Inhaltszusammenfassung zur Seite Nr. 1
Models:
Installers Guide
Pier-TRC
ST-TRC
L-Corner-TRC
R-Corner-TRC
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
WARNING: IF THE INFORMATION
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
WARNING: IMPROPER INSTALLA-
ING PROPERTY DAMAGE, PER- TION, ADJUSTMENT, ALTERATION,
SONAL INJURY, OR DEATH. SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR P
Inhaltszusammenfassung zur Seite Nr. 2
SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of ! ! before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED. in a possible fire hazard and will void the warranty. This gas fireplace and vent assembly MUST be Prior to the first firing of the fireplace, READ the !
Inhaltszusammenfassung zur Seite Nr. 3
TABLE OF CONTENTS Safety and Warning Information ............................................... 2 Service Parts Lists .................................................................... 4 Section 1: Approvals and Codes ............................................ 12 Approval Listings and Codes ..................................................... 12 Appliance Certification ............................................................... 12 Installation Codes ....................................
Inhaltszusammenfassung zur Seite Nr. 4
Pier-TRC Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 6-97 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ 16 9 15 10 Standing Pilot 3 11 1 12 5 4 3 9 14 7 6 2 8 Log Assembly 13 Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. * 4
Inhaltszusammenfassung zur Seite Nr. 5
(NG, LP) Exploded Parts Diagram / Vue éclatée des pièces PIER-TRC IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de mod
Inhaltszusammenfassung zur Seite Nr. 6
ST-TRC Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 6-97 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ 2 7 8 9 10 STANDING PILOT 4 6 1 11 2 5 3 12 Log Assembly 7 Part number list on following page. * La liste des numéros de pièce se trouve * à la page suivante. 6
Inhaltszusammenfassung zur Seite Nr. 7
(NG, LP) Exploded Parts Diagram / Vue éclatée des pièces ST-TRC IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèl
Inhaltszusammenfassung zur Seite Nr. 8
L-Corner-TRC Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 6-97 Ending Manufacturing Date: ______ (GN, PL) Vue éclatée des pièces 10 1 STANDING PILOT 12 8 11 7 5 2 15 6 14 4 9 Log Assembly 3 13 15 Part number list on following page. * La liste des numéros de pièce se trouve * à la page suivante. 8
Inhaltszusammenfassung zur Seite Nr. 9
(NG, LP) Exploded Parts Diagram / Vue éclatée des pièces L-CORNER-TRC IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de
Inhaltszusammenfassung zur Seite Nr. 10
R-Corner-TRC Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 6-97 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ 11 13 10 1 12 STANDING PILOT 7 8 2 5 15 6 14 3 16 4 9 Log Assembly Part number list on following page. * La liste des numéros de pièce se trouve * à la page suivante. 10
Inhaltszusammenfassung zur Seite Nr. 11
(NG, LP) Exploded Parts Diagram / Vue éclatée des pièces R-CORNER-TRC IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et d
Inhaltszusammenfassung zur Seite Nr. 12
Approvals and Codes High Altitude Installations Appliance Certification U.L. Listed gas appliances are tested and approved with- The Heat-N-Glo fireplace models discussed in this Installers out requiring changes for elevations from 0 to 2,000 feet in Guide have been tested to certification standards and listed the U. S. A. and in Canada. by the applicable laboratories. When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input rating by Certificati
Inhaltszusammenfassung zur Seite Nr. 13
