OPERATIONS MANUAL FOR THE MODEL DV23ZC
DIRECT VENT ZERO CLEARANCE GAS FIREPLACE
APPROVED FOR MOBILE HOME INSTALLATION
WARNING: If the following information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.
-DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
-WHAT TO DO IF YOU SMELL GAS
* D
Inhaltszusammenfassung zur Seite Nr. 2
Inhaltszusammenfassung zur Seite Nr. 3
TABLE OF CONTENTS Introduction .......................................................................................................................... 3 Specifications ....................................................................................................................... 3 Installation ........................................................................................................................... 5 Location and Clearance .......................................
Inhaltszusammenfassung zur Seite Nr. 4
2
Inhaltszusammenfassung zur Seite Nr. 5
INTRODUCTION This instruction manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system. Please read and understand these instructions before beginning your installation. The model DV23ZC is a sealed combustion, air circulating gas appliance designed for residential and mobile home applications. The appliance must be installed with Dura-Vent GS vent system that is routed to outside atmosphere. It is also listed for bedroom installations
Inhaltszusammenfassung zur Seite Nr. 6
NOTE: Installation and repair should be performed by a qualified service person. The appliance should be inspected annually by a qualified professional service person. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, pet hair, etc. It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean. Provide adequate clearances around air openings and adequate accessibi
Inhaltszusammenfassung zur Seite Nr. 7
GENERAL INFORMATION LOCATION AND CLEARANCE Make sure your installation location provides adequate combustion and ventilation air. In selecting the location, the aesthetic and functional uses of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important. Consideration should be given to traffic ways, furniture, draperies, etc., due to elevated surface temperatures. The location should also be free of electrical,
Inhaltszusammenfassung zur Seite Nr. 8
INSTALLATION Figure 1 6
Inhaltszusammenfassung zur Seite Nr. 9
NOTE: * SUPPLIED BY MANUFACTURER INTERIOR HORIZONTAL MINIMUM INSTALLATION NOTE: * NOTE: You may replace or cover this piece of material with a * more decorative non-combustible SUPPLIED BY MANUFACTURER material when the unit is installed. INTERIOR VERTICAL INSTALLATION WITH A MAXIMUM 42' RISE. Figure 2 7
Inhaltszusammenfassung zur Seite Nr. 10
INSTALLATION GENERAL INFORMATION Remove the shipping carton. Make sure the unit is not damaged. Lift the top louver and remove three (3) nuts at the upper left, right, and center of the glass frame. Also, open louver at bottom and remove the three (3) nuts. Set the door aside and protect from inadvertent damage. Retain nuts for reassembly. Next, carefully remove the box of logs inside the appliance and set these aside. 1. Framing - Maintain dimensions for the appliance enc
Inhaltszusammenfassung zur Seite Nr. 11
V V INSTALLATION EXTERIOR VENT LOCATIONS and RESTRICTIONS INSIDE CORNER DETAIL TERMINATION BOX, LOCATION CHART G V A H D E B C B L V FIXED FIXED CLOSED V CLOSED V F B M I B V J A B V A OPENABLE K A V A = VENT TERMINAL = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED A. Clearance above grade, veranda, porch, deck, or H. *Not to be installed above a meter regulator balcony (*12 inches (30cm) minimum) assembly within 3 feet (90 cm) horizontally from the centerline of the regula
Inhaltszusammenfassung zur Seite Nr. 12
INSTALLATION NOTE: Direct-Vent (Balanced Flue) appliances are sensitive to vent configurations. Although this appliance may operate in some installations that fall outside this vent requirement chart, we cannot ensure its performance. MINIMUM - MAXIMUM VENT REQUIREMENTS 42' 42' 18' 18' VENTING MUST BE TERMINATED WITHIN SHADED AREA 12' 12' 6' 6' 0' 0' * MINIMUM DISTANCE FROM BEND OF 45° ELBOW TO FACE OF VENT CAP.
Inhaltszusammenfassung zur Seite Nr. 13
INSTALLATION VENT ASSEMBLY There are two basic types of installations approved with your model DV23ZC appliance. These are: Horizontal termination (See Figure 5) Vertical termination (See Figure 10) When planning your installation, refer to Figure 3 to ensure the length of your vent falls into the limits specified in Figure 3. Also consult page 9, “Exterior Vent Locations and Restrictions” regarding the placement of the vent terminal. HORIZONTAL TERMINATION 1. Set the gas appl
Inhaltszusammenfassung zur Seite Nr. 14
INSTALLATION HORIZONTAL TERMINATION (continued) NOTE: The horizontal run of vent must be level, or have a 1/4-inch rise for every 1 foot of run toward the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire. A 2" clearance (airspace) MUST be maintained on all vent pipe. 4. With the pipe attached to the appliance adapter, slide the appliance into its correct location, and mark the wall for a 10" x 10" sq
Inhaltszusammenfassung zur Seite Nr. 15
INSTALLATION HORIZONTAL TERMINATION (continued) Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of siding. Venting termination shall not be recessed into a wall or siding. For structures with vinyl siding, a Vinyl Siding Standoff (Part 950) should be installed between the vent cap and the exterior wall. (See Figure 7.) Attach the Vinyl Siding Standoff to the Horizontal Vent Termination. The Vinyl
Inhaltszusammenfassung zur Seite Nr. 16
INSTALLATION VERTICAL TERMINATION 1. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof. Determine if the ceiling joists, roof rafters or other framing will obstruct the v
Inhaltszusammenfassung zur Seite Nr. 17
INSTALLATION VERTICAL TERMINATION (continued) 5. Slip the flashing over the Pipe Section(s) protruding through the roof. Secure the base of the Flashing to the roof with roofing nails. Ensure the roofing materials overlap the top edge of the Flashing as shown in Figure 12. Verify that you have at least the minimum clearance to combustibles at the roof line. Figure 12 6. Continue to add Pipe Sections until the height of the Vent Cap meets the minimum bu
Inhaltszusammenfassung zur Seite Nr. 18
INSTALLATION VERTICAL TERMINATION (continued) NOTES: Use only 45 degree elbows. Use of 90 degree elbows is not allowed in vertical terminations. The 45 degree elbows offer less restriction to the flow of flue gases and intake air. For multi-story vertical installations, a Ceiling Firestop, (Simpson-Dura-Vent, Part 963) is required at the second floor, and any subsequent floors (Figure 14). The opening should be framed to 10" x 10" inside dimensions, in the same manner as sho
Inhaltszusammenfassung zur Seite Nr. 19
INSTALLATION HIGH ALTITUDE This unit is approved in Canada for altitude from 0 to 2,000 ft. (0 to 600m) (Can 2.17-M90) with the main burner orifice supplied. For installations above 2,000 feet, follow current CAN/CGA-B149.1 and B149.2. In the USA refer to ANSI Z223.1 — latest edition, Appendix F, for resizing the orifice. At altitudes greater than 2,000 feet it is necessary to match the air and fuel requirements by installing a main burner orifice sized for the elevation that the a
Inhaltszusammenfassung zur Seite Nr. 20
L L I I P P INSTALLATION GAS VALVE CONNECTION The gas control valve is located behind the lower grill. The control valve has a 3/8" NPT threaded inlet port. Secure all joints tightly using appropriate tools and sealing compound. Leak-check the installation with a soapy water solution or electronic leak detector. DO NOT USE OPEN FLAME FOR LEAK TEST. SIT VALVE SUPPLY LINE 1/2" SHUT-OFF VALVE Figure 15 GAS PRESSURE CHECKS The gas valve is equ