Inhaltszusammenfassung zur Seite Nr. 1
www.regency-fi re.com
Owners &
G36D Zero Clearance Direct Vent Gas Fireplace
Installation Manual
MODELS: G36D-NG Natural Gas G36D-LP Propane
WARNING: If the information in these instructions are not followed exactly,
FOR YOUR SAFETY
a fi re or explosion may result causing property damage, personal injury
What to do if you smell gas:
or loss of life.
FOR YOUR SAFETY: Do not store or use gasoline or other fl ammable
Do not try to light any appliance.
vapors and liquids in the vicini
Inhaltszusammenfassung zur Seite Nr. 2
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by FIREPLACE PRODUCTS INTERNATIONAL. The G36D is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model G36D has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. P
Inhaltszusammenfassung zur Seite Nr. 3
TABLE OF CONTENTS Page Page Safety Label Operating Instructions Safety Label ............................................................... 4 Operating Instructions .............................................. 32 Lighting Procedure ................................................... 32 Installation Shutdown Procedure ................................................ 32 First Fire ................................................................... 32 Important Message .......
Inhaltszusammenfassung zur Seite Nr. 4
SAFETY LABEL This is a copy of the label that accompanies each G36D Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open. NOTE: UltraGlow units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. For the State of Massachusetts, installation and repair must
Inhaltszusammenfassung zur Seite Nr. 5
INSTALLATION 14) Under no circumstances should any solid IMPORTANT: CLOTHING OR OTHER FLAMMABLE fuels (wood, paper, cardboard, coal, etc.) MATERIAL SHOULD NOT BE PLACED be used in this appliance. SAVE THESE ON OR NEAR THE APPLIANCE. INSTRUCTIONS 15) The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids). The G36D-NG or G36D-LP Direct Vent Fireplace must be installed in accordance with these in- GENERAL SAFETY Emissio
Inhaltszusammenfassung zur Seite Nr. 6
INSTALLATION This includes: MANUFACTURED 5) This appliance is Listed for bedroom instal- 1) Clocking the appliance to ensure the correct lations when used with a Listed Millivolt MOBILE HOME fi ring rate (rate noted on label 26,000 Btu/h) Thermostat. Some areas may have further after burning appliance for 15 minutes. ADDITIONAL requirements, check local codes before installation. REQUIREMENTS 2) If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow 6)
Inhaltszusammenfassung zur Seite Nr. 7
INSTALLATION 2) Frame in the enclosure for the unit with CLEARANCES MANTEL LEG framing material. The framed opening is 37-1/4" high x 36-1/4" wide x 17-3/8" deep CLEARANCES The clearances listed below are Minimum (946mm high x 921mm wide x 441mm distances unless otherwise stated: deep). Combustible mantel leg clearances as per diagram below: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest imp
Inhaltszusammenfassung zur Seite Nr. 8
INSTALLATION COMBUSTIBLE MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board. These drawings are to scale at 1:6 (one inch = 6 inches) Mantel can be installed anywhere in shaded area or higher using the above scale. Note: Ensure the pain
Inhaltszusammenfassung zur Seite Nr. 9
INSTALLATION 3) Attach the standoff securely to the top TopHeader with 2 screws per standoff (on opposite 10"dia.hole corners). throughwall 1/2" forFlex Drywall orforDuraVent "C" Screw Position: For a facing material depth of 1-1/4" 2" (32mm), the top facing support must be reversed. 3-1/2" 4" 17-1/8" Openingforgas connectio n Note: 40-1/2" (1029mm) is the minimum height for both fl ex termination or Simpson Dura-Vent venting. Top Facing Support and Side Nailing Strips 5) The unit does not
Inhaltszusammenfassung zur Seite Nr. 10
INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS 10 UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace V V . Vertical Inside corner detail Termination Vertical Termination G V A 24" 24" 18" D V E H B B C M Fixed B V V Closed Openable Fixed Closed V Openable V F N B L V A B K V A B j A Air supply outlet Area where terminal is not permited Vent terminal A V A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) H= Not to be installed above a meter/regulator assembly withi
Inhaltszusammenfassung zur Seite Nr. 11
INSTALLATION VENTING UltraGlow Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the G36D Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 10. UltraGlow Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the G36D with a maximum
Inhaltszusammenfassung zur Seite Nr. 12
INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. R Description Simpson Dura-Vent Selkirk Amerivent R TM Direct VentGS Direct-Temp Direct Vent 6" Pipe Length, Galvanized 908 4DT-6 N/A 6" Pipe Length, Black 908B 4DT-6B N/A 7" Pipe Length, Galvanized N/A N/A 4D7 7" Pipe Length, Black N/A N/A 4D7B 9" Pipe Length, Galvanized 907 4DT-9 N/A 9" Pipe Length, Blac
Inhaltszusammenfassung zur Seite Nr. 13
INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations The minimum components required for a basic horizontal termination are: Flat Wall Installation Wall Thickness Vent Length 1 Horizontal Termination Cap (inches) Required (inches) o 1 90 Elbow 4" - 5-1/2" 6" 1 Rigid Pipe Adaptor 7" - 8-1/2" 9" 1 Wall Thimble 10" - 11-1/2" 12" 1 Length of pipe to suit wall thi
Inhaltszusammenfassung zur Seite Nr. 14
INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS ULTRAGLOW DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) o o o The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 elbow (two 45 elbows equal one 90 elbow). Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems. All Rigid Pipe Systems 4" inner diameter 6-5/8" outer diameter UltraGlow Flex Vent 4" inner diameter 6-7/8" inner di
Inhaltszusammenfassung zur Seite Nr. 15
INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS ULTRAGLOW DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) o o o The diagram below shows examples of horizontal termination arrangements using two 90 elbows (two 45 elbows equal one 90 elbow). o Note: 1) A maximum of two 90 elbows are permitted. o 2) A minimum of 6 ft. (1.8m) vertical from base of unit is required if two 90 elbows are used. 3) Minimum distance between elbows is 2 ft. (0.6m). 4) Determine the permitted r
Inhaltszusammenfassung zur Seite Nr. 16
INSTALLATION RIDID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS (Propane & Natural Gas) The G36D is approved for a maximum 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset o o o using two 90 elbows (two 45 elbows equal one 90 elbow) with Rigid Pipe vent systems for Propane and Natural Gas, as per diagram 1. The G36D is approved for a maximum 37 ft. (11.3m) straight vertical, including a maximum 20" (0.5m) horizontal o o o offset using two 90 elbow (two 45 elbow
Inhaltszusammenfassung zur Seite Nr. 17
INSTALLATION The G36D is approved for a maximum 37 ft. (11.3m) straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas, as per the diagram 3. The shaded area in the diagram 3 shows all allowable combinations of straight vertical and offset to vertical terminations with Rigid Pipe vent systems for o Propane and Natural Gas. Maximum two 45 elbows allowed. • Vent must be supported at offsets • Firestops are required at each fl oor level and whenever passing through a wall.
Inhaltszusammenfassung zur Seite Nr. 18
INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE Masonry chimneys may take various contours which the fl exible liner will accommodate. However, CONNECTED TO A CHIMNEY FLUE keep the fl exible liner as straight as possible, avoid unnecessary bending. SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. The Air Intake pipe must be attached to the inlet air collar of the termination cap. This appliance is designed to be attached to two 3" (76mm) co-linear alumin
Inhaltszusammenfassung zur Seite Nr. 19
INSTALLATION Venting Arrangements - Vertical Terminations with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations. UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 19
Inhaltszusammenfassung zur Seite Nr. 20
INSTALLATION b) Horizontal runs of vent must be HORIZONTAL supported every three feet. Wall straps are available for this purpose. INSTALLATIONS 5) Mark the wall for a 10" x 10" square hole. Install the vent system according to the The center of the square hole should line manufacturer's instructions included with up with the centerline of the horizontal pipe. the components. Cut and frame the 10 inch square hole in the exterior wall where the vent will be 1) Set the unit in its des