Inhaltszusammenfassung zur Seite Nr. 1
Coway Air Purifier AP-1008BH/CH
· This product is for domestic use only.It cannot be used in an overseas
country where the power voltage is different.
· Warranty card is included in this user’s manual.
· Read and save these instructions
Inhaltszusammenfassung zur Seite Nr. 2
FEATURES TM 1. A3 medium filter TM A3 medium filter exhibits an effective antimicrobial activity for TM removing the medium dust and the gases. A3 medium filter can be cleaned by using the vacuum cleaner and it keeps the antimicrobial activity after the cleaning. TM TM A3 medium filter A3 medium filter TM ∗ A3 : Anti-bacterial , Anti-order, Anti-dust 2. Pollution level indicator/ mood lamp It has the function showing in the pollution level indicator by sensing the pollution of the
Inhaltszusammenfassung zur Seite Nr. 3
FEATURES CONTENTS C O DEAR CUSTOMERS W A Y Thank you for using the coway air purifier. Please read the user’s manual to use and maintain the product correctly. If you encounter a problem while using the product, you may easily solve the problem by referring to the user’s manual. As this manual contains the product warranty card, please keep it in a safe place. / CONTENTS For Information How to Use SAFETY INFORMATION ………………… 03 PREPARATIONS …………………………… 09 - Electricity Safety …………………………
Inhaltszusammenfassung zur Seite Nr. 4
SAFETY INFORMATION The following information is for user safety that should be observed. It is to ensure user safety and prevent property damage. Please read the precautions carefully and use the product correctly. If not observed, serious physical If not observed, serious physical If not observed, minor physical injury or property damage may injury or property damage may injury or property damage may Danger occur as a result. Warning occur as a result. Caution occur as a result. Electricity S
Inhaltszusammenfassung zur Seite Nr. 5
For Information SAFETY INFORMATION I Electricity Safety I Installation Safety Danger Warning Caution Remove any dust or water Do not plug into an electric outlet or power strip that is from the power plug. being used by several other Otherwise electric shock or fire may occur as a result. appliances. Use an electric outlet dedicated to the product. Otherwise fire may occur as a result. Unplug the product if it is not Do not attempt to repair to be used for a long time. or
Inhaltszusammenfassung zur Seite Nr. 6
SAFETY INFORMATION When the product is in use, Install the product where no maintain a distance of at least obstacles around the product 20 cm from walls or adjacent block the circulation of air. objects and 30 cm - 60 cm above the product. Otherwise walls, ceilings, or surrounding objects may be contaminated. Use the air purifier away Install the air purifier at least from lighting devices or 2 m away from electronic direct sunlight. products such as tv. Otherwise operatio
Inhaltszusammenfassung zur Seite Nr. 7
For Information SAFETY INFORMATION I Installation Safety I Operation Safety Danger Warning Caution Unplug the product before Do not clean the product by you clean it. applying water directly to the product or using benzene or Otherwise electric shock or fire may thinner. occur as a result. Otherwise electric shock or fire may occur as a result. Do not stick fingers or foreign Do not let children hang on to objects into the air inlet or the product or climb on it. outlet. Ot
Inhaltszusammenfassung zur Seite Nr. 8
PARTS NAME Front Rear < AP-1008BH/CH > Display part/ operation part Pollution level indicator/ mood lamp Air outlet Pollution sensor unit Handle Filter replacement reset button Power cord Others User’s manual 7
Inhaltszusammenfassung zur Seite Nr. 9
For Information PARTS NAME AIR PURIFIED PROCESS AIR PURIFIED PROCESS ■ Pre-filter Treated with antibacterial materials, the pre-filter removes relatively large dust, mold, human hair, pet hair, and others. TM ■ A3 medium filter TM A3 medium filter removes the medium dust and the gases, and it prevents the HEPA filter. TM A3 medium filter is antimicrobial and can be cleaned by using the vacuum cleaner, TM and the A3 medium filter keeps its antimicrobial activity after the
Inhaltszusammenfassung zur Seite Nr. 10
PREPARATIONS Please Check Before Use! ~ The product is for 120 V 60 Hz only. Make sure to connect the power plug to a grounded ~ electric outlet (120 V 60 Hz) dedicated to the product. How to install filter - Make sure to remove each filter’s plastic packing before installing filters. - The product is for household use. Use the product indoors only. - When the product is not in use, remove the power plug from the electric outlet. Tips - When installing filters, check that the front side
Inhaltszusammenfassung zur Seite Nr. 11
