Inhaltszusammenfassung zur Seite Nr. 8
SR/SC Series "A" Woodburning Fireplace Chimney Supports Installation The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9m) with SK8 chimneys or 20' (6m) with 3-wall chimneys. Locate chimney supports Insulating Fireplace Enclosure for at ceiling holes or other structural framing at 30' (9m) Cold Climates (SK8) or 20' (6m) (3-wall) heights. Spacing between If you live
Inhaltszusammenfassung zur Seite Nr. 9
SR/SC Series "A" Woodburning Fireplace Framing Option For Circulating Models Only — Framing can be constructed before or after the fire- EB1 (Receptacle) Hook-Up place is set in place, however, most installers build the frame before setting the fireplace. • Wiring should be installed by a certified electrician. Frame fireplace with 2 x 4 lumber or heavier materials. • Turn off circuit breaker before wiring models. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifi
Inhaltszusammenfassung zur Seite Nr. 10
SR/SC Series "A" Woodburning Fireplace Each offset requires two (2) elbows. The second elbow Straight-Up Chimney Installation is equipped with support straps. It is very important to To mark the centerline of the flue, put the fireplace in install the second elbow in each offset as close to the final position and measure out from the wall: 9¹⁄₄" ceiling or support as possible so that the elbow straps (235mm). Mark a spot on the ceiling directly above the can be secured to framing members to help
Inhaltszusammenfassung zur Seite Nr. 11
SR/SC Series "A" Woodburning Fireplace The following table gives firestop spacer model NOTE: Safety strips are not required over noncom- numbers: bustible floors where all supports at the base of the fireplace are noncombustible. Angle of Chimney at Ceiling Four (4) nailing flanges are incorporated on each Size of Chimney Vertical 30° corner of the surround. Bend the nailing flanges out, 8" Flue SKFS2A SKFS6A "SK" Series 14¹⁄₂" x 14¹⁄₂"14¹⁄₂" x 25¹⁄₂" level the box, then secure it firmly in pl
Inhaltszusammenfassung zur Seite Nr. 12
SR/SC Series "A" Woodburning Fireplace Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must Pipe Section install a firestop spacer. Pipe Rim Installing the Firestop Spacer Hem in the Ceiling Hole Lance Pipe A firestop spacer is used to keep pipe spaced properly Rim and required for safety. Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof. Hole si
Inhaltszusammenfassung zur Seite Nr. 13
SR/SC Series "A" Woodburning Fireplace Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails. Attic shields are not Attic required at the roof. Insulation Shield Nails Continue Installing Pipe to Complete Run (4 required) Continue attaching pipe sections to complete system to next level always being careful that the pipe is firmly snapped locked
Inhaltszusammenfassung zur Seite Nr. 14
SR/SC Series "A" Woodburning Fireplace Installing Top Housing Air Space Clearances or Termination Combustible framing material MUST NOT Follow the installation instructions provided with the penetrate AIR SPACE (shaded areas). chimney termination you have selected. Installing Chimney In a Chase Refer to Page 5, Figure 5 for an illustration of a typical 1¹⁄₂" chase installation. Standoff CAUTION: Treatment of firestop spacers and con- struction of chase may vary with type of building. ¹⁄₂" air
Inhaltszusammenfassung zur Seite Nr. 15
SR/SC Series "A" Woodburning Fireplace Mantel Clearance - Radiant Mantel Clearance - Radiant Model Mantel Clearance - Model - No Noncombustible - with Noncombustible Facing Circulating Model Facing Material Material Combustible Combustible Combustible 12" 12" Mantel and Trim 12" Mantel and Trim Mantel and (305mm) (305mm) (305mm) Trim Finished Wall Finished Wall Finished Wall Max. Max. Max. 1¹⁄₂" 1¹⁄₂" 1¹⁄₂" Header Header Header (38mm) (38mm) (38mm) 12" 12" 12" Standoff Standoff Standoff (
Inhaltszusammenfassung zur Seite Nr. 16
SR/SC Series "A" Woodburning Fireplace Hearth Installation Side Wall Protection Adjacent combustible side walls that are within the A hearth extension is required to protect a combustible minimum dimensions shown in Figure 23 of fireplace floor in front of the fireplace. Refer to Figure 23 for opening must be protected with CFM Corporation Wall minimum dimensions and mounting detail. Shield Model SP40 or a specifically built wall shield NOTE: Hearth Extension must not cover the air described be
Inhaltszusammenfassung zur Seite Nr. 17
SR/SC Series "A" Woodburning Fireplace Side View COMMON MATERIALS AND FACTORS Wall Covering MINIMUM MATERIAL K* R THICKNESS Noncombustible 2 x 4 Header EH2416 Decorative (Do not notch (CFM Corporation) 1.09 0.50 in.** 0.458 Facing at standoffs) Seal all cracks Common Brick 5.0 0.10 5.46 in.** between fireplace surround and wall materials with noncombustible R Value is for ¹⁄₂ inch. material * Units of K = BTU/SQ FT/HR/ßF/IN ** Thickness of Listed Material Noncombustible