Getting Started Introducing the Heat-N-Glo Gas Fireplaces The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo disclaims any responsibility for, the following actions: Heat-N-Glo direct vent gas fireplaces are designed to oper- • Installation of any damaged fireplace or vent system ate with all combustion air siphoned from outside of the component. building and all exhaust gases expelled to the outside. • Modification of the fireplace or direct vent system. The information contained in this
Inhaltszusammenfassung zur Seite Nr. 14
13 (331mm) 24 1/4 (616mm) 12 1/8 (308mm) VENT COLLARS 42 3/4 (1086mm) ELECTRICAL ACCESS GAS LINE 41 ACCESS (1043mm) 36 7/8 (937mm) 28 7/8 (735mm) 2 1/2 2 1/2 (64mm) (6mm) 36 7/8 (937mm) 24 1/4 (616mm) 4 (102mm) 4 (102mm) 40 3/4 (1035mm) LEFT SIDE FRONT RIGHT SIDE TOP STANDOFFS TOP VENT COLLARS REAR COLLARS TOP GRILLE SIDE GLASS DOOR END GLASS DOOR BOTTOM GRILLE GAS CONTROLS & LABELS ELECTRICAL GAS LINE ACCESS ACCESS Figure 1. Diagram of the PIER-TRC 14
Inhaltszusammenfassung zur Seite Nr. 15
45 (1143mm) 13 (330mm) 24 1/4 (616mm) 12 1/8 (308mm) VENT COLLARS 41 ELECTRICAL (1042mm) GAS LINE ACCESS ACCESS 36 7/8 (937mm) 28 7/8 (733mm) 2 1/2 2 1/2 (64mm) (64mm) 36 1/8 (918mm) 4 (102mm) 4 (102mm) 43 (1093mm) 24 1/4 (616mm) FRONT LEFT SIDE RIGHT SIDE TOP VENT COLLARS REAR VENT COLLARS TOP STANDOFFS TOP GRILLE GLASS DOOR BOTTOM GRILLE GAS CONTROLS & LABELS ELECTRICAL GAS LINE ACCESS ACCESS Figure 2. Diagram of the ST-TRC 15
Inhaltszusammenfassung zur Seite Nr. 16
42 3/4 (1086mm) 13 (330mm) 25 1/4 (642mm) 12 1/8 (308mm) VENT COLLARS 41 (1041mm) ELECTRICAL GAS LINE 28 7/8 ACCESS ACCESS (733mm) 36 7/8 (937mm) 2 1/2 2 /12/ (64mm) (64mm) 36 1/8 (918mm) 4 (102mm) 4 (102mm) 24 1/4 (616mm) 40 3/4 (1034mm) LEFT SIDE FRONT RIGHT SIDE TOP VENT COLLARS REAR VENT COLLARS TOP STANDOFFS TOP GRILLE SIDE GLASS DOOR END GLASS DOOR BOTTOM GRILLE GAS CONTROLS & LABELS GAS LINE ACCESS ELECTRICAL ACCESS Figure 3. Diagram of the L & R CORNER-TRC 16
Inhaltszusammenfassung zur Seite Nr. 17
Installing the Fireplace Step 1. Locating the Fireplace Minimum Clearances The diagram below shows space and clearance require- from the Fireplace to Combustible Materials ments for locating a fireplace within a room. Inches mm Glass Sides or Ends .......... 36 ..................... 914 Floor ....................................0 ........................ 0 Rear Vent ............................1 ....................... 25 GLASS GLASS Metal Sides or Ends .......... 1/2 ....................
Inhaltszusammenfassung zur Seite Nr. 18
Shows center of 12” x 12” vent framing holes for top and rear venting. The center of the hole is CORNER-TRC'S one inch (25.4mm) above the center of the horizontal vent pipe. B E D A C Framing should be constructed of 2 X 4 lumber or heavier. ST-TRC PIER-TRC CORNER-TRC'S B B C A A C Model A B C D E VENTED VENTED TOP REAR PIER-TRC 43 1/4 40 1/4 41 1/2 23 1/4 45 29 7/8 ST-TRC 47 46 41 1/2 23 1/4 45 29 7
Inhaltszusammenfassung zur Seite Nr. 19
(164mm) (216mm) m (295 m) 11 1/16” 5 1/16” (187mm) 8 5/8” 6 ” 7/16 8 1/2” (216mm) 6 5/32” 8 1/2” (1 m) 56m 11 5/8” 7 3/8” 5 7/8” 1/2 6 ” (149mm) (281mm) (165mm) 129 ) ( mm (220mm) 5 11 1 /16” (303mm) D V-90D DV-36D DV-48D 8 5/8” (220mm) DV-45D 35 3/4” 47 3/4” (908mm) (1.2m) 11 3/4” (298mm) 8 3/4” 5 3/4” (222mm) (146mm) DV-12D DV-09D DV-06D NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOINT. Figure 6. D-Series Direct Vent Component Specifications (5-inch inner pipe / 8 5/8-inch outer pi
Inhaltszusammenfassung zur Seite Nr. 20
Step 3. Installing the Vent System Identifying Vent Components The vent systems installed on this gas fireplace may in- A. Vent System Approvals clude one, two, or three 90° elbow assemblies. The rela- These models are approved to use D-series direct vent pipe tionships of vertical rise to horizontal run in vent configura- components and terminations (see Figures 6 and 7). Ap- tions using 90° elbows MUST BE strictly adhered to. The proved vent system components are labeled for identifica- ri