How to Use PREPARATIONS OPERATION/INDICATION PART OPERATION / INDICATION PART Indication Part 1 2 / 1 Light sensor It is a sensor that detects light. 2 Speed indicator By using the speed button, it is possible to select the airflow speed in 4 steps (Step 1 → Step 2 → Step 3 → Turbo) ∗ When the product is in sleep mode and power saving mode, the ai rflow speed indicators are not turned on. 10
Inhaltszusammenfassung zur Seite Nr. 12
OPERATION / INDICATION PART Operation Part 1 2 5 4 3 2 1 Auto mode button and its Power button and its indicator indicator Use it to turn the product Use it to select the automatic on/off. When the power operation mode. When the auto is on, the indicator is turned on. mode is selected, the indicator is ∗ To turn off the power, press and hold the turned on. power button for approximately 1 second. 3 4 Mood button and its Silent mode button and its indicator indicator Use it to turn
Inhaltszusammenfassung zur Seite Nr. 13
How to Use OPERATION/INDICATION PART It displays the current cleanliness (pollution) level of the room. Clean:Blue Lightly polluted: Polluted: Highly Light purple Dark purple polluted : Red ∗ The cleanliness (pollution) level of the room is determined by the color at the end of the penetrating hole. 12
Inhaltszusammenfassung zur Seite Nr. 14
HOW TO USE - Before operating the product, connect the power plug to a dedicated electric outlet. - Once the power is turned on, you will see the previously used operation mode, Tips already set for you to use. ■ To operate the manual mode Press the power button and then select the speed of the wind by pressing the speed button. ▶ ■ To select the auto mode Press the power button and then select the auto mode button. ▶ ▶ Auto mode Auto operating mode sets the wind speeds (step 1, 2, or
Inhaltszusammenfassung zur Seite Nr. 15
How to Use HOW TO USE ■ To operate the silent mode Press the power button and then the silent button. In silent mode, the airflow speed is lowered below step 1 (lower rpm), ▶ making the environment quiet and pleasant. ■ To operate the sleep mode(available only in auto mode operation) If the surroundings are dark for 3 minutes or longer in auto mode operation, the product automatically switches to sleep mode, lowering the airflow speed, noise, and electricity consumption.If the surro
Inhaltszusammenfassung zur Seite Nr. 16
ADJUST PARTICLE SENSOR How to Adjust the Sensitivity of the Pollution Sensor When the product is shipped out, the pollution sensor is set to standard sensitivity. If the pollution level stays at the highest level after 2 hours of operation or stays at the lowest level for more than 1 hour when the air does not seem clean, users can adjust the sensitivity of the pollution sensor as follows. 1. With the mood mode button pressed down, insert the power plug in the electric outlet. 2. With a t
Inhaltszusammenfassung zur Seite Nr. 17
How to Use ADJUST PARTICLE SENSOR CLEANING METHOD ADJUST PARTICLE SENSOR CLEANING METHOD - Always unplug the air purifier before cleaning the product. - Do not use detergents that contain organic solvents (solvent, thinner, etc), bleach, chlorine, or abrasives. Tips - Do not put the air purifier in water or spray water directly on it. ■ Cleaning the pollution sensor (every 2 months) Air outlet 1. Open the pollution sensor cover on the right-hand side of the product. Clean the air inl
Inhaltszusammenfassung zur Seite Nr. 18
CLEANING METHOD - Always unplug the product before cleaning the filter. - The pre-filter is reusable by removing dust or cleaning it with water. - If the pre-filter is not cleaned for a long time, the product performance may deteriorate. Tips - The HPEA filter are not reusable with cleaning. Never clean them with water. ■ Cleaning the pre-filter (every 2 ~ 4 weeks) 1. Open the front cover by pulling out the end part above the air inlet. 2. Take out the pre-filter by pulling out on the hand
Inhaltszusammenfassung zur Seite Nr. 19
Maintenance CLEANING METHOD FILTER REPLACEMENT FILTER REPLACEMENT ■ How to replace filters - Check that the ‘front’ sides of filters are in the correct direction. - To maintain optimal performance of the product, use original coway filters. - Always unplug the air purifier before replacing filters. ■ Filter cleaning and replacement cycles Filter cycles method Pre-filter Every 2~4 weeks Cleaning Every 4 months Cleaning TM A3 medium filter Every 30 months Replacement / HEPA filter Every 30
Inhaltszusammenfassung zur Seite Nr. 20
TROUBLESHOOTING The air purifier may operate abnormally not because of the product malfunction but because of minor causes or the fact that the user is not familiar with the product use. In such a case, problems can be solved easily even without the help from the service center just by checking the following. If the problem still persists after you check the following, contact the service center. Symptom Check Measures to take Connect the power cord to an electric • Is the power cord connec