) 4. Start and run the Engine as previously discussed in this manual. 5. When finished using the Generator, turn the Engine Power Switch (2) to its “OFF” position. Turn the Fuel Valve (40) to its “OFF” position. Then, disconnect the electrical powered tools’ power cord from the Generator’s DC Terminals (7). (See Figure H.) 6. After the Engine and Generator have co
Inhaltszusammenfassung zur Seite Nr. 17
INSPECTION, CLEANING, AND MAINTENANCE 1. CAUTION! Always make sure the Engine Power Switch (2) is in its “OFF” position. Disconnect the spark plug wire from the engine. And allow suffi- cient time for the Engine and Generator to completely cool before perform- ing any inspection, maintenance, or cleaning. 2. Before each use, inspect the general condition of the Generator. Check for loose screws, misalignment or binding of moving parts, cracked or broken parts, damaged electrical wiring, and
Inhaltszusammenfassung zur Seite Nr. 18
PARTS LIST Part # Description Qty. Part # Description Qty. 1 Bolt w/Lock Washer (M6 x 12) 9 22 Bolt (M6 x 172) 4 2 Engine Power Switch 1 23 Bolt (M5x20) 4 3 Control Panel 1 24 Connection Board 1 4 Voltmeter 1 25 Nut (M5) 4 5 Circuit Breaker 1 26 Stator 1 6 Outlet 2 27 Rotor 1 7 DC Terminal 2 28 Cooling Fan 1 8 Ground Connector 1 29 Heat Insulation Board 1 9 DC Fuse 1 30 Fuel Tank 1 10 Pilot Light 1 31 Fuel Filter 1 11 Shock Absorber 4 32 Seal Ring 1 12 Shock Absorber Foot 4 33 Fuel T
Inhaltszusammenfassung zur Seite Nr. 19
Inhaltszusammenfassung zur Seite Nr. 20
PARTS LIST A Part # Description Qty. Part # Description Qty. 1A Muffler 1 42A Starting Case Assy. 1 2A Cylinder Head Bolt 4 43A Spiral Spring 1 3A Cylinder Head Cover Bolt 4 44A Starting Wheel 1 4A Cylinder Head Cover 1 45A Circlip 1 5A Lock Nut 2 46A Starting Ratchet 2 6A Adjusting Screw 2 47A Friction Plate Screw 1 7A Rocker Arm 3 48A Cover 1 8A Rocker Arm Bolt 2 49A Starter Pulley 1 9A Valve Push Rod Guiding Board 1 50A Cooling Fan 1 10A Valve Push Rod 2 51A Flywheel Magneto 1 11A