Inhaltszusammenfassung zur Seite Nr. 18
SR/SC Series "A" Woodburning Fireplace Installing Line for Gas Logs Fireplace Top View Hole in Outer Casing CFM Specialty Home Products fireplaces are designed to accept a 1/2" (13mm) gas line for installation of an approved gas appliance. (CFM Specialty Home 1" Products manufactures a wide variety of gas logs for Min. Supply Gas Line Line use in CFM Specialty Home Products fireplaces.) Tube Be sure to have the appliance installed in accordance Ceramic Repack with building codes. Knockout Insul
Inhaltszusammenfassung zur Seite Nr. 19
SR/SC Series "A" Woodburning Fireplace 1 9 2 11 b 4 6 c d 3 a e 5 8 12 14 13 7 10 948 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. SR36A/42A, SC36A/42A SERIES For units FB40RO, GB40RO, FB40CO, GB40CO Item/Model Number SR/SC36A SR/SC42A 1. Damper Weld Assembly RP199 RP199 2. Damper Bracket 3030176 3030176 3. Screen Rod Assembly 3030126 3032112 4. Screen Assembly (two per
Inhaltszusammenfassung zur Seite Nr. 20
SR/SC Series "A" Woodburning Fireplace Accessories The following accessories for this appliance are available from your local Majestic Fireplaces distributor. Should you need additional information beyond what your distributor can furnish, contact: CFM Specialty Home Products, 410 Admiral Blvd., Mississauga, Ontario, Canada L5T 2N6, Attn: Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be operated only with CFM Specialty Home Pr
Inhaltszusammenfassung zur Seite Nr. 1
™
12345678901234567890123456789012123456
1 234567890123456789012345678901212345 6
1 234567890123456789012345678901212345 6
1 234567890123456789012345678901212345 6
1 234567890123456789012345678901212345 6
1 234567890123456789012345678901212345 6
1 234567890123456789012345678901212345 6
1 234567890123456789012345678901212345 6
1 234567890123456789012345678901212345 6
1 234567890123456789012345678901212345 6
1 234567890123456789012345678901212345 6
1 234567890123456789012345678901212345 6
1 234567
Inhaltszusammenfassung zur Seite Nr. 2
SR/SC Series "A" Woodburning Fireplace Safety Information PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Do not install combustible materials on any of the Description black fireplace surround. The SR/SC Series "A" fireplaces are solid fuel, wood- Burn only solid wood fuel or gas logs. burning
Inhaltszusammenfassung zur Seite Nr. 3
SR/SC Series "A" Woodburning Fireplace SR36A Series Woodburning Fireplace 22" (559mm) Rough Opening Depth 11" Dia. 48¹⁄₂" (1232mm) 8¹⁄₄" (279mm) ¹⁄₂" (13mm) (210mm) 22¹⁄₂" 8" Dia. (572mm) (203mm) 22" ⁵⁄₈" Recessed (559mm) (16mm) Nailing Flange Rough Opening Width 41" (1041mm) Rough Opening Height ¹⁄₂" 7¹⁄₂" (191mm) 39⁵⁄₈" 43³⁄₄" (1006mm) (1111mm) Outside 24" Gas Line Air (610mm) 7¹⁄₂" 36" Access 22³⁄₄" (191mm) (914mm) Gas Line (578mm) Access 14⁵⁄₈" (372mm) 11" 7³⁄₄" (279mm) (197mm) 8" 3" 40"
Inhaltszusammenfassung zur Seite Nr. 4
SR/SC Series "A" Woodburning Fireplace SR42A Series Woodburning Fireplace 26¹⁄₄" (667mm) Rough Opening Depth 50" (1270mm) 11" Dia. 8¹⁄₄" (279mm) ¹⁄₂" (13mm) 22¹⁄₂" (210mm) (572mm) 8" Dia. 22" (203mm) (559mm) ⁵⁄₈" Recessed (16mm) Nailing Flange Rough Opening Width 47" (1194mm) Rough Opening Height ¹⁄₂" 7¹⁄₂" 43³⁄₄" (191mm) 39⁵⁄₈" (1111mm) (1006mm) Outside Gas Line 22³⁄₄" 7¹⁄₂" Air Access (578mm) 42" (191mm) 24" (1067mm) Gas Line (610mm) Access 14⁵⁄₈" (372mm) 11" 7³⁄₄" (279mm) (197mm) 3" 46"
Inhaltszusammenfassung zur Seite Nr. 5
SR/SC Series "A" Woodburning Fireplace Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. Termination Cap Storm Collar Pan Flashing Batt Insulation (cut out around fiestop) Draftstop Firestop Ceiling Level Standoff Surround Damper Control Nailing Flange Gas Line Knockout (both sides) Gas Line Access (both sides) Screen Grate Electrical Access Firebox Outside Air Cover Plate Metal Safety Strips (1, 2 or 3 pieces) FP554 Fig. 5 Fireplac
Inhaltszusammenfassung zur Seite Nr. 6
SR/SC Series "A" Woodburning Fireplace Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY SECTION IWF282 30˚ ELBOW 30˚ Elbow Offsets RETURN ELBOW B G A 1' 1¹⁄₂' 3' 4' Offset Rise G 30˚ 0000 0 3" 11" OFFSET D 1000 0 8¹⁄₄" 20" ELBOW E RISE 0100 0 11¹⁄₄"25¹⁄₄" 6 FT. 2000 0 13¹⁄₂"29¹⁄₄" SKCS8 30˚ C SUPPORT 1100 0 16¹⁄₂"34¹⁄₄" RETURN H ELBOW 0010 0 20¹⁄₄"40³⁄₄" OFFSET 2100 0 21³⁄₄"43¹⁄₂" 0001 0 26¹⁄₄"51¹⁄₄" 30˚ B OFFSET 0110 0 28¹⁄₂"55¹⁄₄" ELBOW 1001 0 31¹⁄₂"60¹⁄₄”
Inhaltszusammenfassung zur Seite Nr. 7
SR/SC Series "A" Woodburning Fireplace Planning Information Preplanning an installation is very important to ensure 5. No more than 2 offsets (4 total 30° elbows in U.S./ safety and to save time and money. An installer must or 2 total 45° elbows in Canada) per fireplace may predetermine where a fireplace will be set and how the be used. chimney system will be run. 6. A guy wire stabilizer is required for chimneys extending more than 6' (1.8m) above a roof line. Mounting The Fireplace The Ten Fo