Inhaltszusammenfassung zur Seite Nr. 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
PELLET STOVE
Ev olution
TECHNICAL MANUAL
� � � �
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE
OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY
OR EVEN DEATH
Contact your building or fire officials about restrictions and installation
inspection requiremen
Inhaltszusammenfassung zur Seite Nr. 2
Table of Contents Safety Warnings & Recommendations...............................................................................................3 Installation.....................................................................................................................................6 Rating Label Location................................................................................................................6 Deciding Where to Locate your Pellet Appliance........................
Inhaltszusammenfassung zur Seite Nr. 3
Safety Warnings & Recommendations * This manual is designed for the technician in conjunction with the owner’s manual. * Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Any unauthorized modification of the appliance or use of replacement parts not recommended by the manufacturer is prohibited. All national and local regulations and European Standard
Inhaltszusammenfassung zur Seite Nr. 4
Safety Warnings & Recommendations CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. This will vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect and clean the exhaust vent semi-annually or every two tons of pellets. The appliance, flue gas connector and the chimney flue require regular cleaning. Check them for blockage prior to re-lighting after a prolonged shut down period. ASHES: Disposed ashe
Inhaltszusammenfassung zur Seite Nr. 5
Safety Warnings & Recommendations FRESH AIR: Outside Fresh Air connection is optional. Fresh Air must be connected to all units installed in “Air Tight Homes” or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly. NOTE: Extractor fans when operating in the same room or space as the appliance, may cause problems. Limited air for combustion may result in poor performance, smoking and other side effects of poor combus
Inhaltszusammenfassung zur Seite Nr. 6
Installation RATING LABEL LOCATION: The rating label is located on the inside of the ash pan cover. DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE: 1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install the stove in a bedroom. 4. You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry or metal chimney (mu
Inhaltszusammenfassung zur Seite Nr. 7
Installation DIMENSIONS: Unit Dimensions 1 Height: 840 mm (33 /16”) Width: 565 mm (22 1⁄4”) 7 Depth: 539 mm (21 1⁄4”) 2 7 / 8 " ( 7 0 8 m m ) Hearth Pad: Width: 619 mm (24 3⁄8”) IMPORTANT: When not installing Depth: 708 mm (27 7⁄8”) the optional Hearth Pad on the unit, the minimum requirements 3 2 4 / 8 " ( 6 1 9 m m ) 1 21 / 4 " for protection on combustibles 1 2 2 / 4 " ( 5 6 5 m m ) ( 5 39 m m ) floors are a width of 620mm (243⁄8”) & depth of 670mm (263⁄8”) under the
Inhaltszusammenfassung zur Seite Nr. 8
A d j a c e n t W a l l Installation CLEARANCES TO COMBUSTIBLES: This unit can be installed on a combustible floor when installed with the optional hearth pad part 50-1568 (for example linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth pad must be used for stability. B a ck W a l l 4 " 4 " ( 1 0 cm ) ( 1 0 cm ) These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing, routine cleaning and mainten
Inhaltszusammenfassung zur Seite Nr. 9
Installation HEARTH PAD PEDESTAL INSTALLATION: This unit can be installed on a combustible floor (e.g. linoleum, hardwood flooring) when the Optional Hearth Pad is installed. If this unit is to be installed onto a carpeted surface, a solid pad must be used underneath the Optional Hearth Pad for stability. Carefully place the the pellet appliance on its back, on the pallet (allow the exhaust tube to fit thru an opening in the pallet). Align the holes in the hearth pad and the unit and install
Inhaltszusammenfassung zur Seite Nr. 10
Installation VENT TERMINATION REQUIREMENTS: IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER. Table 2: Use in conjunction with Figure 6 for allowable exterior vent termination locations. Letter Minimum Clearance Description A 61cm (24 in) Above grass, top of plants, wood, or any other combustible materials. B Beside/below any door or window that may be opened. (46 cm (18”) if outside 122 cm (48 in) fresh air install.) C Above any door or window that ma
Inhaltszusammenfassung zur Seite Nr. 11
Installation OUTSIDE FRESH-AIR CONNECTION: This Heater must have adequate air for proper combustion in the room that it is installed. A Fresh-air intake is strongly recommended for all installations. Failure to install intake air may result in improper combustion as well as the unit smoking during power failures. � � � � � � � � � � � The inlet to the intake must be below and a minimum of 305mm (12”) away from the unit exhaust outlet. Outside fresh air is mandatory when installing this uni
Inhaltszusammenfassung zur Seite Nr. 12
Installation MOBILE HOME INSTALLATION: ● Secure the heater to the floor using the two holes in the pedestal. ● Ensure the unit is electrically grounded to the chassis of your home (permanently). ● Do not install in a room people sleep in. ● Outside fresh air is mandatory. Secure outside air connections directly to fresh air intake pipe and secure with three (3) screws evenly spaced. CAUTION: THE STRUCTURAL E N V I R O E F 5 INTEGRITY OF THE O p t i o na l MANUFACTURED HOME FLOOR, H ea
Inhaltszusammenfassung zur Seite Nr. 13
Installation HORIZONTAL EXHAUST THROUGH WALL INSTALLATION: Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired, the installation must conform with all local regulations, including those referring to regional, national or European Standards. Use 80mm stainless
Inhaltszusammenfassung zur Seite Nr. 14
Installation • Follow vent manufacturer’s guidelines for installation of venting. High temperature sealant must be used when connecting the vent pipe to the unit’s starter pipe. Improper seals at the vent joints may cause combustion byproducts to leak into the room where installed - seal as required.. THROUGH WALL WITH VERTICAL RISE AND HORIZONTAL TERMINATION INSTALLATION- RECOMMENDED: � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �
Inhaltszusammenfassung zur Seite Nr. 15
Installation INSIDE VERTICAL INSTALLATIONS: 1. Choose a stove location that is ideal. See the section “DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE.” 2. Place a non-combustible hearth pad where necessary. 3. Place the unit on the hearth pad (if R ai n C ap ( ensur e cap installed on a carpeted surface) and i s at l east 3 f t ( 91cm ) space the unit in a manner so when above t he r oof at t he 2 f t l ow est poi n t ) ( 61 cm) the pellet vent is installed vertically, it will be 100mm (4”)
Inhaltszusammenfassung zur Seite Nr. 16
Installation R ai n c a p F l a sh i ng 2 4 " ( 6 1 c m ) 3" ( 7 . 5 cm ) C l e ar an c e 4 " ( 1 0 c m ) S uppor t br ac k et T ee w i th c l e a no ut T y pe " L " v e n t F r e s h ai r i n ta k e Figure 15: Outside Vertical Installation. HEARTH MOUNT INSTALLATION: R ai n C a p S e a l P l at e Refer to Figures 16. 1. Lock fireplace damper in the open position. 2. Install a positive flue connector at the E x i s ti n g M as onar y fireplace dampers. F l ue 3. Connect a tee or a 90° elbow to
Inhaltszusammenfassung zur Seite Nr. 17
Installation EXTERIOR MOUNTED EXHAUST BLOWER: The Evolution can be equipped with an externally mounted exhaust blower. This optional kit includes all components necessary to install the exhaust blower on any vertical wall surface. Choose a location for your stove that meets the requirements stated in your manual and allows installation with the least amount of interference with house framing, plumbing, wiring, etc. Included in the Exterior Mounted Exhaust Blower Kit are: 1 - Exhaust blower
Inhaltszusammenfassung zur Seite Nr. 18
Installation TYPICAL THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - HORIZONTAL TERMINATION: E F 5 9 0° E l bo w 4 5° E l b o w w i t h R o d e nt s cr e en or s tai n l e ss s teel t er m i n a ti o n ho od 2 f t R i s er P i p e A da p t or E x t e r i or B l o w e r E l e ct r i c al C a b l e and H o u si ng Figure 20: Through Wall Installation with Exterior Blower Kit. NOTE: Ensure that all interior vent connections are sealed by placing a small bead of high temperature silicone arou
Inhaltszusammenfassung zur Seite Nr. 19
Installation TYPICAL THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - VERTICAL TERMINATION: Follow the previous pages for through wall installations. Ensure that vent pipe is properly secured to wall using wall straps. Maintain clearances to combustibles on vent pipe as well as unit. R oo f S he a t h i ng R ai n C ap R oof F l as hi ng R o o f R af te r s C e i l i n g Joi s ts V e nt P i pe E xt e r i or W a l l S h eathi ng O u tsi de V e n t T e r m i n at i o n E F 5 Figure 22: Through
Inhaltszusammenfassung zur Seite Nr. 20
Installation THERMOSTAT INSTALLATION: 1. Install the wall thermostat (12 or 24 Volt rated) in a location that is not to close too the unit but will effectively heat the desired area. 2. Connect the Thermostat or Timer using an 2 x 18 gauge wire from the unit to the thermostat. If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to the setting that is