Inhaltszusammenfassung zur Seite Nr. 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Westport
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrical switch or
use any phone in your building.
• Immediately call your gas supplier from
a neighbour’s phone. Follow the gas
supplier’
Inhaltszusammenfassung zur Seite Nr. 2
Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, do not allow anyone who is in accordance with their instructions. Carefully read all unfamiliar with the stove to operate it. the instructions in this manual first. Consult the building • To prevent injury, if the pilot or pilot and authority having jurisdiction to determine the need for burn
Inhaltszusammenfassung zur Seite Nr. 3
Table of Contents Safety Precautions.....................................................................................................2 Table of Contents......................................................................................................3 Codes And Approvals.................................................................................................4 Specifications............................................................................................................
Inhaltszusammenfassung zur Seite Nr. 4
Codes And Approvals DIRECT VENT ONLY: This type is identified by the sufix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. TOP VENT DV Certified for installation from 0-4500 ft (0-1372 m) REAR VENT DV Certified for installation from 0-4500 ft (0-1372 m) with 36” (915 mm) snorkel (refer to ‘Converting Top Vented into Rear Vented’). In the USA: The appliance may be installed at higher altitudes. Please refer to y
Inhaltszusammenfassung zur Seite Nr. 5
Specifications WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. DIMENSIONS: 1 1 5 / 8 " 25 3⁄4 " ( 3 9 . 0 c m ) ( 65 . 3 c m ) 2 7 " 27" ( 6 8 .5 c m ) ( 68. 6 c m ) 1 5 3⁄4 " 25 3⁄4 " ( 4 0 . 0 c m ) ( 6 5. 4 c m) 1 1 7 / 8 " ( 4 3 .5 c m ) F l o o r t o c e n t e r o f f l u e 5 1 6 / 8 " R E A R V E N T ( 4 2 . 2 c m ) 2 3 1⁄2 ” ( 5 9 . 7 c m ) 25 3⁄4 " ( 6 5 . 3c m )
Inhaltszusammenfassung zur Seite Nr. 6
I P F F H OT W H I L E O P E R A T IN G. D O N OT T OU C H . K E E P C H I L D R E N , C L OT H I N G , F U R N I T U R E , C A U T I O N : G A S O L IN E , O R O T H E R F L A M M A B L E V A P O U R S A W A Y . F O R Y OU R S A F E T Y : D o not op e r a t e thi s f i r ep l a c e w i t h t he g l ass r e m o ved , c r acke d, o r b r oken . R epl a c em en t o f th i s g l as s s h o ul d b e i nstal l e d w i th p r o vi si ons for co m bus ti on a n d by a l i cen s e d o r q ual i fi ed pe
Inhaltszusammenfassung zur Seite Nr. 7
Operating Instructions PILOT LIGHT: 1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE OPEN FLAME FOR LEAK TESTING. 2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several times � � � � � � � � �� � � � � � � � � � � � � u
Inhaltszusammenfassung zur Seite Nr. 8
Maintenance And Service ROUTINE MAINTENANCE: At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips. Warning: Clearances must be sufficient to allow access for maintenance and service Warning: Failure to position the parts in accordance with this manua
Inhaltszusammenfassung zur Seite Nr. 9
Maintenance And Service REPLACING THE GLASS: The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see PARTS LIST - COMPONENTS). Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate with the glass front removed, cracked or broken. Removal and replacemen
Inhaltszusammenfassung zur Seite Nr. 10
Maintenance And Service TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY FUEL CONVERSION: Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qual
Inhaltszusammenfassung zur Seite Nr. 11
Maintenance And Service Step 8. Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood and reinstall the hood by placing the hood on the assembly, line up the key way, and snap into place. Step 9. Remove the main burner orifice with a 1⁄2 inch deep socket. Step 10. Install the new orifice supplied. Be sure to put a bead of pipe-thread sealant or approved Teflon tape on the orifice before installing into the burner assembly. Step
