Inhaltszusammenfassung zur Seite Nr. 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
EG40 DV
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
WHAT TO DO IF YOU SMELL GAS
• Open windows/Extinguish any open flame.
• Do not try to light any appliance.
• Do not touch any electrical switch or use any
phone in your building.
• Immediately call your gas supplier from a
neighbour’s phone. Follow the gas supplier’s
i
Inhaltszusammenfassung zur Seite Nr. 2
Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, do not allow anyone who is in accordance with their instructions. Carefully read all unfamiliar with the stove to operate it. the instructions in this manual first. Consult the building • To prevent injury, if the pilot or pilot and authority having jurisdiction to determine the need for burn
Inhaltszusammenfassung zur Seite Nr. 3
Table of Contents Safety Precautions...............................................................................2 Table of Contents.................................................................................3 Codes And Approvals...........................................................................4 Specifications......................................................................................5 Dimensions...........................................................................
Inhaltszusammenfassung zur Seite Nr. 4
Codes And Approvals DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 ft to 4500 ft (1372 m) above sea level. In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliance
Inhaltszusammenfassung zur Seite Nr. 5
Specifications DIMENSIONS: 1 12 / 2 " ( 31 8 m m ) 5 4 / 8 " ( 1 1 7 m m ) 2 1 " ( 53 3 m m ) 1 2 9 / 8 " ( 7 40 m m ) 25 " ( 6 35 m m ) S h i p pi n g W e i g h t 25 6 l b s ( 1 1 6 kg ) Figure 1: EG40 Exterior Dimensions. RATING LABEL LOCATION: The rating label is found inside the right cabinet side panel. 5
Inhaltszusammenfassung zur Seite Nr. 6
L O I P T O L T P T H T P T H I P F F Operating Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. LIGHTING INSTRUCTIONS: C A U T I O N : H o t wh ile o p er at i n g . D o n o t t o u ch , s eve r e b u r n s m ay r esu l t . K e e p ch i ld re n , c l o t h i n g , f u r n i t u r e, g aso l i n e o r o t h e r f la m m ab l e vap o r s aw a y . C A U T I O N : D o n o t o p e r at e th i s f i r e pl a ce w i t h t he g l as s r e m o v ed, c r a c ke d o r b r ok e n. R ep l a c
Inhaltszusammenfassung zur Seite Nr. 7
Operating Instructions T h e r m o p i l e T h e r m o c o u p l e Figure 3: Pilot Burning. Figure 4: Gas Valve. ADJUSTING THE VENTURIES: • There is a separate venturies for each burner, R e ar l o g h o l d er see Figure 5. F ro n t lo g h ol der E m be r t r ay & • Remove one screw from the cover plate located R ea r b u r n er f r o nt b ur n er below the ash shelf and loosen the other screw D o o r (do not remove) swing the cover plate out of the way and tighten screw down to hold it in
Inhaltszusammenfassung zur Seite Nr. 8
Maintenance and Service Annually check to ensure that your Venting system is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with no or very small yellow tips. OPENING THE DOOR: Turn unit off and wait until the appliance has cooled down. 1. Open the right hand hinged side flap, which will expose a door fastener. Using a 1⁄2” wrench, loosen the fastener. 2.
Inhaltszusammenfassung zur Seite Nr. 9
Maintenance and Service 3. Vacuum the bottom of the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burner and pilot burner. 4. After carefully replacing the log and embers in their correct positions (see Secondary Installation - Installation of Log Set and Embers), and the door has been resealed, re-light the pilot, following the instructions on the lighting label attached to the unit. CLEANING PLATED SURFACES: It is important to note that finge
Inhaltszusammenfassung zur Seite Nr. 10
Maintenance And Service FUEL CONVERSION: TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result c
Inhaltszusammenfassung zur Seite Nr. 11
Maintenance And Service 7. Convert the SIT gas valve: a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 9. 5 b) Insert a /32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 10), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt. L o o s e n T i g h t e n d) Flip the screw (refer to Figure 11). e) Using the Allen wrench as shown in Figure 10, rotate the screw clockw
Inhaltszusammenfassung zur Seite Nr. 12
Initial Installation QUALIFIED INSTALLERS ONLY WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. PREPARATION FOR INSTALLATION: • Remove the packaging from the appliance, and check to make sure there is no damage. If damage is found, please report it to both the carrier and your dealer as soon as possible. • Before beginning, carefully check the glass door and the log set
Inhaltszusammenfassung zur Seite Nr. 13
Initial Installation QUALIFIED INSTALLERS ONLY PLANNING YOUR INSTALLATION: When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10 inches (25.4 cm), 11⁄2 inches (3.8 cm) clearance to combustibles must be maintained. Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine the le
Inhaltszusammenfassung zur Seite Nr. 14
Initial Installation QUALIFIED INSTALLERS ONLY CORNER INSTALLATIONS: O u t s i d e o r Do not interfere with the structural integrity of I n s i d e W a l l O u t s i d e W a l l the walls. Figure 16: Corner installation top vented. MOBILE HOME INSTALLATION: • When the unit is installed in a Mobile Home it must be grounded to the steel chassis or connected to a grounding rod. • In a Mobile Home installation the unit must be bolted securely to the floor using the holes provided (see Figure
Inhaltszusammenfassung zur Seite Nr. 15
Initial Installation QUALIFIED INSTALLERS ONLY VENT TERMINATION RESTRICTIONS: N O H D E B C B F i x e d B G C l os e d L F i x e d O pe n a b l e F Cl ose d G O p e na b l e M J K B A I A Te r m i na t i o n C a p A i r S u p p l y I nl e t R e s tr i cti o n Z o n e G G a s M e te r ( T e r m i na t i o n n o t a l l o w e d ) Figure 18. Vent Termination Restrictions, refer to Table 2. Table 2: Vent termination clearances, refer to Figure 18. 1 2 Letter Canadian Installation US Installation De
Inhaltszusammenfassung zur Seite Nr. 16
Initial Installation QUALIFIED INSTALLERS ONLY FREESTANDING DIRECT VENT KIT WITH COUPLER: KIT COMPONENTS: Quantity Description Quantity Description 1 Horizontal direct vent termination cap 1 Wall Thimble 2 Flue collar adapters (only one used) 4 Wire spacers 4 T-20 Torx screws 3 Decorative rings 1 Ø65⁄8” (17 cm) 90° elbow 1 4 oz tube RTV silicone 9 1 Inside finish trim collar 20 /16” tech screws 1 5’ (190cm) length of Ø4” (10cm) double walled flex pipe 8 11⁄2” wood screws 2 24” (61cm) section of
Inhaltszusammenfassung zur Seite Nr. 17
Initial Installation QUALIFIED INSTALLERS ONLY 11. Stretch the liner out. Attach the flexible liner to the vent termination cap by placing a small bead of high temperature silicone on the vent termination and slide the flex liner onto the vent terminal and secure with three (3) sheet metal screws evenly spaced. 12. Dress the flex liner through the wall thimble and attach the vent terminal to the outside of the house using four (4) wood screws provided. The use of non-hardening mastic should
Inhaltszusammenfassung zur Seite Nr. 18
Initial Installation QUALIFIED INSTALLERS ONLY 16. Slide the 90° elbow over the flex pipe. Do not slip the outer sections of pipe together, you will require some movement in these pipe section in order to secure the flex pipe to the flue outlet on the appliance. 17. Stretch the flex liner to a length long enough to ensure the flex liner can be easily connected to the flue outlet of the appliance. 18. Install the remaining wire spacers over the flexible liner and install the vertical section
Inhaltszusammenfassung zur Seite Nr. 19
Initial Installation QUALIFIED INSTALLERS ONLY Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent GS Direct-Temp Secure Vent Ameri Vent Description Direct 908 4DT-6 SV4L6 6” pipe length 4D7 7” pipe length 907 4DT-9 9” pipe length 906 4DT-12 SV4L12 4D12 12” pipe length 904 4DT-24 SV4L24 4D2 24” pipe length 903 4DT-36 SV4L36 4D3 36” pipe length 902 4DT-48 SV4L48 4D4 48” pipe length 945 4DT-EL45 SV4EBR45 4D45B 45° elbow, black 990 4DT-EL90 SV4EBR90 4D90
Inhaltszusammenfassung zur Seite Nr. 20
Initial Installation QUALIFIED INSTALLERS ONLY VENT CONFIGURATIONS: Figures 22 shows the range of venting options, it shows possible vent configurations if the unit is top vented, for vertical and horizontal terminations, any layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement. Using 45˚ elbows is preferable to using 90˚ elbows. Also, a shorter vent system will perform better than a longer one. NOTE: T