Inhaltszusammenfassung zur Seite Nr. 1
®
COUNTRYSIDE
CORN/WOOD PELLET STOVE /FIREPLACE INSERT
Safety tested and EPA exemption tested by Warnock Hersey to UL 1482, CAN/ULC-S627, ULC-S628, APFI
requirements, Oregon administrative rules 814-23-900 to 814-23-909 and E.P.A. Method 28A.
OWNER’S MANUAL
Installation – Operation – Maintenance Instructions
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS CORN/PELLET
BURNING STOVE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY
Inhaltszusammenfassung zur Seite Nr. 2
TABLE OF CONTENTS PAGE CLEAN BURN (special additive) & ESTIMATED FUEL FEED RATE CHART………….. 3-4 INTRODUCTION & SPECIFICATIONS………….……………………………………….... 5 SAFETY STEPS ……………………………………………………………………………... 6 BURNING SOLID FUELS (SHELLED CORN/WOOD PELLETS)………………………... 7-8 UNPACKING YOUR COUNTRYSIDE STOVE……………………..……………………... 8 INSTALLATION REQUIREMENTS (FLOOR PROTECTION)………………..………... 9 CLEARANCES TO COMBUSTIBLES……………………………………………………… 10 GUILDELINES FOR EXHAUST SYSTEMS DESIGNS…………………………………… 11-
Inhaltszusammenfassung zur Seite Nr. 3
CLEAN BURN CORN ADDITIVE TM AMERICAN ENERGY SYSTEMS INC. HAS DEVELOPED AN ADDITIVE THAT WHEN MIXED WITH CORN VIRTUALLY ELIMINATES THE (CLINKERING) THAT IS CAUSED BY THE COMBUSTION PROCESS OF BURNING CORN. HOW DOES IT WORK AND WHY DO YOU NEED IT? The clean burn additive is a unique blend of the right ingredients that will oxygenate the combustion process producing a cleaner more productive fire. This will generate more BTU’S out of corn, clean up the combustion process and pr
Inhaltszusammenfassung zur Seite Nr. 4
Inhaltszusammenfassung zur Seite Nr. 5
DEAR VALUED COUNTRYSIDE OWNER, We appreciate your decision to help preserve our precious environment by purchasing the Countryside Corn/Wood Pellet Appliance. With everyone working together, we can have clean air and renewable heat for our homes. Please read this Owners Manual carefully before using this appliance and if you have any questions contact your local Countryside reseller. We appreciate your business and wish you many warm days and nights with your new Countryside Corn/Woo
Inhaltszusammenfassung zur Seite Nr. 6
SAFETY STEPS IMPORTANT: Proper installation of this stove is crucial for proper and safe operation. Installing this product improperly may result in a house fire and personal injury. All applicable building codes for your location must be followed. In areas where building codes require additional steps to the installation of this product not included in this manual, the building codes will take precedent and must be followed. Contact your local building inspector to obtain an
Inhaltszusammenfassung zur Seite Nr. 7
BURNING SOLID FUELS (shelled corn and wood pellets) Unlike petroleum and natural gas products, solid fuels such as corn and wood pellets create ash as the fuel is burned. Even with the highly efficient flame your Countryside stove will produce, the solid fuels used will produce ash. This ash will have to be cleaned out of the stove from time to time. The cleaning procedure will be discussed later in this manual. You can minimize the amount of cleaning required and maximize the ef
Inhaltszusammenfassung zur Seite Nr. 8
There are many varieties of corn grown around the world. Each variety has unique characteristics including the shape and size of the kernel. Your stove will burn more consistently with a small to mid-size kernel corn. If the kernel size of the corn varies greatly or if you switch sources frequently, you will get a less consistent burn, which will require more attention to the draft setting on your stove. Therefore, purchasing corn from the same source will help achieve a more consistent
Inhaltszusammenfassung zur Seite Nr. 9
The Pedestal Ash Pan unit comes completely assembled, the Insert comes with the shroud packaged separately and the Leg unit comes with the Legs packaged in the hopper. The installation of the Insert Shroud is shown later in the installation manual. Make sure that the shroud is with the unit when you get it. The following diagram will show how to install the legs on the Leg Unit. The legs are wrapped up and packaged in the hopper. Unpackage the legs and get the (4) nuts out of the hardw
Inhaltszusammenfassung zur Seite Nr. 10
Inhaltszusammenfassung zur Seite Nr. 11
GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN It is recommended that only an authorized Countryside installer install your pellet/corn stove. The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove and to local building codes. A listed 3” or 4” type “PL” pellet vent exhaust system must be used for FREESTANDING installation and attached to the pipe connector provided on the back of the stove. Use a 3” to 4” adapter for
Inhaltszusammenfassung zur Seite Nr. 12
GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN, CONT…… To determine whether a 3” or 4” exhaust system should be used, follow the guidelines below: 1) Determine the “equivalent pipe length” for each component used according to the comparison chart below. Add the “equivalent pipe length” of all components to get the “total equivalent pipe length”. 2) Determine the altitude at which you are installing the stove. 3) Cross-reference the “total equivalent pipe length” and the altitude usi
Inhaltszusammenfassung zur Seite Nr. 13
DESIGN GUIDELINES FOR OUTSIDE COMBUSTION AIR CONNECTION OUTSIDE MAKE-UP AIR FOR COMBUSTION IS REQUIRED ON ALL INSTALLATIONS 1) For FREESTANDING installations with horizontal through-the-wall exhaust, it is REQUIRED that the stove combustion air intake be connected to a fresh air intake outside. If the home is newer or has been tightly insulated it is imperative to the operation of the unit to install outside combustion air. If you do not, then an additional 6 inch intake into the f
Inhaltszusammenfassung zur Seite Nr. 14
INSTALLATION CONFIGURATIONS The Countryside Corn/Pellet Stove Model J3500/3500P may be installed as follows: 1) A freestanding unit (with a pedestal only) 2) A hearth mounted fireplace insert into a masonry or factory built fireplace (3502 only) 3) A built-in heater mounted in an alcove with a pedestal 4) A built-in heater mounted on a non-combustible floor without a pedestal MOBILE HOME INSTALLATION REQUIREMENTS IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTION, THE FOLLOW
Inhaltszusammenfassung zur Seite Nr. 15
ALCOVE INSTALLATION REQUIREMENTS The Countryside is approved for the standard alcove height of 72 inches, or for a reduced alcove height with a minimum of 14 inches from the top of the stove (clearance for opening top lids). The maximum alcove depth is 60 inches and the listed side clearances are a minimum of 1 inch. The 14” clearance is only needed for opening the back lid. If the front lid protrudes out of the opening a 1” clearance is all that is required. ALCOVE - THROUGH THE WALL
Inhaltszusammenfassung zur Seite Nr. 16
FREESTANDING STOVE INSTALLATION REQUIREMENTS Horizontal Exhaust Termination: 1) Locate proper position for the type “PL” wall thimble (F). Use a saber saw or key- hole saw to cut a 2) 7 1/4-inch diameter hole through the wall (G) for a 3-inch pipe. For a 4-inch pipe, cut an 8 1/4-inch hole. Install the wall thimble in the hole. The size of hole opening will vary with brand of wall thimble. 3) Position stove approximately 12” from the wall on the noncombustible floor pad. Push t
Inhaltszusammenfassung zur Seite Nr. 17
Storm Collar Required Locate so that exhaust does not interfere with fresh air Required 17
Inhaltszusammenfassung zur Seite Nr. 18
Storm Collar This type of installation is not recommended in cold climates unless closed in and insulated. Required Required WARNING: Unless the venting is enclosed and insulated this installation will cause poor venting and serious creosote buildup in cold climate areas. 18
Inhaltszusammenfassung zur Seite Nr. 19
FIREPLACE INSERT INSTALLATION REQUIREMENTS The Countryside Model 3502 Fireplace Insert may be installed in a masonry factory built fireplace or on a non-combustible floor as shown below. NOTE: When installing as a fireplace insert, the unit must extend out of the fireplace opening 12” to accommodate access to the circuit board panel, draft slide (located on the left side of the insert) and the top front hopper lid (to fill the hopper with fuel). CAUTION There are serious conseque
Inhaltszusammenfassung zur Seite Nr. 20
FIREPLACE INSERT INSTALLATION CONTINUED…… The Countryside Model 3502 Fireplace Insert requires a fireplace shroud for proper installation. The shroud is designed to slip over the stove-top between the front and back hopper lids. Shrouds can be customized for particular installations (custom order). 1) Position unit so that the shroud can be slid over the top lid behind the sliding draft control knob (located on the left side of the unit). Alternate Method: Open the back lid, slide shr