Inhaltszusammenfassung zur Seite Nr. 12
Initial Installation QUALIFIED INSTALLERS ONLY VENT TERMINATION RESTRICTIONS: N O H D E B C B F i x e d B G C l o s e d L F i x e d O p e na b l e F C l o se d G O p e na b l e M J K B A I A T e r m i na ti o n C a p A i r S u p p l y I nl e t R e st r i cti o n Z one G G a s M e te r ( Te r m i na t i on n o t a l l o w e d) Figure 10. Vent Termination Restrictions, refer to Table 2. Table 2: Vent termination clearances, refer to Figure 10. 1 2 Letter Canadian Installation US Installation Desc
Inhaltszusammenfassung zur Seite Nr. 13
Initial Installation QUALIFIED INSTALLERS ONLY APPROVED VENT PARTS: Table 3: Approved Vent Manufacturers Manufacturer Trade Name Nominal Sizes American Metal Products Ameri Vent Direct 4/6 and 5/8 Security Chimneys International LTD Secure Vent 4/6 and 5/8 Selkirk Metalbestos Direct-Temp 4/6 Simpson Dura Vent Direct Vent GS 4/6 and 5/8 Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent Direct- Secure Vent Ameri Vent Description GS Temp Direct 908 4DT
Inhaltszusammenfassung zur Seite Nr. 14
Initial Installation QUALIFIED INSTALLERS ONLY This fireplace have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SELKIRK DIRECT-TEMP SYSTEM SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS MDV VENT SYSTEM” kits are available for horizontal venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each
Inhaltszusammenfassung zur Seite Nr. 15
Initial Installation QUALIFIED INSTALLERS ONLY NOTE: The total length of the vent pipes can not exceed 30 Slide the hex head bolt to the next feet (9.14 m). Any combination of rise and run can be 3 0 ’ setting and re-tighten the bolt to ( 9 . 1 4 m ) used as long as it lays within the shaded area (a total secure in place. of three (3) 90° elbows or six (6) 45° elbows can be used). In addition to what is shown, if a 90° The numbers in this chart represent elbow is used in the horizontal p
Inhaltszusammenfassung zur Seite Nr. 16
Initial Installation QUALIFIED INSTALLERS ONLY R o u n d S u ppor t B o x / W al l T h i m b l e Your total vent pipe length must be within the shaded area of Figure 12. If a 90° elbow is used in the horizontal plane, 36” (91.4 cm) must be subtracted from the allowable horizontal run. H or i zont a l There are three (3) basic types of Direct Vent T e r m i nati on System installations. The three (3) types of installations are shown in Figures 13 through P i pel eng th 15. 9 0 ° E l b o w
Inhaltszusammenfassung zur Seite Nr. 17
Initial Installation QUALIFIED INSTALLERS ONLY HORIZONTAL INSTALLATION: STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance. STEP 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented t
Inhaltszusammenfassung zur Seite Nr. 18
Initial Installation QUALIFIED INSTALLERS ONLY every 36 inches (915 mm). Wall straps are available for this purpose, also when running horizontal pipe minimum clearances to combustibles must be maintained; 2 inches (51 mm) at top, 11⁄2 inches (38 mm) at sides, 11⁄2 inches (38 mm) at bottom. STEP 3. With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4 cm) x 10” (25.4 cm) square hole (refer to Figure 17). The center of the square hole should match the cent
Inhaltszusammenfassung zur Seite Nr. 19
Initial Installation QUALIFIED INSTALLERS ONLY NOTES: (1) The four (4) wood screws provided should be replaced with the appropriate fasteners for stucco, brick, concrete, or other types of siding. (2) For buildings with vinyl siding, a vinyl siding standoff, should be installed between the vent cap and the exterior wall (see Figure 19). Attach the vinyl siding standoff to the horizontal termination. The vinyl siding standoff prevents excessive heat from possibly melting the vinyl siding mat
Inhaltszusammenfassung zur Seite Nr. 20
Initial Installation QUALIFIED INSTALLERS ONLY VERTICAL INSTALLATION: STEP 1. Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. Do not pack air spaces with insulation. STEP 2. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate th